Study of a "wing-type" implant on stress distribution and bone resorption at the alveolar crest

  • Park, Jong-Wook;Kim, Sin-Guen;Choi, Dong-Won;Choi, Mi-Ra;Yoon, Youn-Jin;Park, Jun-Woo;Choi, Dong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권6호
    • /
    • pp.337-342
    • /
    • 2012
  • Objectives: Implants connect the internal body to its external structure, and is mainly supported by alveolar bone. Stable osseointegration is therefore required when implants are inserted into bone to retain structural integrity. In this paper, we present an implant with a "wing" design on its area. This type of implant improved stress distribution patterns and promoted changes in bone remodeling. Materials and Methods: Finite element analysis was performed on two types of implants. One implant was designed to have wings on its cervical area, and the other was a general root form type. On each implant, tensile and compressive forces ($30N/m^2$, $35N/m^2$, $40N/m^2$, and $45N/m^2$) were loaded in the vertical direction. Stress distribution and displacement were subsequently measured. Results: The maximum stresses measured for the compressive forces of the wing-type implant were $21.5979N/m^2$, $25.1974N/m^2$, $29.7971N/m^2$, and $32.3967N/m^2$ when $30N/m^2$, $35N/m^2$, $40N/m^2$, and $45N/m^2$ were loaded, respectively. The maximum stresses measured for the root form type were $23.0442N/m^2$, $26.9950N/m^2$, $30.7257N/m^2$, and $34.5584N/m^2$ when $30N/m^2$, $35N/m^2$, $40N/m^2$, and $45N/m^2$ were loaded, respectively. Thus, the maximum stresses measured for the tensile force of the root form implant were significantly higher (about three times greater) than the wing-type implant. The displacement of each implant showed no significant difference. Modifying the design of cervical implants improves the strength of bone structure surrounding these implants. In this study, we used the wing-type cervical design to reduce both compressive and tensile distribution forces loaded onto the surrounding structures. In future studies, we will optimize implant length and placement to improve results. Conclusion: 1. Changing the cervical design of implants improves stress distribution to the surrounding bone. 2. The wing-type implant yielded better results, in terms of stress distribution, than the former root-type implant.

백서에 식립한 치과용 임플란트의 골유착에 흡연이 미치는 영향 (INFLUENCE OF CIGARETTE SMOKE INHALATION ON DENTAL IMPLANT OSSEOINTEGRATION IN THE RAT)

  • 김세호;김성민;김지혁;박영욱;박찬진;정기명;이석근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권4호
    • /
    • pp.291-299
    • /
    • 2005
  • Objectives : It is well known that cigarette smoking is harzardous to the osseointegration of dental implant, due to the impaired wound healing accompanied by reduced alveolar bone density. The aim of this study is to evaluate the influence of cigarette smoke on the implant osseointegration by the time factor consideration. Materials and methods : Twenty-four male Spraque-Dawley rats (8 weeks, weighting 200 to 250g) were used in this study. In the experimental group, 13 rats were exposed to cigarette smoke, 8 minutes per day during 6 weeks, and 12 rats in the control group were not exposed at any time. RBM (Resorbed blasting media) surfaced implant (diameter 3.3mm, length 5.0mm, AVANA Co., Korea) was placed in the right femur of each rat. Each implant with surrounding bone was prepared with microtome (cutting band 0.2mm$^{(R)}$, EXAKT Co., Germany) after 1 day, 2, 4, 8 and 12 weeks and stained with toluidine blue (1%). Another clinical investigation of each implant was also done at each evaluation time. Results : Clinical investigation around implant fixture showed that there were no significant differences between the control and experimental group. Microscopic observation around implant fixture showed that there were significant differences between the control and experimental group at the initial stage after implant fixture installation. Experimental group showed a decreased bone to implant contact within 4 weeks compared to control group, but showed similar characteristics after 4 weeks. Conclusion : Smoking inhalation effect on the dental implant showed the impaired wound healing by vasoconstriction and decreased intramedullary blood flow at initial stage of osseointegration. This experimental results can be clinically useful to the implant surgery of smoking patients.

