• Title/Summary/Keyword: optimum location

Search Result 431, Processing Time 0.031 seconds

The propriety of Spatial Arrangement Condition of 119 Emergency Medical Service - Mainly Around H Town Area, Countrysid of Y city - (119지역대의 공간적 배치 현황의 적절성 -Y시 H면 지역을 중심으로-)

  • Yun, Jong-Geun;Choi, Kyu-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.374-380
    • /
    • 2017
  • In this study, we analyzed the situation of the 119 emergency medical service zone of H town, countryside of Y city from January 1st, 2015 to December 31st, 2016 and then, on the basis of this analysis, we investigated the present condition of the patient-transportation service of the 119 emergency medical service to provide the basic data in order for patients to use the emergency medical service more efficiently. We analyzed the data with SPSS 21.0 using frequency analysis and, after positioning the virtual 119 emergency medical service, we analyzed the data of the transportation time and transportation distance by using GIS. The results of this study show that the use of the 119 emergency medical service for people over 65 years old represents approximately 57% of the total number of patients transported, The average distance and time of the real moving reaction are 6.41 km and 11.86 min, respectively. The distance and time from the pick-up location to the hospital are 18.24 km and 21.52 min, respectively. Given the present position of the 119 emergency medical service, the results of this analysis using GPS show that the (average) distance and time from the 119 emergency medical service to Jang * Ri town are 9.12 km and 12 min, and the (average) total distance and time to arrive at the hospital after the emergency medical service picks up the patient are 36.83 km and 62 min, respectively. In the case of the virtual emergency medical service, the total distance and time required to arrive at the hospital after the emergency medical service picks up the patient are 27.71km and 50min, respectively. The results of this study showed that the present position of the 119 emergency service does not provide the optimum distance and time from the patient's location to the hospital. Therefore, we consider that the repositioning of the 119 emergency medical center is necessary, in order to reduce the time required for the emergency medical service to move to the patient's location and then bring the patient to the hospital.

An Experimental Study on Friction Welding and Heat Treatment of Engine Exhaust Valve Steels ( SCr4-21-4 N , SUH3-21-4-N (기관배기 밸브용 강 ( SCr4-21-4N , SUH3-21-4N ) 의 마찰압접과 열처리에 관한 실험적 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.79-87
    • /
    • 1978
  • This is an experimental study on friction welding and heat treatment of engine exhaust valve materials whose welding combination is SCr4 as stem to 21-4N as head and SUH3 to 21-4N. In this study, not only the experiments of friction welding under the selected optimum welding condition and the examination of the mechanical properties were carried out, but also the heat treatment of friction welded specimens under the two selected conditions was taken to obtain the better welding character, eliminating the latent stress and the hardness peak which appeared at the welded zones of heat resisting steel(21-4N, SUH3) and low alloyed steel ($SCr_4$) friction weldments. The results obtained by the experiments and consideration in this study are as follows: I) It was experimentally proved quite reasonable that 'speed=3,OOO rpm, heating pressure Pl=8 kg/ mm2, upsetting pressure p, = 20 kg/mm', heating time $t_1$ = 3 see, upsetting time TEX>$t_2$ = 2.5 sec' was selected as the optimum welding condition for friction-welding the engine exhaust valve materials $SCr_4$ to 21-4 Nand SUH 3 to 21-4 N. 2) The results of the previous study and this one on friction welding of such dissimilar materials as SUH 3-SUH 31, SCr 4-SUH 31, SCr 4-SUH 3, SUH 3-CRK 22, SCr4-21-4 Nand SUH3-21-4 N agreed with each other substantially in the friction welding characteristics at welded interface zones. 3) It was also certified quite satisfactory that '600\ulcornerCX30 min. Xroom air cooling' as an optimum heat treatment condition of the friction welded materials SCr 4-21-4 Nand SUH 3-21-4 N was experimentally determined to eliminate the latent stress and the hardness peak at welded zones. 4) About 20% of the tensile strength before heat treatment of friction welded specimens was decreased after heat treatment 600\ulcornerCX30 min. Xair cooling, but the location of fracture was moved from heat affected zone to parent $SCr_4$ & SUH3. 5) Microscopic examination of the weld joints friction-welded and heat-treated under the above mentioned conditions revealed that the weld zone is very narrow and has a fine grained intermixed structure without any welding defects. 6) The above mentioned conditions can be also utilized as friction welding parameters of the other dissimiar materials for engine valve production.

