• Title/Summary/Keyword: optimum maintenance

Search Result 377, Processing Time 0.026 seconds

Soybean Wastewater Treatment by Activated Sludge Process (고농도 대두가공폐수의 처리를 위한 개선 활성슬러지법)

  • Cho, Kwon-Ik;Lee, Jeoung-Su;Lee, Tae-Kyoo;Kim, Jong-Hwa
    • Applied Biological Chemistry
    • /
    • v.45 no.1
    • /
    • pp.25-29
    • /
    • 2002
  • The kernel of wastewater treatment by activated sludge is elimination of organic substances and maintenance of well-flocculated sludge sedimentation. By the conventional activated sludge treatment, the optimum F/M ratio of soybean wastewater treatment was 0.24 (kg-BOD/kg-MLVSS day) and sludge bulking was generated at 0.48 (kg-BOD/kg-MLVSS day). To improve the treatment capacity and operation quality in higher loading of soybean wastewater, influent pH was constantly controlled by 9.0 using NaOH as a coagulant agent. In this process, higher loading up to 2.88 (kg-BOD/kg-MLVSS day) was possible and SVI was maintained under 150 without bulking. This was equivalent to 7.2 times higher than maximum permissible load of the conventional activated sludge process.

Feasibility Study of Natural Systems for Sewage Treatment and Agricultural Reuse (자연정화방법에 의한 오수처리와 농업적 재이용 타당성 검토)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.194-206
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent to agricultural reuse of reclaimed water. The constructed wetland and pond system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the wetland system. The effluent of the wetland was used as an influent to pond systems. The influent concentrations of total coliform(TC), fecal coliform (FC), and E. coli were about $10^5$MPN/100 ml, and they were reduced to less than 10,000 MPN/100 ml on average after wetland treatments, showing over 95 % removal. And they were further reduced to less than 1,000 MPN/100 ml in average, showing over 85∼93 % removal after pond treatment. Turbidity and SS were improved effectively on average and their pond effluent concentration was about 4.5 NTU and 9.8 mg/L in average, respectively Average $BOD^5$ concentrations were also reduced substantially to 9.3 mg/L with about 83 % removal rate after wetland and pond treatment systems. Nutrients removal was relatively low and removal rate for T-N and T-P was less than 43 and 44%, respectively after wetland and pond treatment. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper describes a preliminary result Iron pilot study and further investigations are recommended on the optimum design parameters before full scale application.

Determination of the Resetting Time to the Process Mean Shift by the Loss Function (손실함수를 적용한 공정평균 이동에 대한 조정시기 결정)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.1
    • /
    • pp.165-172
    • /
    • 2017
  • Machines are physically or chemically degenerated by continuous usage. One of the results of this degeneration is the process mean shift. Under the process mean shift, production cost, failure cost and quality loss function cost are increasing continuously. Therefore a periodic preventive resetting the process is necessary. We suppose that the wear level is observable. In this case, process mean shift problem has similar characteristics to the maintenance policy model. In the previous studies, process mean shift problem has been studied in several fields such as 'Tool wear limit', 'Canning Process' and 'Quality Loss Function' separately or partially integrated form. This paper proposes an integrated cost model which involves production cost by the material, failure cost by the nonconforming items, quality loss function cost by the deviation between the quality characteristics from the target value and resetting the process cost. We expand this process mean shift problem a little more by dealing the process variance as a function, not a constant value. We suggested a multiplier function model to the process variance according to the analysis result with practical data. We adopted two-side specification to our model. The initial process mean is generally set somewhat above the lower specification. The objective function is total integrated costs per unit wear and independent variables are wear limit and initial setting process mean. The optimum is derived from numerical analysis because the integral form of the objective function is not possible. A numerical example is presented.

A Study on Objective Functions for the Multi-purpose Dam Operation Plan in Korea (국내 다목적댐 운영계획에 적합한 목적함수에 관한 연구)

  • Eum, Hyung-Il;Kim, Young-Oh;Yun, Ji-Hyun;Ko, Ick-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.9 s.158
    • /
    • pp.737-746
    • /
    • 2005
  • Optimization is a process that searches an optimal solution to obtain maximum or minimum value of an objective function. Many researchers have focused on effective search algorithms for the optimum but few researches were interested in establishing the objective function. This study compares two approaches for the objective function: one allows a tradeoff among the objectives and the other does not allow a tradeoff by assigning weights for the absolute priority between the objectives. An optimization model using sampling stochastic dynamic programming was applied to these two objective functions and the resulting optimal policies were compared. As a result, the objective function with no tradeoff provides a decision making process that matches practical reservoir operations than that with a tradeoff allowed. Therefore, it is more reasonable to establish the objective function with no a tradeoff among the objectives for multi-purpose dam operation plan in Korea.

