• Title/Summary/Keyword: optimum operation

Search Result 1,185, Processing Time 0.031 seconds

A Study on the Performance Improvement for The Coal Filing Power Station (엑서지분석을 통한 대용량 석탄화력 발전소의 성능개선 연구)

  • 서주오
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.165-176
    • /
    • 2003
  • In this study, the exergy analysis is conducted on the well known performance of already developed system and then compared with the efficiency of each equipment to propose optimum operation of the system. The system used in this study is 500 MW coal firing power plant. The efficiency of the boiler is 67% and the condenser is 99% by exergy analysis. The exergy consumption of the boiler was 32.95% at 100% load. The exergy consumption of the high pressure turbine and the low pressure turbine is 8.31% and 8.12%, respectively. Together with the concrete study on the object of performance revision of the low efficient development system proved in this study, if detailed exergy analysis on the operation condition of the equipments of the development system presently being operated is continued, then it is expected to help minimize the exergy consumption of relatively low efficient parts that are worn-out or miss-installed.

Performance Characteristic of Live Fishing Tank in Cooling Apparatus inshore Fishing Boat (연근해 어선용 활어조 냉각장치의 성능특성)

  • 한인근;이호생;김재돌;김흥윤;윤정민
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.52-56
    • /
    • 2001
  • A fundamental study on the cooling apparatus inshore fishing boat and its operation characteristics in sea water cooling system were performed experimentally. The circumstance is giving the blow against fisherman with incoming-decreasing and the difficulty of crew's supply and demand and management. In addition, the depression of the external situation such as the plan of EEZ(Exclusive Economic Zone) proclaim is forcing them into improving their fishing condition. By this international and domestic surrounding, the development of a cooling apparatus inshore fishing boat is demanded sincerely. We investigated load characteristics as the pilot plant operation characteristics estimation which is based on the development of cooling system and optimum cooling apparatus inshore fishing boat. These results provide useful informations which are applicable to an actual design and show the possibility of application to other fields.

  • PDF

Investigation of Natural Air Drying of Rough Rice Based on The Weather Data in Taegu Area (대구지방의 기상자료를 기초로한 벼의 상온통풍건조에 관한 조사연구)

  • 김재열;서승덕;금동혁;서석건
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.15-23
    • /
    • 1980
  • Natural-air drying systems have been extensively used for cereal grains, and many researches on the systems have been conducted in foreign countries. However, little research on drying rough rice with natural air has been done. Especially . little research on natural air drying of rough rice based on weather data has been done in Korean. The objective of this study was to present fundamental data for estimating optimum requirements and basic information available for natural air drying of rough rice based on the weather data . The weather data analyzed in this study were the 10-year (1969 to 1978) record of air temperatures, wet-bulb temperatures and relative humidities, which were three-hourly observations in Taegu area. The results of this study are summarized as follows ; 1 From the results of weather data analysis the average air temperature was about $14.8^\circ$and the average relative humidty 67.5% . Average equilibrium moisture content appeared to be 13.8 percent on wet basis, which showed great potential for natural air drying in Taegue area in October. 2. Possible fan operation time based on the equilibrium moisture content of 15% on wet basis was about 14 hours a day during October in Taegu area. Probabilities of possible drying days based on minimum time available for drying in a day were analyzed. 3. Minimum air flow requirements based on the worst year were determined for different fan operation methods and initial moisture contents.

  • PDF

Development of Coating Robot Automation System Based on OLP for Radiators in PPS (페키지형 발전시스템용 라디에이터의 OLP 기반 코팅로봇 자동화시스템 개발)

  • Kim, Seon-Jin;Lee, Jong-Hwan;Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.585-591
    • /
    • 2013
  • A robot automation system for coating uniformly a big radiator used in PPS(Packaged Power Station), which consists of 6-axis robot with spray gun, travelling vehicle, supply device of coating paint and thinner with pressured air, HMI controller and robot path OLP(Off-Line Programming), was developed. Experimental results on an optimum operation condition show that a coating thickness is $43{\mu}m$, which is satisfied to a design reference of $25-100{\mu}m$. A productivity of the developed coating robot automation system based on OLP is about 12.6 times of that of manual operation.

THE EFFECT OF COOLSTORE DESIGN AND OPERATION ON AIR RELATIVE HUMIDITY

  • Amos, N.D.;Cleland, D.J.;Cleland, A.C.;Banks, N.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.433-442
    • /
    • 1993
  • Coolstore air relative humidity (RH) is an important factor affecting the quality of horticultural products, particularly via product moisture loss. RH also has an important effect on the performance of the refrigeration evaporators and can affect the strength of paper-based packaging materials. In a large New Zealand apple coolstore, RH increased from about 75% early in season to 90% at the end, as activities in the coolstore and external conditions changed. A steady-state analysis of sensible and latent heat entry and heat removal during four typical operational periods over the season was carried out. Predicted RH was in good agreement with measured dat. For the coolstore studied, evaporator surface area and the occurrence of pre-cooling within the coolstore were the design and operational factors having greatest effect on RH. Door protection and management, and floor insulation were the next more significant factors. The method of analysis has more general application and ould be used in a variety of situations so that design for optimum RH can be performed systematically.

