• 제목/요약/키워드: optimal placement

검색결과 368건 처리시간 0.027초

외란 소거법을 이용한 강인한 전력 계통 안정화 장치 설계 (Design of Robust Power System Stabilizers Using Disturbance Rejection Method)

  • 김도우;윤기갑;김홍필;양해원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1195-1199
    • /
    • 1998
  • In this paper a design method of robust power system stabilizers is proposed by means of robust linear quadratic regulator design technique under power system's operating condition change, which is caused by inner structure uncertainties and disturbances into a power system. It is assumed that the uncertainties present in the system are modeled as one equivalent signal. In this connections an optimal LQR control input for disturbance rejection, the output feedback gain for eliminating the disturbance are calculated. In this case. PSS input signal is obtained on the basis of weighted ${\Delta}P_e$ and $\Delta\omega$. In order to stabilize the overall control of system. Pole placement algorithm is applied in addition. making the poles of the closed loop system to move into a stable region in the complex plane. Some simulations have been conducted to verify the feasibility of the proposed control method on a machine to infinite bus power system. From the simulation results validation of the proposed method could be achieved by comparisons with the conventional PSS with phase lag-lead compensation.

  • PDF

Design of piezoelectric transducer arrays for passive and active modal control of thin plates

  • Zenz, Georg;Berger, Wolfgang;Gerstmayr, Johannes;Nader, Manfred;Krommer, Michael
    • Smart Structures and Systems
    • /
    • 제12권5호
    • /
    • pp.547-577
    • /
    • 2013
  • To suppress vibration and noise of mechanical structures piezoelectric ceramics play an increasing role as effective, simple and light-weighted damping devices as they are suitable for sensing and actuating. Out of the various piezoelectric damping methods this paper compares mode based active control strategies to passive shunt damping for thin plates. Therefore, a new approach for the optimal placement of the piezoelectric sensors/actuators, or more general transducers, is proposed after intense theoretical investigations based on the Kirchhoff kinematical hypotheses of plates; in particular, modal and nilpotent transducers are discussed in detail. Based on the proposed distribution a discrete design for modal transducers is implemented, tested and verified on an experimental setup. For active control the modal sensors clearly identify the eigenmodes, whereas the modal actuators impose distributed eigenstrains in order to reduce the transverse plate vibrations. In contrast to the modal control, passive shunt damping works without requiring additional actuators or auxiliary power and can therefore act as an autonomous system, but it is less effective compensating the flexible vibrations. Exemplarily, an acryl glass plate disturbed by an arbitrary force initialized by a loudspeaker is investigated. Comparing the different methods their specific advantages are highlighted and a significant broadband reduction of the vibrations of up to -20dB is obtained.

Investigation of Design Methodology for Impressed Current Cathodic Protection Optimum System

  • Yao, Ping;Wu, Jianhua
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.197-200
    • /
    • 2008
  • In this paper, physical scale modeling was employed to identify the configurations of ICCP system and the electric field signatures. Computational boundary element modeling technique has been used to simulate the performance of the CP system and to predict the associated electric fields signatures. The optimization methods combined with the computer models and physical scale modeling will be presented here, which enable the optimum system design to be achieved both in terms of the location and current output of the anode but also in the location of reference electrodes for impressed current cathodic protection(ICCP) systems. The combined methodology was utilized to determine optimal placement of ICCP components (anodes and reference electrodes) and to evaluate performance of ICCP system for the 2%, 10% and 14% wetted hull coatings loss. The objective is to design the system to minimise the electric field while at the same time provide adequate protection for the ship. The results show that experimental scale modeling and computational modeling techniques can be used in concert to design an optimum ICCP system and to provide information for quickly analysis of the system and its surrounding environment.

Nonlinear control of a 20-story steel building with active piezoelectric friction dampers

  • Chen, Chaoqiang;Chen, Genda
    • Structural Engineering and Mechanics
    • /
    • 제14권1호
    • /
    • pp.21-38
    • /
    • 2002
  • A control algorithm combining viscous and non-linear Reid damping mechanisms has been recently proposed by the authors to command active friction dampers. In this paper, friction dampers and the proposed algorithm are applied to control the seismic responses of a nonlinear 20-story building. Piezoelectric stack actuators are used to implement the control algorithm. The capacity of each damper is determined by the practical size of piezoelectric actuators and the availability of power supply. The saturation effect of the actuators on the building responses is investigated. To minimize the peak story drift ratio or floor acceleration of the building structure, a practical sequential procedure is developed to sub-optimally place the dampers on various floors. The effectiveness of active friction dampers and the efficiency of the proposed sequential procedure are verified by subjecting the building structure to four earthquakes of various intensities. The performance of 80 dampers and 137 dampers installed on the structure is evaluated according to 5 criteria. Numerical simulations indicated that the proposed control algorithm effectively reduces the seismic responses of the uncontrolled 20-story building, such as inelastic deformation. The sub-optimal placement of dampers based on peak acceleration outperforms that based on peak drift ratio for structures subjected to near-fault ground motions. Saturation of piezoelectric actuators has adverse effect on floor acceleration.

