• Title/Summary/Keyword: operation type

Search Result 5,080, Processing Time 0.033 seconds

Best Measurement Capability and Standard Test Facility for the Water-level Gauges (수위계 표준시험장치 개발 및 최고측정능력에 관한 연구)

  • Shin, Gang-Wook;Hong, Sung-Taek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.10
    • /
    • pp.1012-1017
    • /
    • 2007
  • Rain data and water-level data are importantly used for dam operation at flood period. Because dams are directly controlled by the water-level data, the characteristic of the water-level gauges is necessary to be managed. Thus, we developed the standard test facility and method for testing the water-level gauges which are a float type, a supersonic type and a radar type. And we calculated the uncertainty of the standard test facility to maintain the accuracy of water-level gauges. Through development of this facility, we could obtain the characteristics and the calibration factor of the water-level gauges. And, this study showed that the standard test facility can be widely used for dam operation and basin management.

A Study on the Multi-resonant characteristics of Half-wave Resonant Type Multi-output ZVS HB Converter for the Plasma Display Panel (PDP용 반파 공진형 멀티출력 하프브리지 컨버터의 다중 공진특성에 관한 연구)

  • Lee, Jae-In;Son, Ho-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.6
    • /
    • pp.314-324
    • /
    • 2006
  • In recent years, having the advantages of being small, low in cost and high in efficiency, Half-wave resonant type, (having only one output diode), is used in ZVS Half-Bridge DC/DC converter. This paper presents the operation mode by multi-resonant factors in the Half-wave type multi-resonant converter with direct Buck chopper circuit operated in discontinuous current mode. To study the characteristics of a multi-resonant operation in steady-state, the characteristic impedances in each mode and safe operation-region(S.O.R) are reported. Computer simulation and experimental data are also riven to verify the theoretical results.

The design and analysis of Operational characteristic of Shielded Inductive Fault Current Limiter using high-$T_c$ Superconducting (고온초전도체를 이용한 차폐유도형 전류제한기의 설계 및 동작 특성해석)

  • Song, Jae-Joo;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.339-342
    • /
    • 2001
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed to search for the parameter to determine FCL operation, Fault current limiting operation can be executed as resistive or inductive type, which is determined by iron-core radius and the number of the primary coil turns. It was considered through this paper that the operation of each was compared and examined about the merit of each mode.

  • PDF

Network-type Cell Layout in Cellular Flexible Assembly Systems (셀형유연조립시스템에서의 네트웍형 셀배치)

  • 노인규;최형호
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.19 no.39
    • /
    • pp.63-73
    • /
    • 1996
  • With the success of flexible manufacturing systems (FMSs), flexible assembly systems (FASs) have been developed to automate factories further. As in a cellular FMS, a cellular FAS is considered as the most flexible and feasible assembly system configuration Because of the differences between manufacturing and assembly operation, the logic of cell formation and cell layout between a FMS and a FAS is not the same. Since the time for assembly operation is usually relatively short, the transfer time is thus very crucial for the performance of assembly systems. Therefore in assembly systems it is important to reduce the transfer time by sequencing operations efficiently and arranging machines like the sequences. The network-type layout is not only feasible for the machine arrangement based on operation sequences, but it has also layout flexibility. Therefore it is a reasonable layout configuration for cellular FASs. This paper presents a method for the cell layout based on the network-type layout in a cellular FAS design.

  • PDF

OpenVSLAM-based Cooperative Mobile AR System Architecture (OpenVSLAM 기반의 협력형 모바일 SLAM 시스템 설계)

  • Kook, Joongjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.136-141
    • /
    • 2022
  • In this paper, we designed, implemented, and verified the SLAM system that can be used on mobile devices. Mobile SLAM is composed of a stand-alone type that directly performs SLAM operation on a mobile device, and a mapping server type that additionally configures a mapping server based on FastAPI to perform SLAM operation on the server and transmits data for map visualization to a mobile device. The mobile SLAM system proposed in this paper is to mix the two types in order to make SLAM operation and map generation more efficient. The stand-alone type SLAM system was configured as an Android app by porting the OpenVSLAM library to the Unity engine, and the map generation and performance were evaluated on desktop PCs and mobile devices. The mobile SLAM system in this paper is an open source project, so it is expected to help develop AR contents based on SLAM in a mobile environment.

Developing Algorithm and Software for Efficient Operation of Rotary Type Surface Mounter (로터리형 표면실장기 효율적 운용을 위한 알고리듬 및 소프트웨어 개발)

  • Lee, Young-Hee;Kim, Jung;Kyoung, Kyu-Hyoung;Kim, Duck-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.8
    • /
    • pp.106-113
    • /
    • 1995
  • Surface mounters are used to mount the parts of electronic products on PCB(Printed Circuit Board. Those machines rely on high precision, high productivity, and software for accomodation of use. In this paper, two algorithms and a software which can give the users the acco-modation and high productivity for rotary type surface mounters are presented. The algo- rithms for development of of the software consider all factors which affect the effeciency of the operation. And the interface between user and machine for the accomodation of use can be achieved through the developed software.