  • PDF

Studies on the Photosynthesis of Korean Ginseng 1. Seasonal Changes in Photosynthetic Ability of Youngaged Korean Ginseng (Panax ginseng C. A. Meyer) (고려인삼엽의 광합성능력에 관한 연구 -제 1 보 저년생 고려인삼 광합성능력의 계절적 변이-)

  • 조재성;원준연
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.29 no.1
    • /
    • pp.89-97
    • /
    • 1984
  • This study was carried out to investigate the effect of seasonal changes on some of the morphological and physiological characteristics, including the photosynthetic abilities and dark respiration, of young ginseng plants due to planting location under shading. The results obtained are as follows: 1. Seedlings and 2-year old plants planted in the back rows appeared to have broader leaf area, and their leaf weight greatly increased in September. Chlorophyll content was significantly reduced in September rather than in June and the plants in the back rows had more chlorophyll content than those in the front rows. 2. There was no difference in the light compensation point between the front and back rows in June, while in September the light compensation point of 2-year old ginseng leaves was much lower for plants in the back rows compared with those in the front rows. A difference in the light saturation point was not noticeable between plants in the front and back rows in June and September. But the light saturation point of 2-year old ginseng leaves at $15^{\circ}C$ was high in June, while it was high at $20^{\circ}C$ high in September. 3. Maximum photosynthetic ability was attained at $15^{\circ}C$ in June and at $20^{\circ}C$ in September. During June no significant difference in photosynthetic ability was found between plants in the front and back rows, but in September the amount of photosynthesis was significantly increased at the leaves of seedlings as well as 2-year old plants planted in the back rows. 4. The optimum temperature for maximum photosynthesis in 2-year old plants ranged from $14.0^{\circ}C$ to $14.5^{\circ}C$ in June and from $19.5^{\circ}C$ to $20.5^{\circ}C$ in September. However, the optimum temperature for maximum photosynthesis in the seedlings was from $21.2^{\circ}C$ to $21.6^{\circ}C$ in September, but a significant difference in the optimum temperature for the maximum photosynthesis in seedlings and 2-year old plants was not noticeable between the front and back rows. 5. The respiration rate was rather high in seedlings compared with 2-year old plants. During September the respiration rate in seedlings was much lower in the back rows than in the front rows. The rate of increase in the respiration of 2-year old plants was higher at September than June. The increase in respiration rate due to temperature was more significant in seedlings than 2-year old plants. 6. In September, the level of $Q_{10}$ in 2-year old plants was much lower than that found in seedlings. During June, 2-year old plants showed lower $Q_{10}$ levels at a temperature difference between $15^{\circ}C$ and $25^{\circ}C$; but in September this occurred at a temperature difference between $20^{\circ}C$ and $30^{\circ}C$.

  • PDF

The Effect of Form Factors and Control Types on Unsorted List Search for Full Touch Phone

  • Lee, Jong-Kee;Park, Jae-Kyu;Kim, Jun-Young;Choe, Jae-Ho;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.309-317
    • /
    • 2012
  • Objective: The aim of this paper is to inquire into the influences form factors and control types affect a search time and comfort at list menu of full touch phone. Background: Various studies have been proceeded that are related to the optimum touch area for enhancing usability of control and legibility in mobile touch device. In the environment of list menu which is widely used to provide various information effectively, however, not only comprehensive consideration for legibility and control is to be seek but also research for control type which is to scroll a list. Method: This study executed form factor experiment to inquire into the influence that font size, height of row and fixed area affect searching time and comfort in the while information processing even if the information on the list is unsorted in alphabetical order. Among the result of form factor experiment, control type experiment was executed by selecting shortest performance time, highest legibility comfort and control comfort. Control type experiment was implemented to figure out the influence which existing flicking type, scrolling bar type, newly established button page type and button raw types affect performance time and subjective comfort depending on location of the information. Results: Font size 12pt, height of row 7mm and fixed area 15mm was shortest performance time and got highest comfort and legibility score in form factor experiment. A Button page which was newly proposed type was shortest performance time and got highest comprehensive comfort in control type experiment. Conclusion: Form factor experiment showed similar results with the study through reading a long passage of character or controlling a grid icon type. However, height of row turned out to affect not only touch area for control but also legibility by ruling space between the lines. Button page type which was newly proposed showed shortest performance time and got highest comprehensive comfort. Because Button page type needs few finger movements than other control types and implements search in the fixed form, unlikely other type which list keeps moving. Application: This study should be applied in deciding form factors and control type for scroll when designing a list menu of full touch phone.

