• Title/Summary/Keyword: optimum location

Search Result 431, Processing Time 0.027 seconds

A Study on the Estimation of Ecological Footprint in Gyeongsangbuk-do for Comparison of Environmental Capacity of Each Local Government (자치단체별 환경용량 비교를 위한 경상북도지역 생태발자국 추정연구)

  • Kang, Kee-Rae;Kim, Hee-Chae;Kim, Dong-Pil;Oh, Hyun-Kyung;Cho, Kwang-Jin;Shin, Young-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.6
    • /
    • pp.769-778
    • /
    • 2014
  • The rapid urbanization and increase in population due to industrialization have led to the extension of cities and the reduction in naturality as a necessity. Now, it is the biggest threat to virtuous circle of ecosystem. With the expansion of common recognition that this ecological crisis would be accompanied by the crisis of mankind, many countries all around the world are conducting researches to indicate the optimum consumption level of individual as an index in addition to cross-national environmental indicators such as ESI, EPI and SDI, by measuring environmental consumption of state, local government or individual, and comparing each region. Based on this background, this research was carried out to estimate the environmental capacity of 23 local government in Gyeongsangbuk-do. The result of EF estimation showed that EF value necessary for life per head in Gyeongsangbuk-do was 0.9534, and it showed an ecological deficit of 25.3 percent when analyzing it in consideration of the ecological capacity. Also, among the local governments in Gyeongsangbuk-do, Youngduk-gun displayed the highest EF, and Ulleung-gun displayed the lowest EF. But when analyzing the ecological deficit in consideration of the ecological capacity of each region, Gumi-city showed the greatest ecological deficit, and Youngyang-gun showed the biggest ecological capacity. The environmental capacity estimated in this study is to digitize the ecological capacity and ecological deficit of each local government in Gyeongsangbuk-do. The estimated optimum environmental capacity of each local government suggests the scale of environmental preservation and proper development and furthermore, could be used as fundamental data for persuading members of each local government when selecting a location of development facility or preservation area.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Relationships between Fishing Condition and Sea Surface Temperature for Skipjack(Euthynnus pelamis) Caught by Small Fishing Boats (소형어선에 의한 가다랑어 (Euthynnus pelamis)의 어황과 수온)

  • Jeong, Dong-Gun;Rho, Hong-Kil
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.10 no.1
    • /
    • pp.15-30
    • /
    • 1998
  • The variation of the catches of Skipjack(Euthynnus pelamis) and the relationships between the SST and the fishing ground is examined using the catches data of skipjack obtained by Iwawada Fisheries Cooperative of Chiba Prefecture in Japan from 1982 to 1988. The annual mean catch for Skipjack was 151,375.1kg. the annual fluctuation of catch was that the catch in 1984 was increasing, but it was decreased less than 50% in 1985, and was repeated after being a little recovered in 1986, and it was recovered with the level of 1984 in 1988. The fluctuation of catch for Skipjack in every fishing term is that daily mean catch of the primary fishing term (January, February and March) is 894.6kg, but the middle fishing term(April and May) more than four times of the primary fishing term is 3,666.0kg, the last fishing term(June and July) was decreasing at 767.9kg and the fishing ground gradually becomes extinct. The annual mean SST in fishing ground was an extent of from $19.0^{\circ}C$ to $20.2^{\circ}C$, the mean SST of every year except 1983 was from $19.0^{\circ}C$ to $19.9^{\circ}C$. It is said that the optimum SST of Skipjack in Sotobo sea area is the degree of $19.0^{\circ}C$. Therfore, the thing which will guess the time and the location appeared the optimum SST is the very important factor to operate efficiently. About the extent of SST in fishing ground, it was from $17.0^{\circ}C$ to $19.0^{\circ}C$ on March, from $17.5^{\circ}C$ to $20.5^{\circ}C$ on April and from $17.5^{\circ}C$ to $23.5^{\circ}C$ on May, which the extent of SST was gradually larger and larger, on June from $21.0^{\circ}C$ to $23.5^{\circ}C$, fishing ground was formed only the degree of SST more than $21.0^{\circ}C$.

