• Title/Summary/Keyword: optical element

Search Result 682, Processing Time 0.023 seconds

Finite Element Study on the Micro-cavity Effect in OLED Devices

  • Lee, Hyeongi;Hwang, Youngwook;Won, Taeyoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.23-28
    • /
    • 2014
  • In this paper, we discuss on the optimal design scheme of the bilayer OLED (Organic Light Emitting Diodes) with micro-cavity structure. We carried out the optical simulation on the OLED device and calculated optimal scale of devices with taking the micro-cavity effect into account. Our emission model is based upon an ensemble of radiating dipole antennas. Consequently, we applied Maxwell's equation to this sequence, followed by the analysis on the electrical behaviors of OLED device using Poisson's equation. It contains carrier injection and transportation mechanism. In this process, we found out the thickness of each layer can affect the recombination rate at the emission layer. Therefore, we optimized the thickness of each layer to improve the efficiency of the device.

Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane Micropump (열공압 방식의 polydimethylsiloxane 마이크로 펌프의 제작 및 특성)

  • 김진호;문민철;김주호;김영호;김한수;한경희;김용상
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.342-346
    • /
    • 2004
  • A thermopneumatic-actuated polydimethylsiloxane (PDMS) micropump has been fabricated and their properties are characterized. The diffusers are used as a flow-rectifying element instead of passive check valves. The advantages of the proposed microvalve are of the low cost fabrication process and the transparent optical property using PDMS and indium tin oxide (ITO) glass. We presented the PDMS micropump that is easily integrated with the in-channel PDMS microvalves on the same substrate. The flowrate of the micropump increases linearly as the applied pulse voltage to the ITO heater increases. The fabricated ITO heater resistance is 6.54k$\Omega$. The peak of the flow rate is observed at the duty ratio of 10% for the applied pulse voltage of 55V at 6Hz and the maximum flow rate of 78nl/min is measured.

Analysis of Polarization Mode Dispersion in Nonlinear Optical Pulse propagation by SS-FEM adopting Approximated Sparse Matrix (희귀 행렬 근사 S-FEM을 이용한 비선형 광펄스의 편광 모드 분산 해석)

  • 한대우;이호준;정백호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.6A
    • /
    • pp.825-832
    • /
    • 2000
  • 광섬유 통신 시스템이 고속화되고 장거리를 전송하게 될 수록 편광모드 분산의 중요성은 더욱 부각되어 있다. 따라서 본 논문에서는 복굴절 광섬유에서 비선형 광펄스의 전파특성을 편광 모드 분산의 영향을 고려하여 시뮬레이션하였으며 이러한 현상이 발생되는 것을 알 수 있었다. 그리고 광섬유 비션형성에 의해서 GVD(Group Velocity Dispersion)와 마찬가기로 PMD(Polarization Mode Dispersion)에서도 부분적인 보상 현상이 나타남을 수치 결과를 통해 알 수 있었다. 이러한 광 전송 시뮬레이션을 구현하기 위해서 기존의 단계분할 푸리에 방식 (SS-FM, Split-Step Fourier Method)보다 장거리 전송시 오차의 발생이 적은 단계 분할 유한 요소법)SS-FEM, Split-Step Finite Element Method)을 적용하였으며, 또한 그 단점인 수행 속도를 개선한 희귀 행렬 근사 단계 분할 유한 요소법을 제안하였다. 그 결과 제안된 방법이 기존의 푸리에 연산법이나 일반적인 유한 요소법과 비교하여 더 빠른 수행 속도를 나타내는 것을 알 수 있었다.

  • PDF

A Study on the Influence of Pure Iron Purity of Electric Lens on the Electron Beam Control (전자빔 가공기의 전자렌즈 순철순도가 빔 제어에 미치는 영향)

  • Lee Chan-Hong;Ro Seung-Kook
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.149-153
    • /
    • 2005
  • The electron beam machining provides very high resolution up to nanometer scale, hence the E-beam writing technology is rapidly growing in MEMS and nano-engineering areas. In the optical column of the e-beam writer, there are several lenses condensing and focusing electron beams from electron gun with fringing magnetic fields. The polepieces of these lenses are usually made with high purity iron which is hard to fabricate and very expensive. In this paper, the possibility of using polepiece of object lens composed with pure iron and low carbon steel was examined to reduce cost. The magnetic field at object lens was calculated with finite element method, and practical focusing qualities of SEM pictures were observed comparing for the object lens polepieces with pure iron and two type of composed with low carbon steel.