Aerodynamic noise reduction of fan motor unit of cordless vacuum cleaner by optimal designing of splitter blades for impeller (임펠라 스플리터 날개 최적 설계를 통한 무선진공청소기 팬 모터 단품의 공력 소음 저감)

  • Kim, Kunwoo;Ryu, Seo-Yoon;Cheong, Cheolung;Seo, Seongjin;Jang, Cheolmin;Seol, Hanshin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.524-532
    • /
    • 2020
  • In this study, noise radiated from a high-speed fan-motor unit for a cordless vacuum cleaner is reduced by designing splitter blades on the existing impeller. First of all, in order to investigate the flow field through a fan-motor unit, especially impeller, the unsteady incompressible Reynolds-Averaged Navier-Stokes (RANS) equations are numerically solved by using computational fluid dynamic technique. With predicted flow field results as input, the Ffowcs Williams-Hawkings (FW-H) integral equation is solved to predict aerodynamic noise radiated from the impeller. The validity of the numerical methods is confirmed by comparing the predicted sound pressure spectrum with the measured one. Further analysis of the predicted flow field shows that the strong vortex is formed between the impeller blades. As the vortex induces the loss of the flow field and acts as an aerodynamic noise source, supplementary splitter blades are designed to the existing impeller to suppress the identified vortex. The length and position of splitter are selected as design factors and the effect of each design factor on aerodynamic noise is numerically analyzed by using the Taguchi method. From this results, the optimum location and length of splitter for minimum radiated noise is determined. The finally selected design shows lower noise than the existing one.

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

A Study on the Design Improvement and Information Service of Bicycle Road Considering Environmental Factor (주변 환경요소를 고려한 자전거 도로 설계 개선 및 정보제공에 관한 연구)

  • Choi, Byoung-Gil;Park, Hong-Ki;Na, Young-Woo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • This study aimed to devise the method to construct safe and convenient bicycle road by considering the peripheral environmental factor related to using bicycle. Analyzing the existing design of bicycle road and construction case, this study established the method to design bicycle road that reflects site condition and presented the optimal design method for each type of bicycle road to construct safe and convenient bicycle road by analyzing the type of traffic accident for each type of bicycle road, surveying present situation and local survey. It was found that the optimum design of bicycle road for specification, width, curve radius, ascending slope, etc in consideration of peripheral environment and separating traffic between users of traffic means should be done by installing safety sign, safe facilities and separation facilities to design safe bicycle road. Further, the minimum traffic space of bicycle users and connection between bicycle roads should be ensured to design safe bicycle road. It is judged that information related to safety and convenience of bicycle road such as slope, route information, location of convenience facilities, information to the public traffic should be provided so as to activate the users of bicycle.