Sensory change after implant surgery: related factors for recovery

  • Jung, Joon-Ho;Ko, Ji-Hoon;Ku, Jeong-Kui;Kim, Jae-Young;Huh, Jong-Ki
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권5호
    • /
    • pp.297-302
    • /
    • 2022
  • Objectives: This retrospective study aimed to analyze data on nerve damage in patients who complained of sensory changes after dental implant surgery, the clinical results according to proximity of the implant fixture to the inferior alveolar nerve (IAN) canal, and the factors affecting recovery of sensation. Materials and Methods: The electronic medical records of 64 patients who had experienced sensory change after implant surgery were reviewed. Patients were classified by sex, age, implant installation sites, recovery rate and the distance between the implant fixture and IAN canal on computed tomography (CT). The distance was classified into Group I (D>2 mm), Group II (2 mm≥D>0 mm), and Group III (D≤0 mm). Results: The 64 patients were included and the mean age was 57.3±7.3 years. Among the 36 patients who visited our clinic more than two times, 21 patients (58.3%) reported improvement in sensation, 13 patients (36.1%) had no change in sensation, and 2 patients (5.6%) reported worsening sensation. In Group II, symptom improvement was achieved in all patients regardless of the removal of the implant fixture. In Group III, 8 patients (40.0%) had reported symptom improvement with removal of the implant fixture, and 2 patients (33.3%) of recovered patients showed improvement without removal. Removal of the implant fixture in Group III did not result in any significant difference in recovery (P=0.337), although there was a higher possibility of improvement in sensation in removal cases. Conclusion: Clinicians first should consider removing the fixture when it directly invades the IAN canal. However, in cases of sensory change after dental implant surgery where the drill or implant fixture did not invade the IAN canal, other indirect factors such as flap elevation and damage due to anesthesia should be considered as causes of sensory change. Removal of the implant should be considered with caution in these situations.

Prognosis following dental implant treatment under general anesthesia in patients with special needs

  • Kim, Il-hyung;Kuk, Tae Seong;Park, Sang Yoon;Choi, Yong-suk;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권3호
    • /
    • pp.205-213
    • /
    • 2017
  • Background: This study retrospectively investigated outcomes following dental implantation in patients with special needs who required general anesthesia to enable treatment. Method: Patients underwent implant treatment under general anesthesia at the Clinic for the Disabled in Seoul National University Dental Hospital between January 2004 and June 2017. The study analyzed medical records and radiographs. Implant survival rates were calculated by applying criteria for success or failure. Results: Of 19 patients in the study, 8 were males and 11 were females, with a mean age of 32.9 years. The patients included 11 with mental retardation, 3 with autism, 2 with cerebral palsy, 2 with schizophrenia, and 1 with a brain disorder; 2 patients also had seizure disorders. All were incapable of oral self-care due to serious cognitive impairment and could not cooperate with normal dental treatment. A total of 27 rounds of general anesthesia and 1 round of intravenous sedation were performed for implant surgery. Implant placement was performed in 3 patients whose prosthesis records could not be found, while 3 other patients had less than 1 year of follow-up after prosthetic treatment. When the criteria for implant success or failure were applied in 13 remaining patients, 3 implant failures occurred in 59 total treatments. The cumulative survival rate of implants over an average of 43.3 months (15-116 months) was 94.9%. Conclusion: For patients with severe cognitive impairment who are incapable of oral self-care, implant treatment under general anesthesia showed a favorable prognosis.

접촉 유한요소모델을 이용한 미니 임플란트의 초기 응력분포 연구 (Contact non-linear finite element model analysis of initial stability of mini implant)

  • 윤현주;정의원;이종석;김창성;김정문;조규성;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.681-690
    • /
    • 2007
  • Mini implants had been used provisionally for the healing period of implants in the beginning. But it becomes used for the on-going purpose, because it is simple to use, economic and especially suitable for the overdenture. But there is few studies about the stability of mini implants, that is most important factor for the on-going purpose, and particularly the implant parameters affecting the initial stability. The purpose of this study was to evaluate the stress and the strain distribution pattern of immediate-loaded screw type orthodontic mini-implant and the parameters affecting the initial stability of immediate-loaded mini-implant. Two dimensional finite element models were made and contact non-linear finite element analysis was performed. The magnitude and distribution of Von Mises stresses were evaluated. The obtained results were as follows: 1. The stress was concentrated on the thread tip of an implant in the cortical bone. 2. The direction of load is the most important factor for the stress distribution in cortical bone. 3. The diameter of an implant is the most important factor for the stress distribution in the trabecular bone. In conclusion, if the horizontal load vector is successfully controlled, mini-implants, which diameter is under 3mm, can be used for the on-going purpose.