Effects of supplementation of hairy vetch on the quality of whole crop barley silage (헤어리베치의 첨가가 맥류 사일리지의 품질에 미치는 영향)

  • Jang, Won-Sup;Yang, Byung-Mo;Heo, Jung-Min;Lee, Hyung-Suk;Lee, Soo-Kee
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.4
    • /
    • pp.383-388
    • /
    • 2015
  • This study was conducted to investigate the effects of hairy vetch supplementation on quality of winter crop silage. There were 4 treatments (addition levels of hairy vetch ; 0, 5, 15, and 30%) with 3 replicates. Experimental silages stored for 40 days at room temperature ($20-25^{\circ}C$). THe silage crude protein level was improved (P<0.05) while hairy vetch supplementation increased. However, no difference was found (P>0.05) in crude fat, NDF and ADF of the silage while hairy vetch supplementation increased. The silage pH was increased (P<0.05) but lactic acid level was decreased (P<0.05) while hairy vetch supplementation increased. Nonetheless, acetic and butyric acids concentrations were increased (P<0.05) while hairy vetch supplementation increased. Sucrose, glucose and fructose levels were increased (P<0.05) while hairy vetch supplementation increased. Although negative effects were detected in whole crop barley silage while hairy vetch supplementation increased, optimum level of hairy vetch supplementation could be overwhelmed its negative effects on whole crop barley silage. Thus, the results of present study suggested that 15% hairy vetch supplementation of whole crop barley silage would be beneficial its quality maintenance compared to whole crop barley silage per se.

Preparation and Characterization of PE Liposomes Containing Antibody (항체를 포함하는 Phosphatidylethanolamine 리포좀의 제조와 그 특성)

  • 박성호;신현재양지원최태부
    • KSBB Journal
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 1995
  • A target-sensitive liposome was prepared by using a dioleoyl-phosphatidylethanolamine(DOPE) and a palmitic acid coupled antibody(p-IgG). For the preparation of stable PE-liposomes, the key factors such as antibody modification method with palmitic acrid, molar ratio of p-IgG to lipid and the amount of various additives, were examined. The optimum molar ratio of p-IgG to lipid was found to be $2.5{\times}10^{-4}$ and the final concentration of deoxycholate for the stable liposome formation was about 0.09%. Two kinds of target-sensitive liposomes, containing polyclonal anti-SRBC(Sheep Red Blood Cell)-antibody and monoclonal anti-${\beta}$-HCG(Human Chorionic Gonadotropin)-antibody, were successfully prepared. The destabilization of liposomes was examined by measuring the release of calcein entrapped in the liposome vesicles. Calcein was released only when the liposomes were contacted with the specific target cells. The calcein release with non-specific target cells was negligible. From this result, it is clear that p-IgG is indispensible for the maintenance of stable PE-liposome and the calcein release is mainly due to the specific interactions between the liposomes containing antibody and the target cells containing antigen.

  • PDF

Improvement Direction of Facility Management System(FMS) through Related Systems Analysis (유관 시스템 분석을 통한 시설물정보관리종합시스템 개선방향)

  • Jung, In-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6751-6758
    • /
    • 2015
  • The Special Act on Safety Control for Infrastructure was enacted in 1995 to contribute to ensuring the public safety and welfare improvement of Korean people. In addition, the FMS has been developed and operated to manage facilities effectively. However, several problems of the FMS have also occurred. Thus, this study aimed to analyze the FMS and related systems scrutinizingly to suggest improvement directions such as (1) extension of the FMS into the national facility information management system including small-size facilities other than Types 1 and 2 facilities, (2) development and promote standardized inspection and diagnosis systems as per facility type, (3) development of the database utilization system including decision making support function for management body, and (4) providing the FMS performance improvements and stable operating environment utilizing latest information technologies. If the improvement directions suggested in this study are adopted, they can improve services for Korean people by providing facility safety and maintenance work parties with optimum information services.