Development of Moisture Loss Index Based on Field Moisture Measurement using Portable Time Domain Reflectometer (TDR) for Cold In-place Recycled Pavements (휴대용 TDR 함수량계로 측정한 현장 함수비를 이용한 현장 상온 재활용 아스팔트 포장의 수분 감소계수 개발)

  • Kim, Yong-Joo;Lee, Ho-Sin David;Im, Soo-Hyok
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.139-145
    • /
    • 2011
  • The practice of asphalt pavement recycling has grown rapidly over the decade, one of which is the cold in-place recycling with the foamed asphalt (CIR-foam) or the emulsified asphalt (CIR-emulsion). Particularly, in Iowa, the CIR has been widely used in rehabilitating the rural highways because it significantly increases the service life of the existing pavement. The CIR layer is typically overlaid by the hot mix asphalt (HMA) to protect it from water ingress and traffic load and obtain the required pavement structure and texture. Most public agencies have different curing requirements based on the number of curing days or the maximum moisture contents for the CIR before placing the overlay. The main objective of this study is to develop a moisture loss index that the public agency can use to monitor the moisture content of CIR layers in preparation for a timely placement of the wearing surface. First, the moisture contents were measured in the field using a portable time domain reflectometry (TDR) device. Second, the weather information in terms of rain fall, air temperature, humidity and wind speed was collected from the same location. Finally, a moisture loss index was developed as a function of initial moisture content, air temperature, humidity and wind speed. The developed moisture loss index based on the field measurements would help the public agency to determine an optimum timing of an overlay placement without continually measuring moisture conditions in the field.

Studies on Intestinal Trematodes in Korea IX. Recovery Rate and development of Firbricola seoulensis in Experimental Animals (한국의 장흡충에 관한 연구 IX. 실험동물내에서의 Fibricola Seoulens양 충체위수률 및 발육)

  • 홍성종;이순형
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.224-233
    • /
    • 1983
  • An experimental study was carried out to observe the susceptibility of several kinds of laboratory animals to Fibricola seoulensis infection, a diplostomatid fluke of mammals. The metacercariae were obtained from the viscera of the snakes, Natrix tigrina lateralis and 50~2,000 in number each was artificially fed to a total of 127 animals; albino rats, mice, dogs, cats, rabbits and chickens. After 3 days to 8 weeks the animals were sacrificed and the recovery rate of worms as well as their maturity was observed. The results are as follows: 1. The overall worm recovery rates throughout the experimental period was highest in albino rats (40.0%) followed by mice (33.9%), cats (20.9%), dogs (11.4%), rabbits (0.05%) and chickens (0%). However, the recovery rates in the same host decreased as infection progressed longer and variable by the amount of metacercariae given. 2. From albino rats and mice, the highest recovery rates were obtained in 1,000 and 200-metacercariae infection groups respectively, and it is considered that such amount should be the optimum dose for experimental infection of these animals. 3. The main location of F. seoulensis in experimental animals was small intestine especially the duodenum. 4. The maturity index (No. mature worms/ No. examined) was 100% in albino rats and mice, while only 22.7% or 0% in dogs or cats respectively. From the results, it is concluded that albino rats and mice are the most susceptible hosts for F. seoulensis infection among six kinds of laboratory animals examined.

  • PDF

The Application of Geospatial Information Acquisition Technique and Civil-BIM for Site Selection (지형공간정보취득기술과 토목BIM을 활용한 부지선정 연구)

  • Moon, Su-Jung;Pyeon, Mu-Wook;Park, Hong-Gi;Ji, Jang-Hun;Jo, Jun-Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.6
    • /
    • pp.579-586
    • /
    • 2010
  • Due to the recent development of measuring technology and 3D programs, it has become possible to obtain various spatial data. This study utilizes the 2-dimensional data and 3-dimensional data extraction technology based on the existing empirical and statistical DB. The data obtained from geospatial data technology are integrated with civil engineering BIM to conduct the modeling of the topography of the target region and select the optimum location condition by using the cut and fill balance of the volume of earth. The target area is the land around Tamjin River, Jangheong-gun, Jeolla-do. The 3-dimensional topology linked with 3-dimensional mapping technology by using the orth-image and aerial LiDAR that uses aerial photo of the target area is visualized with Civil3D of AutoDesk. By using Civil3D program, the Thanks to the recent development of measuring technology and 3D programs, target area is analyzed through visualization and related data can be obtained for analysis. The method of using civil engineering BIM enables to obtain various and accurate information about the target area which is helpful for addressing the issues risen from the existing methodology. In this regard, it aims at searching for the alternatives and provides suggestions to utilize the information.