A 10-year follow-up study on clinical outcomes of dental implant rehabilitation using surgical guide

  • Haoyun Li;Mi Young Eo;Kezia Rachellea Mustakim;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제50권2호
    • /
    • pp.70-79
    • /
    • 2024
  • Objectives: The surgical guide is a static computer-assisted device used for implant surgery planning and guidance. By taking an impression and referring to the patients' three-dimensional computed tomography scan of the desired implant site, a surgical guide can be created. During surgery, the surgical guide aids in achieving the designed implant placement position and direction. We examined and evaluated the long-term clinical outcomes of implant surgery using surgical guides. Materials and Methods: This study investigated a total of 15 patients with 32 implants that were placed using surgical guides from 2009 to 2011 with a mean follow-up period extended beyond 10 years. Patient demographics and implant survival rates were recorded. We analyzed marginal bone loss (MBL) by assessing the radiographs acquired at installation, three months after installation, and one month, one, two, and five years after prosthesis delivery. Results: The mean patient age was 57.33 years at implant placement. Of the 32 implants, five implants were placed in the anterior region and 27 implants were in the posterior region. Six implants failed and three of them were replaced, resulting in an 81.25% survival rate. The mean follow-up period was 10 years and nine months. Mean MBL compared to post-installation was significantly higher than at three months after installation, and one month, one, two, and five years after prosthesis delivery. Mean MBL at three months after installation, and one month, one year, and two years were significantly higher compared to the previous visit (P<0.05). However, MBL at five years after prosthesis delivery did not differ significantly compared to at two years. Conclusion: In this study, implant rehabilitation assisted by surgical guides exhibited favorable survival rates. With the limitation of the sample amount in this study, further research and more samples are required to evaluate the long-term clinical effectiveness of surgical guides.

임프란트 식립오류가 최종 보철물의 성공에 미치는 영향: 구강악안면외과의사에 의해 식립된 치과임프란트에 대한 보철의사의 주관적 평가 (Influence of implant misplacement on the success of the final prosthesis: Subjective evaluation by a prosthodontist of dental implants placed by an oral and maxillofacial surgeon)

  • 김영균;황정원;이효정;여인성;윤필영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권6호
    • /
    • pp.437-441
    • /
    • 2009
  • Purpose: In many cases, the erroneous placement of a dental implant brings about undesirable results. Here, the effect of dental implant placement on the success of the final prosthesis was evaluated from the point of view of the prosthodontist. Materials and Methods: All surgical operations were performed by the same oral surgeon with the same surgical protocol and all prosthodontic procedures were performed by the same prosthodontist. The problems faced by the prosthodontist, their causes, and their effect on prosthesis success were identified. The success of the final prostheses was evaluated by the same prosthodontist. Results: Only 53% (238 implants in 105 patients) of dental implants were not associated with prosthodontic problems. Multiple implant placement (more than three implants) was associated more frequently with prosthodontic problems. Conclusions: The data indicate that the satisfactory construction of a prosthesis is highly dependent on the placement of the dental implant in the best possible position. It is strongly recommended that the oral surgeon and the prosthodontist engage in pre-operative discussions to establish a top-down treatment plan, as this will improve implant placement and ultimately the success of the prosthesis.

임플란트 보유자의 구강보건관리행태 (Behavior and attitude toward oral health care in implant wearers)

