• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.039 seconds

Impact test of a centrifugal pump used in nuclear power plant under aircraft crash scenario

  • Huang, Tao;Chen, Mengmeng;Li, Zhongcheng;Dong, Zhanfa;Zhang, Tiejian;Zhou, Zhiguang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1858-1868
    • /
    • 2021
  • Resisting an accidental impact of large commercial aircrafts is an important aspect of advanced nuclear power plant (NPP) design. Especially after the 9·11 event, some regulations were enacted, which required the design of NPPs should consider the accidental impact of large commercial aircrafts. Normal working of equipment is important for stopping reactor under an impact when an NPP is in operation. However, there is a lack of reliable analysis and research on the impact test of nuclear prototype equipment. Therefore, in order to study the response of the equipment under high acceleration impact, a centrifugal pump is selected as the research object to perform the impact test. A horizontal half-sinusoidal pulse wave was applied to the working pump. The test results show that the horizontal response of the motor and flange is greater compared to other parts, as well as the vertical response of the coupling. The stress response of the pump body support and motor support is high, hence these parts should be considered in the design of the pump. Finally, combined with the damage and stress evaluation results of the pump under different amplitudes, the ultimate impact acceleration that the pump can withstand is given.

Development of a Lifetime Test Bench for Robot Reducers for Fault Diagnosis and Failure Prognostics (고장 진단 및 예지가 가능한 로봇용 감속기 내구성능평가 장치 개발)

  • Shin, Ju Seong;Kim, Ju Hyun;Kim, Jong Geol;Jin, Maolin
    • Journal of Drive and Control
    • /
    • v.16 no.3
    • /
    • pp.33-41
    • /
    • 2019
  • This study presents the development of a lifetime test bench for the strain wave reducer which is a precision gear reducer of the robot to realize fault diagnosis and failure prognostics. To this end, the lifetime test bench was designed to detect the vertical forward/reverse direction rotation load. Through the lifetime test bench, it is possible to apply the same load spectrum from robot working scenarios. We developed a data integration gateway for fault data collection. Through the development of dedicated software for fault diagnosis and failure prognostics, these data from vibration, noise and temperature sensors were collected and analyzed along with the operation of the lifetime evaluation.

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

Performance Verification of the Micro-Vibration Isolation Equipment by Qualification Tests (인증시험을 통한 위성용 미소 진동 저감 장치 성능 검증)

  • Mun Shin Jo;Yeon Hyeok Park;Hyun Ung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.5
    • /
    • pp.103-111
    • /
    • 2024
  • A spaceborne cryogenic cooler is known to undesirable microvibration disturbances during its on-orbit operation, which is one of the main sources that degrades the image quality of an observation satellite with a high resolution. Several types of vibration isolation systems based on passive approaches have been developed for reducing such microvibration of a linear cooler. A dual coil-spring-type passive isolator was developed. To verify its performance and structural characteristics, transmissibility measurement and modal survey were performed with properly designed dummy instead of a cooler. Results were then used as pass/fail criteria before/after each test. To verify structural and thermal stability of the dual coil-spring-type passive isolator for launch and on-orbit environment, vibration (random and sinusoidal) test, shock test, and thermal cycle test were performed successfully.

Relationship of Test Methods of Impact Absorbing Effect of Floors from a viewpoint of Safety in Accidental Collisions (인체충돌시 바닥의 안전성에 관한 시험방법간 연관성 분석)

  • Kim, Sang-Heon;Ji, Suk-Won;Yoon, Jung-Sik;Choi, Soo-Kyug;Seo, Chee-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • Since the study of building performance design was first undertaken by Building Research Station in 1930s, the results of such study has been reported from many parts of the world, building construction codes and standards have been revised based on performance in advanced nations as well in Korea, and various performance certification systems are in operation. The purpose of this study is to build a database of performance certification systems to investigate the co-relationship of various test methods related to the same test items. As test methods for case study, we selected test methods involving collision of the human body. Through analysis of Critical fall height test of EN 1177 and Head Model test of JIS A 6519 about 8 species of floor test-bodies, it was found that there are limits of application in terms of the depth and strength of cushion. Furthermore, although the measured physical parameters are the same, when the co-relationship between test methods is uncertain, the various physical parameters may not be compatible with the results.

