• 제목/요약/키워드: optimum ventilation system

검색결과 66건 처리시간 0.02초

객차용 가스처리장치 개발 (Development of Gas Treatment System for Passenger Cabins)

  • 이주열;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1302-1306
    • /
    • 2007
  • Malfunction or inappropriate management of ventilation system in public transportation may cause unpleasant atmosphere or health problems to the old or feeble passengers. In this work, adsorption/desorption system for gaseous carbon dioxide is developed and tested under the various indoor conditions. Finally an optimum design specification for the indoor $CO_2$ control will presented.

  • PDF

환기시스템의 굴절 및 평판형 열교환기 형상에 따른 성능비교 (A Comparison of Performance on the Orthogonal and Refraction Heat Exchanger Shape in Air Ventilation System)

  • 현형호;정병호;김지원;이강연
    • 한국융합학회논문지
    • /
    • 제10권7호
    • /
    • pp.281-287
    • /
    • 2019
  • 최적의 환기시스템 활용과 에너지 절약을 위한 급 배기공기 간의 열교환을 적용시킨 열회수시스템의 활용과 보급은 에너지관리시스템에서 필수적이다. 이러한 기술은 특히, 겨울철과 여름철의 냉난방에너지를 절약할 수 있어 고효율에너지 빌딩의 기반기술의 주요 요소이다. 본 논문에서는 균일한 형상과 동일한 유동조건에서 열교환기 성능을 비교하기 위해 종이, 플라스틱, 알루미늄을 재질로 시뮬레이션을 통한 열전달효율을 검토하였다. 또한 평판형과 굴절형 구조를 갖는 열교환기의 형상에 따른 열전달 효율을 시험하였고, 그 결과를 토대로 열전달 성능과 압력손실에 대해 고성능의 열교환기를 제작하는데 기여를 할 수 있을 것으로 기대된다.

소규모 음압터널환기방식 무창자돈사의 최적 환기 요건에 관한 연구 (Necessary Conditions for Optimal Ventilation of Small Windowless Piglet House with Negative Tunnel Ventilating System)

  • 이승주;장동일;;박정식;전상훈;조형제;오권영;장홍희
    • Journal of Biosystems Engineering
    • /
    • 제34권1호
    • /
    • pp.63-68
    • /
    • 2009
  • This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (5.2 (W) ${\times}$ 12.3 (L) ${\times}$ 2.3 (H) m) with negative tunnel ventilating system using CFD (Computational Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 4 rooms (520 (W) ${\times}$ 300 (L) cm), 3 fences (70 (H) cm), 1 air inlet (350 (W) ${\times}$ 2 (H) cm) and 1 exhaust fan (50 (D) cm), and simulated using CFD code, FLUENT. The simulation results for the original weaning piglet house showed ununiform ventilation for each room. Therefore, to uniformly ventilate all rooms, the heights of the air inlet and first fence were modified to 3 cm and 100 cm, respectively. The simulation result f3r the modified weaning piglet house showed uniform ventilation for all rooms and the optimum air inlet velocity of 1.4 m/s.

원자력시설의 공기조화 시스템 고찰 (Study on HVAC System in Nuclear Facility)

  • 백상열;송웅섭;오연우;주용선;홍권표
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.503-508
    • /
    • 2003
  • 원자력 시설의 공기조화 시스템은 일반시설의 공기조화 시스템에 비하여 더 안정되고 여유있게 설치 및 시공되어야 한다. 그 목적은 최적 작업환경유지, 오염 공기로부터의 작업자 보호, 외부배기로 인한 대기오염 방지 등이다. 낮은 공기오염조차 막는 것이 원자력시설의 안전한 운전을 위해 기본적인 것이다. 설계 시 시스템의 융통성을 갖는 설계가 필요한데 이는 나중에 시스템의 수정보완 등을 고려할 때 중요하다. 본 논문에서는 원자력시설의 공기조화계통 설계에 고려해야 할 내용 및 외국시설에 대하여 검토하였는바, 원자력시설의 공기조화계통 설계에 활용될 수 있겠다.

