• Title/Summary/Keyword: orthodontic materials

Search Result 183, Processing Time 0.028 seconds

A case of full mouth rehabilitation with orthodontic treatment in patient with extensive tooth erosion and wear using monolithic zirconia prostheses (광범위한 치아부식 및 마모가 있는 환자에서 교정치료와 단일구조 지르코니아 보철물을 이용하여 완전 구강 회복술을 시행한 증례)

  • Yun, Byoung Soo;Kim, Jong Eun;Shim, Jun Sung;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.360-367
    • /
    • 2018
  • Extensive dental erosion and wear will cause serious loss of function and aesthetics in the mouth. In order to recover this condition, careful analysis of the patient's bite relationship is required. In particular, a treatment plan should be established considering the possibility of reproduction of the vertical dimension and centric relation, and appropriateness of the occlusal plane and anterior guidance. Also, the choice of prosthetic materials is an important consideration in patients with severe wear. In this case, patients with overall wear and erosion on tooth was established anterior guidance by orthodontic treatment and fully restored with monolithic zirconia, without increasing vertical dimension.

Research on characteristics and treatment duration and method of patients with tooth impaction who visited Gachon University Gil Hospital Orthodontic Department (year 2005-2008) (가천의대 길병원 교정과에 내원한 매복치 환자의 특성과 치료기간 및 방법에 관한 연구(2005년~2008년))

  • Moon, Cheol-Hyun;Kang, Hyun-Wook;Choi, Jin-Hugh
    • The Journal of the Korean dental association
    • /
    • v.49 no.4
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: An impacted tooth is defined as a tooth that shows delayed eruption and is expected to erupt incompletely by clinical and radiograph examination despite it reaching its expected time of eruption. The aims of this study were to investigate the clinical and radiological characteristics and treatment duration and method of impacted teeth in Korean patients. Materials and Methods: For this study we used clinical records, study models, panoramic radiographs and intraoral photographs of patients who attended Gachon University Gil Hospital Orthodontic Department between 2005 and 2008. There were 164 patients with a total number of 202 impacted teeth. Results: Male patients shows a little more prevalence than female patients (1.13:1). The under 12 age group had the highest prevalence of tooth impaction, and the over 19 age group showed the least prevalence of tooth impaction. The ratio of tooth impaction between the left to right ratio was 1.73:1 and maxilla and mandible was 1.84:1. The impacted teeth were most commonly positioned buccally (76 cases, 41.5%). Full nap closure technique (108 cases, 81.2%)was most frequently used for attachment of surgical traction hooks. Maxillary canine impaction was most commonly encountered both in male and female patients. The mean treatment period was 12.2 months and the success rate of treatment was 90.3%. The canine tooth shows the longest treatment time and highest failure rate. The ankylosis was the major cause of failure. Conclusion: Impacted teeth most commonly show in left side maxilla in the under 12 age group. And it is most commonly positioned buccally. The mean treatment period was 12.2 months, and the success rate of treatment was 90.3%.

Effect of rotation bump on removal torque of orthodontic mini-implants

  • Gansukh, Odontuya;Jeong, Jong-Wha;Kim, Jong-Wan;Kim, Young-Kyun;Lee, Jong-Ho;Kim, Tae-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.6
    • /
    • pp.269-273
    • /
    • 2013
  • Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirty-two mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.

A STUDY OF SHEAR BOND STRENGTH AND FAILURE PATTERNS IN LIGHT-AND SELF-CURED ORTHODONTIC RESIN (교정용 광중합형 및 화학중합형 레진접착제의 전단결합강도와 파절양상에 대한 연구)

  • Lee, Min-Ha;Yang, Kyu-Ho;Park, Yeong-Joon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.549-558
    • /
    • 1996
  • Light-cured orthodontic composite resin has been widely advertised recently for use in bonding brackets. However, the curability of light-cured resin when light waves are diffused through metal brackets in questionable. The purposes of this study were to evaluate shear bond strength and failure patterns of visible light-cured resin(Lightbond) and chemically cured-resin(Mono-Lok 2), and to determine the relative value of light-cured resin as an alternative to conventional chemically cured resin. Each of the two resins was tested on twenty extracted human first premolars. Standard edgewise metal brackets were bonded to the teeth in accordance with the manufacturers' recommendation. After bonding, the teeth were stored for 24 hours at $37^{\circ}C$, 100% humidity. The shear bond strength was tested with a universal testing machine(Instron 4302), at 0.5mm/min crosshead speed. After debonding, brackets and enamel surfaces were examined with a scanning electron microscope and a stereoscopic microscope. The results were as follows : 1. Metal brackets bonded with Lightbond showed statistically higher shear bond strength than metal brackets bonded with Mono-Lok2. 2. The predominant failure site in Lightbond was the enamel-resin interface, and in Mono-Lok 2 it was the resin itself. 3. Enamel cracks were not found in any specimen. The above results suggest that direct bonding of metal brackets to enamel with light-cured resin bonding agent can be used effectively in clinics.