  • PDF

Influences of Injection Molding Conditions on the Birefringence of a Disk (사출성형 조건이 디스크의 복굴절에 미치는 영향)

  • Park M.G.;Lee D.H.;Lee H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.305-309
    • /
    • 2005
  • A computer code was developed to simulate all three stages of the injection molding process ? filling, packing and cooling by finite element method. The constitutive equation used here was compressible Leonov model. The PVT relationship was assumed to follow the Tait equation. The flow-induced birefringence was related to the calculated flow stresses through the linear stress-optical law. Based on the simulation, the Taguchi method was used to investigate the influences of injection molding conditions on the birefringence of a center gate disk. In addition, the optimal processing conditions were selected to minimize the birefringence and the birefringence difference along the positions of the disk.

  • PDF

Admittance Analysis for Piezo Shunt Circuit with Application to CD-ROM Main Base (CD-ROM 메인 베이스에 적용한 압전 션트 회로의 어드미턴스 해석)

  • Kim, Heung-Soo;Park, Jong-Sung;Choi, Seung-Bok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, vibration suppression of a CD-ROM main base with piezoelectric shunt circuit is studied. Admittance is introduced to predict the performance of piezoelectric shunt damping. Numerical admittance obtained by commercial finite element code, ANSYS, correlates well with experimentally measured one. Multi-mode piezoelectric shunt damping is realized based on the target mode and frequencies obtained by the admittance analysis. Experimental results prove that admittance of the piezoelectric structure is capable of predicting the performance of piezoelectric shunt damping and the vibration of the main base with the piezoelectric patches is reduced effectively.

  • PDF

Design of All-SiC Lightweight Secondary and Tertiary Mirrors for Use in Spaceborne Telescopes

  • Bae, Jong-In;Lee, Haeng-Bok;Kim, Jeong-Won;Kim, Myung-Whun
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.60-68
    • /
    • 2022
  • We report on the design of the secondary and the tertiary mirrors used in lightweight assemblies made entirely of silicon carbide (SiC). The essential design points are weight reduction within the acceptable deformation of the mirror surface by gravity release, temperature change, and vibration during or after space launch. To find a design that achieves the target requirements, we established finite element models for various candidate designs and subjected each one to wave front error analyses along gravity directions and in operation temperatures. We also calculated the natural frequencies of the candidate assemblies. Our study suggested that a triangular cell with bipod flexure support can satisfy the target weight within the requirements.

Design of an Antireflection Coating for High-efficiency Superconducting Nanowire Single-photon Detectors

  • Choi, Jiman;Choi, Gahyun;Lee, Sun Kyung;Park, Kibog;Song, Woon;Lee, Dong-Hoon;Chong, Yonuk
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.375-383
    • /
    • 2021
  • We present a simulation method to design antireflection coating (ARCs) for fiber-coupled superconducting nanowire single-photon detectors. Using a finite-element method, the absorptance of the nanowire is calculated for a defined unit-cell structure consisting of a fiber, ARC layer, nanowire absorber, distributed Bragg reflector (DBR) mirror, and air gap. We develop a method to evaluate the uncertainty in absorptance due to the uncontrollable parameter of air-gap distance. The validity of the simulation method is tested by comparison to an experimental realization for a case of single-layer ARC, which results in good agreement. We show finally a double-layer ARC design optimized for a system detection efficiency of higher than 95%, with a reduced uncertainty due to the air-gap distance.

Technology Trends of Complex Modulation Spatial Light Modulator (복소변조 공간 광 변조 기술 동향)

  • Nam, J.;Kim, H.E.;Park, M.;Kim, Y.H.;Hwang, C.S.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.4
    • /
    • pp.81-88
    • /
    • 2022
  • In this study, we investigate the trends and prospects of spatial light modulation (SLM) technology that enables full complex modulation as a next-generation SLM. Current SLM technology, which is used as a key element in holography, augmented reality (AR), XR, and realistic displays, has performance limits that modulate only amplitude or phase. Notably, SLM capable of full complex modulation does not produce diffraction noise, unlike DC and twin image, and thus has a high-efficiency performance. In the future, the application field of next-generation SLM, which can be full-complex modulated, is expected to cover a wide range of holography-AR and-XR devices, optical artificial intelligence, and 6G free space optics communications, which will greatly contribute to the development of a super-realistic metaverse platform and service.

The Measurment Method of Small Deformation by using Holographic Interferometry (홀로그래픽 간섭법을 이용한 미소변형 측정법)

  • Kang, Young-June;Moon, Sang-Joon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.9
    • /
    • pp.52-58
    • /
    • 1995
  • Conventional measurement methods for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been performed as the methods of contact with objects to be inspect, but those methods have been taken relatively much time to be inspected. Holographic interferometry which is a non-contact optical measurement method using a coherent light can overcome these demerit, and also has an advantage that the quantitative measurement of small deformation for large areas can be accomplished at a time with high precision. In this paper the comparisons of the experimental results form holographic interferometry with those from the finite element method(FEM) and the analytical solutions of the elastic equation are discussed.

  • PDF