  • PDF

단일 통풍형과 이중 통풍형 인공습지시스템의 하수처리 효율 비교 (Comparison of Removal Efficiencies in Single and Duplex Ventilation Constructed Wetland Systems for Treating Domestic Sewage)

  • 서동철;임석천;조인성;이병주;이홍재;김상돈;이준배;조주식;허종수
    • 한국환경농학회지
    • /
    • 제28권3호
    • /
    • pp.258-265
    • /
    • 2009
  • 농어촌 등에서 소규모로 발생하는 하수처리를 위한 환경 친화형 자연정화공법인 인공습지 하수처리장 개발을 위하여 수직흐름조(VF)-수평흐름조(HF) 인공습지 시스템을 수직흐름조는 현행 단일 통풍 구조에서 이중 통풍 구조로, 수평흐름조는 깊이를 현행 1.0 m에서 1.3 m로 하여 체적은 같으면서 표면적을 줄여 시공한 다음, 수직흐름조 통풍방법별, 수평흐름조 깊이별 및 하수부하량에 따른 수처리 효율을 조사하였다. 수직흐름조 통풍 방법에 따른 수처리 효율을 조사한 결과 BOD 및 COD는 이중 통풍형 구조가 단일 통풍형 구조에 비해 높은 처리효율을 보였다. 하지만 총 질소와 총 인은 두통풍형 구조 모두 큰 차이 없이 유사한 결과를 보였다. 따라서 수직흐름조의 최적 통풍방법은 이중통풍형 구조이었다. 수평흐름조 깊이에 따른 수처리 효율을 조사한 결과 BOD, COD, 총 질소 및 총 인 함량은 수평흐름조 깊이에 따라 별차이가 없었지만, 수평흐름조 깊이 1.3 m의 경우 인공습지 하수처리장의 시공시 부지면적을 감소시킬 수 있을 것으로 판단되므로 깊이 1.0 m에 비해 경제성과 유지관리면에서 바람직할 것으로 생각된다. 따라서 수평흐름조의 최적 깊이는 1.3 m이었다. 농어촌 지역에서 소규모로 발생하는 하수의 하수부하 변동에 대한 대응성을 조사하기 위하여 하수부하량에 따른 수처리 효율을 조사한 결과 BOD처리율은 하수부하량이 적을수록 약간 높았으며, COD 및 SS는 하수부하량에 따라서 별 차이가 없었고, 동일한 하수부하량에서는 이중 통풍형 공법이 대조구인 단일 통풍형 공법에 비해 높은 처리효율을 보였다. 총 질소 및 총 인 처리효율도 하수부하량이 증가함에 따라 처리효율이 점점 감소되는 경향이었고, 동일한 부하량에서는 이중 통풍형 공법이 단일 통풍형 공법에 비해 처리율이 약간 높았다. 따라서 하수처리장 공법별 및 하수부하량에서의 하수처리효율과 경제성 및 유지 관리비를 고려해볼 때 농어촌 등에서 소규모로 발생하는 하수를 효과적으로 처리하기 위한 인공습지 하수처리장은 수직흐름조 통풍방법이 이중 통풍형 구조이며 수평흐름조의 깊이가 1.3 m인 이중 통풍형 공법이 되어야 할 것으로 판단된다.

유해물질 제거를 위한 국소배기장치 후드의 흡입력 증가에 관한 연구 (A Study on Inhalation Force Improvements of Ventilation Hood For Removed a Pollution Source)

  • 양호동;김영선;오율권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2327-2332
    • /
    • 2007
  • This study investigates on the inhalation force improvements of hood consisted one of the local ventilation systems attached the new device named as gas-guidance-device for removed a pollution source. The numerical method applying finite element method is calculated the velocity and pressure distributions of a moving fluid at the beginning and the inside of a hood with and without the gas-guidance-device in hood. And, the experimental study is measured the wind velocity using the anemometer at the same condition of numerical study. Also, the optimum shape of gas-guidance-device which is suitable for hood shape derived from the numerical and experimental results. The results of this study is supplied the important data to an industrial field for control of a pollution source in the engineering aspect. Moreover, the introduced technique of hood attached the gas-guidance-device is very useful to remove the harmful materials such as dust and waste happened in the manufacturing factory.