  • 강부월;이선미
    • 한국치위생학회지
    • /
    • 제14권6호
    • /
    • pp.887-894
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the oral health education and oral health care in the implant wearers. Methods: A self-administered questionnaire was conducted by 253 patients in 14 different dental hospitals and clinics in Seoul and Gyeonggi-do from July 1 to September 30, 2012. The instrument was adapted from Kang and Lee, Yu and Shim, and Ko and Jang on the basis of the previous study. The questionnaire consisted of 12 questions including general characteristics of the subjects(4 questions), oral health education(3 questions), behavior and attitude of tooth brushing(3 questions), and use of auxiliary supplies(2 questions). Results: 1. 38.3% of the patients received the dental care education for the first time. The most common education method was demonstration by dental hygienists(28.9%). 26.2% of the patients wanted to know the right toothbrushing method. 2. The best toothbrushing methods were rolling method(28.9%) and Leonard's method(28.9%). 19.4% of the patients changed the toothbrushing method after education. 22.5 percent brushed their natural teeth and implant teeth by a different maneuver. 3. The interdental brush was the most commonly used product(35.8%) and most of the patients the interdental brush once a day(36.6%). 4. There was a significant difference between the frequency of toothbrushing and method(p<0.05). 5. There was a significant difference between the separate brushing of implant and natural teeth by the frequency of toothbrushing and method of education(p<0.05). 6. Use of interdental brush had an influenced on education method(p<0.05). Conclusions: Regular dental checkup and use of interdental brush can improve the oral care for the implant wearers. Regular use of interdental brush can prolong the life span of implant tooth and keep the patients' teeth in good condition.

Proton pump inhibitor intake negatively affects the osseointegration of dental implants: a retrospective study

  • Altay, Mehmet Ali;Sindel, Alper;Ozalp, Oznur;Yildirimyan, Nelli;Kocabalkan, Burak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권3호
    • /
    • pp.135-140
    • /
    • 2019
  • Objectives: This study sought to investigate the association between the systemic intake of proton pump inhibitors (PPI) and the early failure of dental implants. Materials and Methods: A retrospective cohort study involving 1,918 dental implants in 592 patients (69 implants in 24 PPI users and 1,849 implants in 568 nonusers, respectively) was conducted. The effect of PPI intake on the osseointegration of dental implants was evaluated using patientand implant-level models. Results: Among 24 PPI users, two patients experienced implant failure, one of whom had three and the other of whom had one failed implant, respectively. Thus, the rate of failure for this population was 8.3%. Separately, 11 nonusers each experienced one implant failure, and the failure rate for these patients was 1.9%. Fisher's exact test revealed statistically significant differences between PPI users and nonusers at the implant level (P=0.002) but failed to show any significance at the patient level (P=0.094). The odds of implant failure were 4.60 times greater among PPI users versus nonusers. Dental implants that were placed in patients using PPIs were found to be 4.30 times more likely to fail prior to loading. Conclusion: The findings of this study suggest that PPI intake may be associated with an increased risk of early dental implant failure.

Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments

  • Gehrke, Peter;Riebe, Oliver;Fischer, Carsten;Weinhold, Octavio;Dhom, Gunter;Sader, Robert;Weigl, Paul
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권5호
    • /
    • pp.273-284
    • /
    • 2022
  • PURPOSE. Computer-aided design and manufacturing (CAD-CAM) of implant abutments has been shown to result in surface contamination from site-specific milling and fabrication processes. If not removed, these contaminants can have a potentially adverse effect and may trigger inflammatory responses of the peri-implant tissues. The aim of the present study was to evaluate the bacterial disinfection and cleaning efficacy of ultrasonic reprocessing in approved disinfectants to reduce the microbial load of CAD-CAM abutments. MATERIALS AND METHODS. Four different types of custom implant abutments (total N = 32) with eight specimens in each test group (type I to IV) were CAD-CAM manufactured. In two separate contamination experiments, specimens were contaminated with heparinized sheep blood alone and with heparinized sheep blood and the test bacterium Enterococcus faecium. Abutments in the test group were processed according to a three-stage ultrasonic protocol and assessed qualitatively and quantitatively by determination of residual protein. Ultrasonicated specimens contaminated with sheep blood and E. faecium were additionally eluted and the dilutions were incubated on agar plates for seven days. The determined bacterial counts were expressed as colony-forming units (CFU). RESULTS. Ultrasonic reprocessing resulted in a substantial decrease in residual bacterial protein to less than 80 ㎍ and a reduction in microbiota of more than 7 log levels of CFU for all abutment types, exceeding the effect required for disinfection. CONCLUSION. A three-stage ultrasonic cleaning and disinfection protocol results in effective bacterial decontamination. The procedure is reproducible and complies with the standardized reprocessing and disinfection specifications for one- or two-piece CAD-CAM implant abutments.