  • PDF

Performance of a 2 Room Multi-Heat Pump with a Constant Speed Compressor

  • Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.184-191
    • /
    • 2004
  • In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.

Soft Error Rate for High Density DRAM Cell (고집적 DRAM 셀에 대한 소프트 에러율)

  • Lee, Gyeong-Ho;Sin, Hyeong-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.87-94
    • /
    • 2001
  • A soft error rate for DRAM was predicted in connection with the leakage current in cell capacitor. The charge in cell capacitor was decreased during the DRAM operation, and soft error retes due to the leakage current were calculated in various operation mode of DRAM. It was found that the soft error rate of the /bit mode was dominant with small leakage current, but as increasing the leakage current memory mode shown the dominant effect on soft error rate. Using the 256M grade DRAM structure it was predicted that the soft error rate was influenced by the change of the cell capacitance, bit line capacitance, and the input voltage sensitivity of sense amplifier, and these results can be used to the design of the optimum cells in the next generation DRAM development.

  • PDF

Nitrogen Removal in Livestock Wastewater Using Sequencing Batch Reactor (SBR을 이용한 축산폐수의 질소 제거)

  • Shin, Hang-Sik;Kim, Ku-Yong;Lee, Sang-Hyung;Lim, Jae-Lim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.61-67
    • /
    • 2003
  • A new precess which consists of pre-dewatering device, post composting for solid phase and post sequencing batch reactor(SBR) for liquid phase was designed. Nitrogen in supernatants of dewatering device was removed by sequencing batch reactor. Experiments were carried out to investigate the SBR operation modes such as fill ratio, SRT, and operation cycle. The optimum fill ratio, SRT and aeration/non-aeration time were 1/12, 15days, and 2hr aeration / 1hr non aeraion, respectively. Methanol as an external carbon source increased denitrification when step feeding method was applied, not single feeding method.

  • PDF

A study on the determination for stochastic reservoir capacity (추계학적(推計學的) 저수용량(貯水容量) 결정(決定)에 관(關)한 연구(硏究))

  • Choi, Han-Kuy
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.69-74
    • /
    • 1983
  • For the determination of a reservoir capacity Rippl's mass-curve method has long been used with the past river flow data assuming the same flow records will be repeated in the future. This study aims to find out a better method for determining the reservoir capacity by employing the analytical theory based on the stochastic process. For the present study the synthetic generation methods of Thomas-Fiering type was used to synthetically generate 50 years of monthly river inflows to three single-purpose reservoirs and three multi-purpose reservoirs. The generated sequences of monthly flows were analyzed based on the range concept. With the optimum operation rule of the reservoirs as the one which maximizes the water-use downstream the waterrelease from the reservoir was determined and with due consideration to the mean inflows and the range of monthly flows the required reservoirs capacity was stochastically determined. It was possible to repersent the so-determined reservoir capacity in terms of the mean monthly inflows and the number of subseries in the determination of ranges. It is suggested that the result obtained in this study would be applied to approximately estimate, in the stage of preliminary design, the required capacity of a reservoir in question with the limited information such as the mean monthly inflow and the period of reservoir operation.

  • PDF

An Experimental Study on the Performance Characteristics of a Heat Pump System in the Heating Operation Mode with the Hot Gas Bypass (열펌프의 난방운전시 핫가스 바이패스에 따른 성능 특성에 관한 실험적 연구)

  • Ahn, Jae-Hwan;Joo, Young-Ju;Cho, Il-Yong;Kang, Hoon;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.539-543
    • /
    • 2009
  • When the suction pressure of compressor decreases under its limit, the compression ratio is increased causing the malfunctions of compressor. As the method to decrease the compression ratio, hot gas bypass system is usually adopted in heat pump system. In the hot gas bypass system, the discharged gas from the compressor is bypassed into the compressor suction, which causes the increase of suction pressure and the decrease of compression ratio. In this study, the characteristics and performances of the hot gas bypass system in heat pump was investigated experimentally with a variation of the bypass flow rate ratio. With the increase of the bypass rate ratio, the compressor suction pressure was increased, even though the total capacity and COP was decreased. From the analysis of the experimental results, the optimum pressure control algorithm was suggested in this study.

  • PDF