  • PDF

Effect of Laser Pre-Drilling on Insertion Torque of Orthodontic Miniscrews: A Preliminary Study

  • Kim, Keun-Hwa;Choi, Sung-Hwan;Cha, Jung-Yul;Hwang, Chung-Ju
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.66-73
    • /
    • 2017
  • Purpose: To evaluate the effect of different-sized drill tips and laser irradiation times on the initial stability of orthodontic miniscrews placed in Er,Cr:YSGG-laser pre-drilled holes in an animal model. Materials and Methods: Laser pre-drilled holes were made in dog mandibular bone with an Er,Cr:YSGG laser using irradiation times of 5, 7, 9, 11, and 13 seconds, and tip diameters of 0.4 and 0.6 mm. The maximum diameter and depth of the pre-drilled holes was measured with micro computed tomography. The maximum insertion torque was measured during placement the miniscrew. Result: Laser pre-drilled holes were conical shaped. The maximum diameter of pre-drilled holes increased with longer laser irradiation times (P>0.05) and larger tip diameters (P<0.05). The depth of pre-drilled holes increased with longer laser irradiation times and larger tip diameters (P<0.05). When the 0.4 mm tip, but not the 0.6 mm tip, was used, the insertion torque decreased significantly with longer laser irradiation times (P<0.05). Conclusion: Tip diameter impacted insertion torque more than irradiation time. It takes at least 9 seconds using a 0.6 mm tip to create a 0.8 mm diameter and 1.0 mm depth hole in thick cortical bone.

Bone changes in the mandibular incisors after orthodontic correction of dental crowding without extraction: A cone-beam computed tomographic evaluation

  • Valerio, Claudia Scigliano;Cardoso, Claudia Assuncao e Alves;Arauujo, Eustaquio Afonso;Zenobio, Elton Goncalves;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.155-165
    • /
    • 2021
  • Purpose: This study aimed to evaluate changes of the alveolar bone and interdental bone septum of the mandibular incisors through cone-beam computed tomography (CBCT) after orthodontic treatment of mandibular dental crowding without dental extraction. Materials and Methods: The sample consisted of 64 CBCT images(32 pre-treatment and 32 post-treatment) from 32 adult patients with class I malocclusion and an average age of 23.0±3.9 years. The width and height of the alveolar bone and interdental septum, the distance between the cementoenamel junction (CEJ) and the facial and lingual bone crests, and the inclination of the mandibular incisors were measured. Results: The distance between the CEJ and the marginal bone crest on the facial side increased significantly (P<0.05). An increased distance between the CEJ and the bone crest on the facial and lingual sides showed a correlation with the irregularity index (P<0.05); however, no significant association was observed with increasing mandibular incisor inclination (P>0.05). The change in the distance between the CEJ and the marginal bone crest on the facial side was correlated significantly with bone septum height(P<0.05). Conclusion: Bone dehiscence developed during the treatment of crowding without extraction only on the incisors' facial side. Increasing proclination of the mandibular incisor was not correlated with bone dehiscence. The degree of dental crowding assessed through the irregularity index was associated with the risk of developing bone dehiscence. The interdental septum reflected facial marginal bone loss in the mandibular incisors.

Surface Characteristics of Polymer Coated NiTi Alloy Wire for Orthodontics (폴리머 코팅된 NiTi합금 교정선의 표면특성)

  • Cho, Joo-Young;Kim, Won-Gi;Choi, Hwan-Suk;Lee, Ho-Jong;Choe, Han-Cheol
    • Journal of Surface Science and Engineering
    • /
    • v.43 no.3
    • /
    • pp.132-141
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate surface characteristics of polymer coated NiTi alloy wire for orthodontics using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with field emission scanning electron microscopy(FE-SEM), energy dispersive x-ray spectroscopy(EDS) and atomic force microscopy(AFM). The phase transformation of non-coated NiTi wire from martensite to austenite occurred at the range of $14{\sim}15^{\circ}C$, in the case of coated wire, it occurred at the range of $16{\sim}18^{\circ}C$. Polymer coating on NiTi wire surface decreased the surface defects such as scratch which was formed at severe machined surface. From the AFM results, the average surface roughness of non-coated and coated NiTi wire was 13.1 nm, and 224.5 nm, respectively. From convetional surface roughness test, the average surface roughness of non-coated and coated NiTi wire was $0.046{\mu}m$, and $0.718{\mu}m$, respectively.