  • PDF

Recognition Level of Organization, Motivation and Job Satisfaction Factors of the Staff of Health Centers (보건소직원의 조직에 대한 인식과 동기부여요인 및 직무만족요인)

  • 남철현;위광복
    • Health Policy and Management
    • /
    • v.10 no.3
    • /
    • pp.19-49
    • /
    • 2000
  • This study was conducted to help staff members of health centers manage personnel by examining the staff members' recognition level of organization structure of health centers, their motivation, their job satisfaction level and its related factors. Data were collected from 471 staff members of 14 health centers from March 3, 1999 to April 30, 1999. The results of this study are summarized as follows. In recognition levels of organization structure of health centers, the recognition level of necessity of discretion right was highest(3.55 points on the base of 5 points), while the recognition level of the location of decision making right was lowest(2.77 points). The general recognition of organization structure of health centers was 3.06 points, the suitability of division of duties was 3.05 points, and the optimum of manpower and budget was 2.93 points. The staff members' general recognition level of the organization structure appeared significantly higher in case of the groups of small and medium sized cities, above fifties, below high school graduate, above the sixth grade, public service experience of above 20 years, service period of below 2 years at present post, and average monthly salary of one million, eight hundred and ten thousand won. In the recognition level of the location of decision making right, the groups of big cities, male, the married, above the sixth grade, health and administration posts, average monthly salary of one million, three hundred and ten thousand won to one million, and eight hundred thousand won were significantly higher than the other groups. The recognition level of necessity of discretion right was higher in case of the groups of the twenties, the unmarried, above college graduate, nursing post, public service experience of below 5 years, service period of below 2 years at present post, and average monthly salary of below eight hundred thousand won. In the recognition level of suitability of division of duties, the groups of small and medium sized cities, the married, medical technicians, public service experience of above 20 years, and service period of below 4 years at present post were significantly higher than the other groups. In the staff members' recognition levels of organization management, the recognition level of opinion response when making decision was highest(2.92 points). The recognition level of rationality of the target amount establishment method was 2.88 points and the recognition level of personnel management was 2.63 points. The recognition level of personnel management was significantly higher in case of the groups of small and medium sized cities, the forties, above the sixth grade, medical technicians, public service experience of above 20 years, service period of below 2 years at present post, and average monthly salary of above one million, eight hundred and ten thousand won. In the recognition level of opinion response when making decision, the groups of small and medium sized cities, female, the eighth grade, health and administration posts, and service period of below 2 years at present post were higher than the other groups. The recognition level of rationality of the target amount establishment method was significantly higher in case of the groups of above fifties, below high school graduate, above the sixth grade, medical service post, and public service experience of 15 to 20 years. The factors significantly influencing sanitation were sex, education level, the period of public service experience, general recognition of organization structure, recognition of necessity of discretion right, recognition of suitability of division of duties, and recognition of opinion response when making decision. The factors which significantly influenced motivation were marital status, grade, recognition of the location of decision making right, recognition of necessity of discretion right, recognition of division of duties, recognition of opinion response when making decision, and sanitation. Sex, education level, recognition of suitability of division of duties, recognition of the target amount establishment method, and motivation influenced job satisfaction significantly. The factors significantly influencing organization culture were age, the period of public service experience, service period at present post, recognition of optimum of manpower and budget, recognition of suitability of division of duties, recognition of opinion response when making decision, and recognition of rationality of the target amount establishment method. In the coming days, the staff members' job satisfaction level must be increased through motivation and efficient conduct of duty must be accomplished through rational organization structure and management. Moreover, change of the staff members' consciousness and administrative system which are suitable for local autonomy system have to be established with increase of local residents' consciousness level and education level. Forming organization culture by reformative idea which fits the new era, public health service by the Community Health Act and health education service by the Health Promotion Act must be carried out efficiently. In doing so, financial support of central government and active efforts and concerns of local governments have to be devoted in order to get public health service in which peculiarity of the community is considered to be pursued well.