Improvement of Single Anaerobic Reactor for Effective Nitrogen Removal (효율적 질소제거를 위한 단일 혐기성반응조의 개선)

  • 한동준;류재근;임연택;임재명
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.9-17
    • /
    • 1997
  • This research aims to remove nitrogen in the piggery wastewater by combined process with upflow anaerobic sludge blanket (UASB) and biofilm process. For the effective denitrification. anaerobic and anoxic reactors were connected to a reactor. The effluent of aerobix reactor was recycled equally with influent in the upper filter of anaerobic reactor for denitrification and outlet of UBF reactor was connected to the settling tank with $1.5{\;}{\ell}$ capacity and the settling sludge was repeatedly recycled to UASB zone. The organic loading rate of total reactor was operated from 0.4 to $3.1kgCOD/m^{3}/d$ and it was observed that the removal rate of TCOD was 80 to 95 percentage. Ammonia nitrogen was removed over 90 percentage in the less volumetric loading rate than $0.1{\;}kgN/m^{3}/d$. But because of non-limitation of organic materials, it was reduced to 70 percentage in the more volumetric loading rate than $0.6{\;}kgN/m^{3}/d$. But denitrification rate was observed 100 percentage in the all of loading rate. This is caused by the maintenance of optimum temperature, sufficient carbon source, and competition of electron acceptors. The results of COD mass balance at the $1.21{\;}kgCOD/m^{3}/d$ was observed with the 71.7% percentage of influent COD. It was revealed that the most part of organic materials was removed in the aerobic and the anaerobic reactor because 38.4 percentage was conversed into $CH_{4}$ gas and 11 percentage was removed in the aerobic reactor with cell synthesis and metabolism. Besides, 5.7% organics was used to denitrification reaction and 3.7% organics related to sulfate reduction.

  • PDF

Application of Electrochemical Method for Decolorization of Biologically Treated Animal Wastewater Effluent (생물학적 축산폐수 처리수 색도제거를 위한 전기화학적 방법의 적용)

  • 윤성준;신종서;라창식
    • Journal of Animal Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.315-324
    • /
    • 2006
  • This research was conducted to clarify the characteristics of electrochemical decolorization of effluent discharged from a biological animal wastewater treatment process and to finally establish parameters or mode for optimum operation of electrolysis system. Average color unit of wastewater was about 1,200 and DSA(Dimensionally Stable Anode) was used as electrode. Experiments were performed with two different operation conditions or modes, fixed voltage-free current(Run A) and free voltage-fixed current(Run B). Color removal rate was proportional to the electrode area and electrical conductivity, and an equation subject to them at a condition of fixed voltage was derived as follows; Ct=C0ekt, k=[{0.0121×a(dm2)× c(mS/cm)}+0.0288], [where, C0: initial color, Ct: color unit after treatment for t, k: reaction coefficient, t: time(min.), a: electrode area, c: conductivity]. From the study on the effects of current density on color removal, it was revealed that the removal efficiency of color was function of the current density, showing direct proportion. However, when considered energy consumption rate, maintenance of low current density was an economical way. Based on the obtained results, it was concluded that supplementation of electrolyte is not necessary for the removal of color from the effluent of secondary treatment process and operation with the mode of free voltage-fixed current, rather than operation with fixed voltage-free current mode, would be an efficient way to increase the removal performance and capacity per consumed energy.

Factors Associated with Bone Mineral Density in Korean Postmenopausal Women Aged 50 Years and Above: Using 2008-2010 Korean National Health and Nutrition Examination Survey (50세 이상 폐경 후 여성의 골밀도와 연관성을 보이는 요인: 2008-2010년 국민건강영양조사 자료를 이용하여)

  • Mun, Son-Ok;Kim, Jihye;Yang, Yoon Jung
    • Korean Journal of Community Nutrition
    • /
    • v.18 no.2
    • /
    • pp.177-186
    • /
    • 2013
  • The purpose of this study was to investigate factors associated with Bone Mineral Density (BMD) in Korean postmenopausal women. The data from 2008-2010 Korean National Health and Nutrition Examination Survey (KNHANES) were used for data analysis. Subjects were 2,701 postmenopausal women aged ${\geq}50$ years. BMDs at whole body, total femur, femoral neck, and lumbar spine were measured by Dual-energy X-ray absorptiometry (DXA). Dietary data from 24-hour dietary recall and a food frequency questionnaire containing 63 food items were used. The proportions of osteopenia at total femur, femoral neck, and lumbar spine were 37.4%, 54.5%, and 45.4%, respectively. The proportions of osteoporosis at total femur, femoral neck, and lumbar spine were 6.2%, 25.6%, and 34.3%, respectively. Age, anthropometric index including height, weight, and Body Mass Index (BMI), parathyroid hormone, and physical activity were related to BMD, but the relationships were site specific. Total femur BMD was explained by age, weight, parathyroid hormone and intakes of carbohydrate and fruits. Femoral neck BMD was related to age, weight, parathyroid hormone and intakes of riboflavin and fruits. Lumbar spine BMD was associated with age, weight, milk and dairy products, calcium intake, and exercise. These results indicated that adequate intakes of milk and dairy products, fruits, carbohydrate, calcium, riboflavin and exercise as well as weight maintenance might play an important role in maintaining optimum bone health in Korean postmenopausal women.