Autogenous transplantation of tooth with complete root formation (치근단 완성된 치아의 자가이식)

  • Lee, Sul-Hyun;Son, Mee-Kyoung;Park, Ji-Il;Kim, Ok-Su;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.709-716
    • /
    • 2008
  • Purpose: Autogenous transplantation of teeth can be defined as transplantation of teeth from one site to another in the same individual, involving transfer of impacted or erupted teeth into extraction sites or surgically prepared sockets". Successful autogenous transplantation of teeth depends upon a complex variety of factors. Such factors include damage to the periodontal ligament of the donor tooth, residual bone height of the recipient site, extra-oral time of tooth during surgery. Schwartz and Andreasen previously reported that autogenous transplantation of teeth with incomplete root formation demonstrated higher success rate than that of teeth with complete root formation. Gault and Mejare yielded similar rate of successful autogenous transplantation both in teeth with complete root formation and in teeth with incomplete root formation when appropriate cases were selected. This case report was aimed at the clinical and radiographic view in autogenous transplantation of teeth with complete root formation. Materials and Methods: Patients who presented to the department of periodontics, Chonnam National University Hospital underwent autogenous transplantation of teeth. One patient had vertical root fracture in a upper right second molar and upper left third molar was transplanted. And another patient who needed orthodontic treatment had residual root due to caries on upper right first premolar. Upper right premolar was extracted and lower right second premolar was transplanted. Six months later, orthodontic force was applied. Results: 7 months or 11/2 year later, each patient had clinically shallow pocket depth and normal tooth mobility. Root resorption and bone loss were not observed in radiograph and function was maintained successfully. Conclusion: Autogenous transplantation is considered as a predictive procedure when it is performed for the appropriate indication and when maintenance is achieved through regular radiographic taking and follow-up.

Surface roughness and surface free energy components of various orthodontic adhesives (다양한 교정용 접착제의 표면거칠기와 표면에너지 요소 분석)

  • Ahn, Hyo-Beom;Ahn, Sug-Joon;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.360-368
    • /
    • 2006
  • Objective: Surface characteristics of dental materials play an important role in bacterial adhesion. The purpose of this study was to investigate surface characteristics of 5 different light-cured orthodontic adhesives (1 fluoride-releasing composite, 3 non-fluoride-releasing composites, and f resin-modified glass ionomer). Methods: Surface roughness was measured using a confocal laser scanning microscope. Contact angle and surface free energy components were analyzed using the sessile drop method. Results: Surface roughness was significantly different between adhesives despite a relatively small variation (less than $0.05\;{\mu}m$). Lightbond and Monolok2 were rougher than Enlight and Transbond XT. There were also significant differences in contact angles and surface free energy components between adhesives. In particular, considerable differences in contact angles and surface free energy components were found between resin modified glass ionomer and the composites. Resin modified glass ionomer showed significantly smaller contact angles in 3 different probe liquids and had higher total surface free energy and stronger polarity, with notably stronger basic property than the composites. Conclusion: Resin modified glass ionomer may provide a more favourable environment for bacterial adhesion than composite adhesives.

Changes in pulpal blood flow during orthodontic tooth movement studied by Doppler ultrasound (Doppler ultrasound를 이용한 교정적 치아 이동 시 치수 혈류량의 변화의 측정- 예비실험)

  • Lim, Kyoung-Sub;Bae, Young-Min;Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.372-382
    • /
    • 2009
  • Objective: This study was to change of pulp blood flow among maxillary and mandibular anterior tooth with mild crowding and adjacent teeth using Ultrasound Doppler graphy. Methods: The change of pulp blood flow was measured three times using Ultrasound Doppler graphy; before the attachment of brackets, after 3 week, and after 6 week. The sample consists of 15 year old eighteen patients. Results: Before the attachment of brackets, after 3 weeks, and after 6 weeks, there were no significant differences in the change of pulp blood flow in each part (maxilla and mandible) and each tooth according to period. In addition, to compare internal dangerousness of loss of the pulp vitality, when pulp blood flow is compared in each tooth before orthodontic treatment, there were no statistically significant differences in maxillary lateral incisor and mandibular canine but it showed low values in all measurement items (p > 0.05). Conclusions: Results of this study can be not only methodological preliminary data in further study such as tooth movement type of Ultrasound Doppler graphy and particular study considered the patient age, but also reference materials for the loss of pulp vitality in orthodontic treatment.