이미지 컬러채널을 이용한 워게임 합성환경 객체 배치방법 (An Object Placement Method for War Game Synthetic Environment Using Color Channels of Image)

  • 하동원;이태억
    • 한국게임학회 논문지
    • /
    • 제13권2호
    • /
    • pp.111-118
    • /
    • 2013
  • 미군은 이기종간 워게임 환경통합과 최단시간 모의환경 생성을 위해 SE-CORE와 공통가상 환경을 개발하고 발전시키고 있다. 한국도 실정에 맞는 SEDRIS 연구 등을 진행하고 있지만 여전히 풀어야 할 문제가 많다. 이 연구는 합성자연환경에서 수작업으로 행해지는 객체 배치 과정을 이미지 채널 정보를 통해 반자동화 하는 방법을 제안하고 있으며, 이는 합성환경 생성을 빠르게 하고 이기종간 자료공유를 수월하게 할 수 있게 한다. 향후 추가적인 연구가 진행되면 다양한 정보수집 장치로부터 입력된 자료들을 합성전장환경에 적용할 수 있는 자동화 기술 개발도 가능할 것으로 보인다.

버블패킹방법을 이용한 2차원 자동격자 생성 및 재구성 알고리듬 개발(I) -선형 해석- (Development of Algorithm for 2-D Automatic Mesh Generation and Remeshing Technique Using Bubble Packing Method (I) -Linear Analysis-)

  • 정순완;김승조
    • 대한기계학회논문집A
    • /
    • 제25권6호
    • /
    • pp.1004-1014
    • /
    • 2001
  • The fully automatic algorithm from initial finite element mesh generation to remeshing in two dimensional geometry is introduced using bubble packing method (BPM) for finite element analysis. BPM determines the node placement by force-balancing configuration of bubbles and the triangular meshes are made by Delaunay triangulation with advancing front concept. In BPM, we suggest two node-search algorithms and the adaptive/recursive bubble controls to search the optimal nodal position. To use the automatically generated mesh information in FEA, the new enhanced bandwidth minimization scheme with high efficiency in CPU time is developed. In the remeshing stage, the mesh refinement is incorporated by the control of bubble size using two parameters. And Superconvergent Patch Recovery (SPR) technique is used for error estimation. To verify the capability of this algorithm, we consider two elasticity problems, one is the bending problem of short cantilever beam and the tension problem of infinite plate with hole. The numerical results indicate that the algorithm by BPM is able to refine the mesh based on a posteriori error and control the mesh size easily by two parameters.

Dimensioning of linear and hierarchical wireless sensor networks for infrastructure monitoring with enhanced reliability

  • Ali, Salman;Qaisar, Saad Bin;Felemban, Emad A.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권9호
    • /
    • pp.3034-3055
    • /
    • 2014
  • Wireless Sensor Networks have extensively been utilized for ambient data collection from simple linear structures to dense tiered deployments. Issues related to optimal resource allocation still persist for simplistic deployments including linear and hierarchical networks. In this work, we investigate the case of dimensioning parameters for linear and tiered wireless sensor network deployments with notion of providing extended lifetime and reliable data delivery over extensive infrastructures. We provide a single consolidated reference for selection of intrinsic sensor network parameters like number of required nodes for deployment over specified area, network operational lifetime, data aggregation requirements, energy dissipation concerns and communication channel related signal reliability. The dimensioning parameters have been analyzed in a pipeline monitoring scenario using ZigBee communication platform and subsequently referred with analytical models to ensure the dimensioning process is reflected in real world deployment with minimum resource consumption and best network connectivity. Concerns over data aggregation and routing delay minimization have been discussed with possible solutions. Finally, we propose a node placement strategy based on a dynamic programming model for achieving reliable received signals and consistent application in structural health monitoring with multi hop and long distance connectivity.