  • PDF

The Study of Operating Conditions by Establishing Density Currents Generator for Improving of Water Quality on Lake Water - With Focus on DO and Water Temperature - (호소수의 수질개선을 위한 DCG 설치시 운전조건에 관한 연구 - DO와 수온을 중심으로 -)

  • Lee, Young-Shin;Han, Kyung-Hee;Kim, Young-Kyu;An, Hyung-Chul;Shin, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.286-294
    • /
    • 2014
  • The purpose of this study is to investigate the effects of applying density current generator (hereafter referred to as DCG to large lakes on the operating conditions of DCG, de-stratification, water quality improvement and inhibition of algae occurrence. As a result of a survey conducted to derive the optimum operating parameters of DCG in a condition to minimize eco-toxicity, the following conclusions were obtained. During the survey period, a marked stratification appeared in September to October 2011 and May 2012. At this time, the average depth of water to form thermocline was found to be $5{\pm}2$ m, so the location of discharge port for the operation of DCG was determined to be about 5 m below from the surface. To minimize the adverse effects of benthos and obtain the effect of water mixture at the time of water circulation, the mixing ratio of surface water and deep water was designed to be 3:1 by means of ecotoxicological assessment on the DCG operating characteristics. To select the appropriate operating hours for DCG, DCG was operated by 12 hr, 24 hr, 36 hr and 48 hr. As its result, the formation of thermocline did not occur during the operation of 36 hr. Also, It was effected that start reoperating from 3rd day after stop 2days under the condition of operated during 36 hr with calculated power consumption. Under the above conditions, the results of DO and water temperature analysis during the operation of DCG showed that the stratification, which was distinct previously, appeared to be weak, and relatively lower levels than those before operation were found as a result of water quality analysis on COD and chlorophyll-a, which leads to the conclusion that the water body is maintained at a stable condition due to the circulation of water by the occurrence of density current resulting from the operation of DCG.

Impact of Sulfur Dioxide Impurity on Process Design of $CO_2$ Offshore Geological Storage: Evaluation of Physical Property Models and Optimization of Binary Parameter (이산화황 불순물이 이산화탄소 해양 지중저장 공정설계에 미치는 영향 평가: 상태량 모델의 비교 분석 및 이성분 매개변수 최적화)

  • Huh, Cheol;Kang, Seong-Gil;Cho, Mang-Ik
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.187-197
    • /
    • 2010
  • Carbon dioxide Capture and Storage(CCS) is regarded as one of the most promising options to response climate change. CCS is a three-stage process consisting of the capture of carbon dioxide($CO_2$), the transport of $CO_2$ to a storage location, and the long term isolation of $CO_2$ from the atmosphere for the purpose of carbon emission mitigation. Up to now, process design for this $CO_2$ marine geological storage has been carried out mainly on pure $CO_2$. Unfortunately the $CO_2$ mixture captured from the power plants and steel making plants contains many impurities such as $N_2$, $O_2$, Ar, $H_2O$, $SO_2$, $H_2S$. A small amount of impurities can change the thermodynamic properties and then significantly affect the compression, purification, transport and injection processes. In order to design a reliable $CO_2$ marine geological storage system, it is necessary to analyze the impact of these impurities on the whole CCS process at initial design stage. The purpose of the present paper is to compare and analyse the relevant physical property models including BWRS, PR, PRBM, RKS and SRK equations of state, and NRTL-RK model which are crucial numerical process simulation tools. To evaluate the predictive accuracy of the equation of the state for $CO_2-SO_2$ mixture, we compared numerical calculation results with reference experimental data. In addition, optimum binary parameter to consider the interaction of $CO_2$ and $SO_2$ molecules was suggested based on the mean absolute percent error. In conclusion, we suggest the most reliable physical property model with optimized binary parameter in designing the $CO_2-SO_2$ mixture marine geological storage process.