  • PDF

A Typological Approach to the Community Management and Activation Plans for Apartment Complexes (아파트 단지 내 커뮤니티 운영 요소와 유형별 활성화 방안)

  • Kang, Soon-Joo;Lee, Bo-Bae;Kim, Jin-Young;Lee, Jong-Soo
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.109-120
    • /
    • 2014
  • This study is focused first on considering the factors which invigorate the community in an apartment complexes from the precedent study and on identifying the specific factors, necessary to run vigorously the community in an apartment complexes. After that, the study is devoted to develop the management scenarios suitable for each type, through identifying, on the basis of the factors, the operation type of the 15 apartment complexes, in which the Seoul city community experts exist. The study result could be the basis to find out an effective method to run and manage community facilities and programs according to the features of an apartment. On the study, the 1:1 in-depth interviews were conducted on the community experts, who supported the community management in the five autonomous districts in Seoul. The study found followings. 1) The community factors needed to be readjusted in respect of operation and management. to estimate how active the community in an apartment complexes was. After identifying the community operation factors, the factors in human resources, material resources, and financial resources, were figured out. 2) The five groups were drawn from the 15 apartment complexes. The grouping was based on the relation between the main operators in each factor which invigorates the community operation. As the result, the relationship between the main operators was vertical. In addition, the more operators. 3) Six types were drawn after grouping the operation status of the 15 apartment complexes on the factors which affected to the community invigoration: human resources, material resources, and financial resources. Consequently, the managing scenarios to invigorate the community in each type were suggested.

A Comparative Study on Heat Loss in Rock Cavern Type and Above-Ground Type Thermal Energy Storages (암반공동 열에너지저장과 지상식 열에너지저장의 열손실 비교 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.442-453
    • /
    • 2013
  • A large-scale high-temperature thermal energy storage(TES) was numerically modeled and the heat loss through storage tank walls was analyzed using a commercial code, FLAC3D. The operations of rock cavern type and above-ground type thermal energy storages with identical operating condition were simulated for a period of five consecutive years, in which it was assumed that the dominant heat transfer mechanism would be conduction in massive rock for the former and convection in the atmosphere for the latter. The variation of storage temperature resulting from periodic charging and discharging of thermal energy was considered in each simulation, and the effect of insulation thickness on the characteristics of heat loss was also examined. A comparison of the simulation results of different storage models presented that the heat loss rate of above-ground type TES was maintained constant over the operation period, while that of rock cavern type TES decreased rapidly in the early operation stage and tended to converge towards a certain value. The decrease in heat loss rate of rock cavern type TES can be attributed to the reduction in heat flux through storage tank walls followed by increase in surrounding rock mass temperature. The amount of cumulative heat loss from rock cavern type TES over a period of five-year operation was 72.7% of that from above-ground type TES. The heat loss rate of rock cavern type obtained in long-period operation showed less sensitive variations to insulation thickness than that of above-ground type TES.

SPECTRAL CHARACTERISTICS OF RESONANCE DISORDERS IN SUBMUCOSAL TYPE CLEFT PALATE PATIENTS (점막하 구개열 환자 공명장애의 스펙트럼 특성 연구)

  • Kim, Hyun-Chul;Leem, Dae-Ho;Baek, Jin-A;Shin, Hyo-Keun;Kim, Oh-Hwan;Kim, Hyun-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.4
    • /
    • pp.310-319
    • /
    • 2006
  • Submucosal type cleft palate is subdivision of the cleft palate. It is very difficult to find submucosal cleft, because when we exam submucosal type cleft palate patients, it seems to be normal. But in fact, there are abnormal union of palatal muscles of submucosal type cleft palate patients. Because of late detection, the treatment - for example, the operation or the speech therapy - for the submucosal type cleft palate patient usually becomes late. Some patients visited our hospital due to speech disorder nevertheless normal intraoral appearance. After precise intraoral examination, we found out submucosal cleft palate. We evaluated the speech before and after surgery of these patients. In this study, we want to find the objective characteristics of submucosal type cleft palate patients, comparing with the normal and the complete cleft palate patients. Experimental groups were 10 submucosal type cleft palate patients and 10 complete cleft palate patients who got the operation in our hospital. And, the controls were 10 normal person. The sentence patterns using in this study were simple 5 vowels. Using CSL program we evaluated the Formant, Bandwidth. We analized the spectral characteristics of speech signals of 3 groups, before and after the operation. In most cases, the formant scores were higher in experimental groups (complete cleft palate group and submucosal type cleft palate group) than controls. There were small differences when speeching /a/, /i/, /e/ between experimental groups and control groups, large differences when speeching /o/, /u/. After surgery the formant scores were decreased in experimental groups (complete cleft palate group and submucosal type cleft palate group). In bandwidth scores, there were no significant differences between experimental groups and controls.

Effectiveness Analysis of Roundabout Based on the Operation of Pedestrian Signal (보행신호 운영에 따른 회전교차로의 효과 분석)

  • Kim, Kyung-Hwan;Park, Byung-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • This study deals with the operation effectiveness of roundabout. The objective of this study was to analyze the operational effectiveness of roundabout based on the operation of pedestrian signal. For pursuing the above, VISSIM was as a traffic simulation program. this study gives particular attention to analyzing the 1,680 scenarios by operation of Pedestrian Signal(7 cases), roundabout type(2 cases), pedestrian volume(8 cases) and entering volume(15 cases). The main results analyzed are as follows. First, the operational effectiveness analyzed by 2 type of 4-legged 1-lane roundabout and 6 type of 4-legged 2-lane were evaluated to be better than that by the others type. Second, the average delay time analyzed by operation of pedestrian signal were evaluated to be less than that by unsignalized pedestrian crossing. Finally, the average delay time analyzed by pedestrian crossing were decreased 8.18% than that by staggered pedestrian crossing in 4-legged 1-lane. However, the average delay time analyzed by staggered pedestrian crossing were evaluated to be decreased 36.53% than that by pedestrian crossing in 4-legged 2-lane.