  • PDF

일조와 조망, 자연환기성능을 고려한 공동주택 배치계획에 관한 연구 (A Study on the Planning of Multi-Family Residential Buildings considering Daylight, View and Natural Ventilation)

  • 최두성;조균형
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.55-64
    • /
    • 2010
  • The study has conducted a research on the main shape of domestic multi-family residential buildings. The four arrangements were selected after the research and each of them was analyzed for daylight, view and natural ventilation according to the different pitch of buildings. Based on the results from the analysis, the optimum pitch of buildings for each of the arrangements are as follows. With looking at the outcomes from the analysis on changes in residential environment by the pitch of building buildings in the four arrangements, it was figured out that it would be the best if the distance is more than 1.0H for Case_1. For Case_2, it should be more than 0.9H and for Case_3, it has to be 1.0H or more. Last but not least, it seems to be superb if the distance is more than 0.9H for Case_4.

심부 석탄광산의 환기시스템 최적화 연구 (A Study on Optimum Ventilation System in the Deep Coal Mine)

  • 권준욱;김선명;김윤광;장윤호
    • 터널과지하공간
    • /
    • 제25권2호
    • /
    • pp.186-198
    • /
    • 2015
  • 본 연구에서는 적정 소요환기량의 확보를 통한 갱내 환경의 최적화를 위한 기초연구로 갱내 소요환기량을 추정하였다. 채굴의 심부화 및 운행갱도의 증가로 인한 온도상승으로 작업환경이 점차 악화되는 광산에서 작업환경의 개선을 위하여 J광업소를 대상으로 환기평가를 하였으며 갱내의 환기효율을 증가시키기 위하여 갱도의 길이에 따른 온도에 대한 효과를 수치 해석하였다. 연구결과 J광업소의 소요환기량은 $17,831m^3/min$으로 산출되었으며, 실제 총 입기량은 $16,474m^3/min$로 환기량이 $1,357m^3/min$ 부족한 것으로 나타났다. 개발된 프로그램을 이용하여 J 광업소의 두 가지 개발모델에 관하여 온도 예측을 하였으며 온도계산의 기본 인자인 환기량 예측을 위해서 수치해석 프로그램인 VnetPC를 사용하였다. 실험 결과 첫 번째 개발모델인 -425ML을 전체 개발할 경우의 C 생산부 주운반갱도 9X의 온도는 $29.30^{\circ}C$로 예측되었으며 두 번째 모델인, A 생산부를 제외한 일부 지역만 개발할 경우의 온도는 $27.45^{\circ}C$로 예측되었다.

Determination of Optimum Threshold for Accuracy of People-counting System Based on Motion Detection

  • Ryu, Hanseul;Song, Junho;Lee, Boram;Lee, Kiyoung
    • 한국환경보건학회지
    • /
    • 제41권5호
    • /
    • pp.299-304
    • /
    • 2015
  • Objectives: A people-counting system measures real-time occupancy through motion detection. Accurate people-counting can be used to calculate suitable ventilation demands. This study determined the optimum motion threshold for a people-counting system. Methods: In a closed room with two occupants moving constantly, different thresholds were tested for the accuracy of a people-counting system. The experiments were conducted at 150, 300, 450 and 600 lux. These levels of brightness included the illumination levels of most public indoor areas. The experiments were repeated with three types of clothing coloration. Results: Overall, a threshold of 16 provided the lowest mean error percentage for the people-counting system. Brightness and clothing color did not have a significant impact on the results. Conclusion: A people-counting system could be used with threshold of 16 for most indoor environments.