전방십자인대 재건술 - 잔류조직 보존술식 - (ACL Reconstruction - Remnant Preserving Technique -)

  • 이병일;천동일
    • 대한관절경학회지
    • /
    • 제13권2호
    • /
    • pp.97-104
    • /
    • 2009
  • Optimal treatment of the torn anterior cruciate ligament (ACL) remains controversial. The complexity of surgically reproducing the natural biomechanical and anatomical function of the ACL has led to a diversity of reconstructive procedures. Controversy continues to exist regarding the best reconstructive procedure for the ACL deficient knee, but currently, there is no ideal method. Because of the increased frequency of ACL injury and the functional impairment resulting from that, the role of mechanoreceptors in the ACL recently has attracted considerable attention. Proper reconstruction of the ruptured ACL does not always have good results. Success after operation may depend not only on the mechanical stability but also on the quality of recovery of proprioception. It is well known that most ACL are ruptured in proximal half and most mechanoreceptors have been reported to be located in the subsynovial layer and near the tibial insertion of the ACL. Expected roles of tibial remnant is to enhance the revascularization and cellular proliferation of the graft, to preserve proprioceptive function, and to be able to acquire anatomical placement of the graft without roof impingement. The remnant of the ruptured ACL has been removed to clearly visualize the ACL footprint or decrease the risk of impingement and Cyclops lesion in most current techniques for ACL reconstruction. Therefore it seems reasonable to assume that preserving the tibial remnant as much as possible as a source of reinnervation, if technically possible without causing impingement, would be of potential benefit to the patient. In addition, it will facilitate the vascular ingrowth and ligamentization of the grafted ACL.

  • PDF

상수관망시스템의 단수용량 최소화를 위한 단수구역 기반 최적 밸브위치 선정 (Segment-based Optimal Valve Placement for Minimizing Water Suspension in Water Distribution Systems)

  • 임갑율;강두선
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.5-5
    • /
    • 2019
  • 상수관망시스템은 정수장으로부터 각 수요처에 음용수를 공급하기 위한 사회기반시설물이며, 광범위한 지역에 걸쳐 주로 지하에 시설물이 매설되어 있다. 상수관망시스템을 설계하고 운영함에 있어 노후화로 인한 유수율 저하, 갑작스런 수요량의 증가, 관로 파손 등 비정상상황에의 용수공급을 항상 대비하여야 하며, 이를 통한 지속적인 관리와 개량이 필요하다. 상수관망시스템에서 발생할 수 있는 다양한 비정상상황들 중 상수관망시스템 내 관로가 파손될 경우, 파손 관로의 보수 혹은 교체를 위해서는 해당 관로의 용수흐름을 일시적으로 차단할 필요가 있다. 이 과정에서 파손관로와 인접한 밸브를 차폐하게 되며, 이로 인해 용수공급이 중단되는 단수구역이 발생하게 된다. 단수구역은 파손 관로를 차폐함으로써 파손 관로와 함께 용수공급이 차단되는 직접고립지역과 직접고립지역으로 인해 의도치 않게 수원으로부터 물 공급이 차단되는 간접고립지역으로 구분할 수 있다. 따라서, 관 파손에 의한 단수용량을 정확히 산정하기 위해서는 시스템 내 설치된 밸브의 개수와 위치에 따른 직, 간접고립지역(단수구역)을 정확하게 산정할 필요가 있다. Jun and Loganathan(2007)은 단수구역을 직접고립지역과 간접고립지역으로 구분하여 정의하고 각각을 탐색하는 알고리즘을 제시한 바 있다. 본 연구에서는 기존 연구에서 제시한 간접고립지역 탐색 방법의 문제점을 파악하고, 이를 개선한 새로운 알고리즘을 제안 및 검증하였다. 또한, 개선된 알고리즘을 이용하여 상수관망시스템 내 최적 밸브위치를 결정하기 위해 단수용량과 밸브설치비용을 동시에 최소화하는 다목적 최적화 모형을 개발하였으며, 예시 관망을 이용하여 모의를 수행하고 결과를 분석하였다.

  • PDF

Robot-Assisted Thoracic Surgery in Non-small Cell Lung Cancer

  • Lee, Jun Hee;Hong, Jeong In;Kim, Hyun Koo
    • Journal of Chest Surgery
    • /
    • 제54권4호
    • /
    • pp.266-278
    • /
    • 2021
  • Lobectomy is the standard treatment for early non-small cell lung cancer. Various surgical techniques for lobectomy have been developed, and minimally invasive thoracic surgery, such as video-assisted thoracic surgery or robot-assisted thoracic surgery, has been considered as an alternative to conventional open thoracotomy. The recently robotic lobectomy technique has developed since the first case series was published in 2002. Several studies have reported that robotic lobectomy has comparable oncologic and perioperative outcomes to those of video-assisted thoracic surgery lobectomy and open lobectomy. However, robotic lobectomy remains a challenge for surgeons because of the steep learning curve, reduced tactile sensation, difficulty in port placement, and challenges in cooperation between the surgeon and assistant. Many studies have reported on robotic lobectomy, but few have presented surgical techniques for robotic lobectomy. In this article, the surgical techniques and optimal performance of robotic lobectomy are described in detail for all 5 types of lobectomy for surgeons beginning with robotic lobectomy.