Improvement of Energy Efficiency of Plants Factory by Arranging Air Circulation Fan and Air Flow Control Based on CFD (CFD 기반의 순환 팬 배치 및 유속조절에 의한 식물공장의 에너지 효율 향상)

  • Moon, Seung-Mi;Kwon, Sook-Youn;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2015
  • As information technology fusion is accelerated, the researches to improve the quality and productivity of crops inside a plant factory actively progress. Advanced growth environment management technology that can provide thermal environment and air flow suited to the growth of crops and considering the characteristics inside a facility is necessary to maximize productivity inside a plant factory. Currently running plant factories are designed to rely on experience or personal judgment; hence, design and operation technology specific to plant factories are not established, inherently producing problems such as uneven crop production due to the deviation of temperature and air flow and additional increases in energy consumption after prolonged cultivation. The optimization process has to be set up in advance for the arrangement of air flow devices and operation technology using computational fluid dynamics (CFD) during the design stage of a facility for plant factories to resolve the problems. In this study, the optimum arrangement and air flow of air circulation fans were investigated to save energy while minimizing temperature deviation at each point inside a plant factory using CFD. The condition for simulation was categorized into a total of 12 types according to installation location, quantity, and air flow changes in air circulation fans. Also, the variables of boundary conditions for simulation were set in the same level. The analysis results for each case showed that an average temperature of 296.33K matching with a set temperature and average air flow velocity of 0.51m/s suiting plant growth were well-maintained under Case 4 condition wherein two sets of air circulation fans were installed at the upper part of plant cultivation beds. Further, control of air circulation fan set under Case D yielded the most excellent results from Case D-3 conditions wherein air velocity at the outlet was adjusted to 2.9m/s.

Design and Implementation of Quality Broker Architecture to Web Service Selection based on Autonomic Feedback (자율적 피드백 기반 웹 서비스 선정을 위한 품질 브로커 아키텍처의 설계 및 구현)

  • Seo, Young-Jun;Song, Young-Jae
    • The KIPS Transactions:PartD
    • /
    • v.15D no.2
    • /
    • pp.223-234
    • /
    • 2008
  • Recently the web service area provides the efficient integrated environment of the internal and external of corporation and enterprise that wants the introduction of it is increasing. Also the web service develops and the new business model appears, the domestic enterprise environment and e-business environment are changing caused by web service. The web service which provides the similar function increases, most the method which searches the suitable service in demand of the user is more considered seriously. When it needs to choose one among the similar web services, service consumer generally needs quality information of web service. The problem, however, is that the advertised QoS information of a web service is not always trustworthy. A service provider may publish inaccurate QoS information to attract more customers, or the published QoS information may be out of date. Allowing current customers to rate the QoS they receive from a web service, and making these ratings public, can provide new customers with valuable information on how to rank services. This paper suggests the agent-based quality broker architecture which helps to find a service providing the optimum quality that the consumer needs in a position of service consumer. It is able to solve problem which modify quality requirements of the consumer from providing the architecture it selects a web service to consumer dynamically. Namely, the consumer is able to search the service which provides the optimal quality criteria through UDDI browser which is connected in quality broker server. To quality criteria value decision of each service the user intervention is excluded the maximum. In the existing selection architecture, the objective evaluation was difficult in subjective class of service selecting of the consumer. But the proposal architecture is able to secure an objectivity with the quality criteria value decision where the agent monitors binding information in consumer location. Namely, it solves QoS information of service which provider does not provide with QoS information sharing which is caused by with feedback of consumer side agents.

