• Title/Summary/Keyword: optical resolution

Search Result 1,461, Processing Time 0.028 seconds

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

REFOCUSING FOR ON-ORBIT MTF COMPENSATION OF REMOTE SENSING CAMERA

  • Jang Hong-Sul;Jeong Dae-Jun;Lee Seunghoon
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.601-603
    • /
    • 2005
  • Refocusing methods are used to compensate optical performance degradation of high resolution satellite camera during on-orbit operation. Due to mechanical vibration during launch and thermal vacuum environment of space where camera is exposed, the alignment of optical system may have error. The focusing error is dominant of misalignment and caused by the de-space error of secondary mirror of catoptric camera, which is most sensitive to vibration and space environment. The high resolution camera of SPOT, Pleiades and KOMPSAT2 have refocusing device to adjust focusing during orbital operation while QuickBird of US does not use on orbit refocusing method. For the Korsch type optical configuration which is preferred for large aperture space remote sensing camera, secondary mirror and folding mirror are available as refocusing element.

  • PDF

High Resolution Optical Spectra of HBC 722

  • Park, Sunkyung;Lee, Jeong-Eun;Kang, Wonseok;Sung, Hyun-Il;Lee, Sang-Gak;Green, Joel D.;Cochran, William D.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.80.2-80.2
    • /
    • 2014
  • We present the results of high resolution (R>35,000) optical spectroscopic monitoring observations of a new FU Orionis-like young stellar object, HBC 722. We observed HBC 722 with the Bohyunsan Optical Echelle Spectrograph (BOES) and Hobby-Eberly Telescope (HET) since November 26, 2010. HBC 722 is the FU Orionis-like object best characterized for the pre-outburst phase, and it provides the first opportunity to profile the burst phase of accretion across all wavelengths. We detected a number of lines such as $H{\alpha}$, $H{\beta}$, Fe II ${\lambda}$ 5018, Mg I ${\lambda}$ 5183, Na I D doublets, and metallic photospheric lines. In this work, we focus on the time variations of those spectral lines to understand the accretion process of HBC 722.

  • PDF

Video display System of Low Resolution that Landscape Lighting (경관 조명용 저해상도 영상표출 시스템)

  • Kim, Chang-Beom;Sun, Gi-Ju;Moon, Cheol-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1137-1138
    • /
    • 2008
  • The purpose of this study is to implement a landscape lighting system that displays full color video by precisely controlling the R, G, B (Red, Green, Blue) LEDs which have a resolution of 256 each. The system implemented in this study consists of a PC, MASTER, SLAVEs and MODULEs. The PC sets the various landscape lighting displays, and the image files can be sent to the MASTER through a virtual serial port connected to the USB (Universal Serial Bus). The MASTER sends a sync signal to the SLAVE. The SLAVE uses the signal received from the MASTER and the landscape lighting display pattern.

  • PDF

Shear Thinning Effects by VII Added Lubricant with In-Situ Optical Viscometer

  • Jang Siyoul
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.215-223
    • /
    • 2003
  • Viscosity index improver (VII) is one of the major additives to the modern multigrade lubricants for the viscosity stability against temperature rise. However, it causes shear thinning effects which make the film thickness lessened very delicately at high shear rate $(over\;10^5\;s^{-1})$ of general EHL contact regime. In order to exactly verify the VII's performance of viscosity stability at such high shear rate, it is necessary to make the measurement of EHL film thickness down to $\~100nm$ with fine resolution for the preliminary study of viscosity control. In this work, EHL film thickness of VII added lubricant is measured with the resolution of $\~5nm$, which will give very informative design tool for the synthesis of lubricants regarding the matter of load carrying capacity at high shear rate condition.

  • PDF

Three-Dimensional Microfabrication with Nano Resolution Using Two-Photon Absorption of Femto-Second Laser (극초단 펄스 레이저의 이광자흡수를 이용한 나노분해능의 3차원 마이크로 구조 제작)

  • Yi, Shin-Wook;Lee, Seong-Ku;Kong, Hong-Jin;Park, Sang-Hu;Jeong, Chang-Gyun;Taewoo Lim;Yang, Dong-Yol
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.64-65
    • /
    • 2003
  • Stereo-lithography using the two photon absorption(TPA) makes micro structures with great resolution. The technique is applied to correcting photomask, 3-D photonic crystal, 3-D optical storage, 3-D lithography and so on. In contrast to a conventional stereo-lithography with single-photon absorption which has a size problem caused by the geometrical diffraction limit, the stereo-lithography with TPA has no size limit. (omitted)

  • PDF

Stray Light Analysis of High Resolution Camera for a Low-Earth-Orbit Satellite

  • Park, Jun-Oh;Jang, Won-Kweon;Kim, Seong-Hui;Jang, Hong-Sul;Lee, Seung-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.52-55
    • /
    • 2011
  • We discuss the effect of stray light on a high-precision camera in an LEO(Low Earth Orbit) satellite. The critical objects and illumination objects were sorted to discover the stray light sources in the optical system. Scatter modeling was applied to determine a noise effect on the surface of a detector, and the relative flux of a signal and noise were also calculated. The stable range of reflectivity of the beam splitter was estimated for various scattering models.

Compact near-eye display for firefighter's self-contained breathing apparatus

  • Ungyeon Yang
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.1046-1055
    • /
    • 2023
  • We introduce a display for virtual-reality (VR) fire training. Firefighters prefer to wear and operate a real breathing apparatus while experiencing full visual immersion in a VR fire space. Thus, we used a thin head-mounted display (HMD) with a light field and folded optical system, aiming to both minimize the volume for integration in front of the face into a breathing apparatus and maintain adequate visibility, including a wide viewing angle and resolution similar to that of commercial displays. We developed the optical system testing modules and prototypes of the integrated breathing apparatus. Through iterative testing, the thickness of the output optical module in front of the eyes was reduced from 50 mm to 60 mm to less than 20 mm while maintaining a viewing angle of 103°. In addition, the resolution and image quality degradation of the light field in the display was mitigated. Hence, we obtained a display with a structure consistent with the needs of firefighters in the field. In future work, we will conduct user evaluation regarding fire scene reproducibility by combining immersive VR fire training and real firefighting equipment.

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.