Determination of Appropriate Location for Baby Leaf Vegetable in Multi Bench System of Rice Seedling Nursery Facility During High Temperature Periods (다단식 벼육묘시설을 활용한 고온기 어린잎채소 재배 적정 위치 선발)

  • Kim, Jae Kyung;Kim, Il Seop;Kang, Ho Min;Choi, Ki Young
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.286-292
    • /
    • 2019
  • This study aimed to investigate the suitable of layer on growth of six baby leaf vegetables using existing facilities and equipment in rice seedling nursery. Three kinds of Lactuca(lettuce 'Jinppallola' and 'Romain white', and indian lettuce), two of Brassica(tatsoi and red tatsoi) and amaranth were used as the materials. After sowing, the rice seedling tray was placed in multi bench system($L120{\times}W60{\times}H195cm$, 10th floor), which were low(1st) layer above 15cm, middle(4th) layer above 115cm and high(7th) layer above 175cm apart from ground. Irrigation was sprayed 2~3 times a day using a automatic irrigation system. The growth characteristics and leaf color were investigated when leaf vegetables were reached the optimum size(within 10cm of plant height). During the culture periods(29th Jun.~31th Jul. 2017), daytime average temperature was $27.4{\sim}28.3^{\circ}C$ regardless of layers but solar irradiance was higher in the high-layer than low and middle-layer of 37% and 22%, respectively. The leaf length, leaf width and number of leaves in middle and high-layer have a tendency to increase but, fresh weight was different according to the layer. When the correlation between accumulation radiation and growth was analyzed, all of growth factor of Amaranth showed a high correlation and other cultivars showed correlation with each growth factors. As a result, It is suitable that amaranth and red tatsoi for high-layer, Indian lettuce and tatsoi for middle and high-layer and 'Romain white' for middle-layer. The growth of red lettuce 'Jinppallola' was good at low layer, but leaf color expression was poor. So the high layer is suitable for 'Jinppallola'.

Vegetative Propagation and Morphological Characteristics of Amelanchier spp. with High Value as Fruit Tree for Landscaping (정원용 유실수로서 가치가 높은 채진목속(Amelanchier spp.)의 형태적 특성 및 영양번식방법)

  • Kang, Ho Chul;Hwang, Dae Yul;Ha, Yoo Mi
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.111-119
    • /
    • 2018
  • This study was carried out to investigate the growth characteristics and propagation methods of the Korean native Amelanchier asiatica, A. arborea, and A. alnifolia as fruit trees for gardens. Due to the lack of recent research on Amelanchier spp., their superficial classification is still unclear and the names are being used interchangeably. The results are obtained as follows : A. arborea and A. alnifolia were globular type multi-stemmed shrubs. A 20-year-old tree of A. asiatica was 7.8m in height, with a 5.2m crown width, with one trunk. As for the morphological characteristics, leaves of A. asiatica were oblong, with an acuminate of, 6.1cm and 3.6cm width, but A. arborea and A. alnifolia had acute obovate leaves. The leaf size of A. alnifolia was the largest among the three species. The flower size of A. asiatica was bigger than that of A. arborea and A. alnifolia. In addition, its petals and flower clusters were also the largest among the three species. The flowering of A. asiatica initiated on April 21 and then bloomed for a duration of 24 days in Osan, while that of A. arborea and A. alnifolia initiated flowering on April 12 and then bloomed for a duration of 22 days in the same location. The fruit of A. arborea and A. alnifolia were green on May 10~12, it changed into purplish red on May 24~26, and its matured on June 1~3. The duration of fruit persistence of A. arborea and A. alnifolia were 48~50 days. On the other hand, A. asiatica showed greenish fruit on May 20, it became red on September 4, and had fallen by October 3. The fruit size was the largest at 1.03cm of height and 1.12cm of diameter in the A. arborea, followed by the big berry of A. alnifolia and the smallest fruit in the native, A. asiatica. It was difficult to root due to the hardwood cutting of A. arborea at a 40% rate of rooting. In the softwood cutting, the rooting rate of A. arborea was increased by the treatment with concentrated IBA, especially at 5,000 and 7,000ppm. The optimum date for cutting was on June 27, when the rooting rate was more than 80%. The most effective method for rooting of A. arborea was rootone or 7,000 ppm IBA treatment on June 27 softwood cuttings, which showed a rooting rate of over 80%.