A Study on the Development, Performance and Reliability Certification for Fire Detection System in Outdoor Area (옥외형 화재경보시스템의 개발과 성능시험에 관한 연구)

  • Baek, Dong-Hyun;Ghil, Min-Sik
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper is concerned with the Performance and Reliability Certification for fire detection system in outdoor area such small and middle sized cultural assets, natural monument and outdoor facilities. Especially, if a fire were to occur in vulnerable area, it is difficulty to detect a fire. therefore we propose a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. for Adoption of Intelligent Fire Detection System with movable and unmanned function breaking from the existing Conventional Fire Detection System, this Range of R&D includes the Performance test, Function test, Field test, Flame Detection test and EMI/EMS Compliance test. the Result data of Performance test, Function test and Field test is generally good during 3 months. also we checked that thermal variation test and EMI/EMS compliance test are good result data within allowable range. As a result of general test, we verified improvement results that the measure distance of fire detection extend 75 m, the Power of waiting time increase 4 hours, the Power of operation time increase 3 days and the context awareness with video as well as sensors.

On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

  • Kim, Jong-Bum;Jeong, Ji-Young;Lee, Tae-Ho;Kim, Sungkyun;Euh, Dong-Jin;Joo, Hyung-Kook
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1083-1095
    • /
    • 2016
  • The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V&V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodiumshowed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

Development of Continuous Capture Test Architecture in the Boundary Scan (경계면스캔에서의 연속캡쳐 시험구조 개발)

  • Jhang, Young-Sig;Lee, Chang-Hee
    • The KIPS Transactions:PartA
    • /
    • v.16A no.2
    • /
    • pp.79-88
    • /
    • 2009
  • In boundary scan architecture, test stimuli are shifted in one at a time and applied to the on-chip system logic. The test results are captured into the BSR and are examined by subsequent shifting. In this paper, we developed a continuous capture test architecture and test procedure using TPG based on boundary scan is used to performance test. In this architecture, test patterns of TPG are applied to CUT with system clock rate, and response of CUT is continuously captured by CBSR(Continuous Capture Boundary Scan Register) at the same rate and the captured results is shifted to TDO at the same rate. The suggested a continuous capture test architecture and test procedure is simulated by Altera Max+Plus 10.0. The simulation results shows the accurate operation and effectiveness of the proposed test architecture and procedure.

Economical Evaluation Based on Method of Coagulation with GAC Adsorber Operation (활성탄 흡착지의 운영시 응집 방법에 따른 경제성 평가)

  • Hong, Seongho;Sung, Dae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.473-479
    • /
    • 2005
  • Applying enhanced coagulation is not uncommon not only to improve water quality but also to obtain economical advantages in water treatment. In this study, the economical evaluation was investigated with considering dosage of coagulant, produced sludges and usage of activated carbon with two different water sources. To simulate the granular activated carbon(GAC) adsorber mini-column test was adapted. Even if there were some variation according to the source waters, the life time of GAC was extended 60 to 110days with adding 2.5 to 3 times of coagulant in enhanced coagulation. With assumption of changing GAC adsorber at 50% of breakthrough the total treatment cost can be reduced to range from 25% to 44% with adapting the enhanced coagulation. The obtained value can not be generalized because the value can be varied by water quality and cost of the GAC or coagulant. However, the evaluation can be basis starting point to find optimum operation methods for the drinking water treatment which has plan to adapt GAC adsorber.

Gasification melting characteristics of Automobile shredder residue in 5t/d shaft pilot plant (5톤/일 shaft형 pilot plant에서 자동차 폐차 잔재의 가스화 용융 특성)

  • Roh, SeonAh;Kim, WooHyun;Yun, JinHan;Hong, ByeongKwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.160-160
    • /
    • 2010
  • ELVs (End-of-Vehicles) in Korea incrasease continusely because of increase of used car. Automobile Shredder Residue (ASR) is final product of ELVs (End-of-Vehicles) after recycling. Automobile Shredder Residue are composed of light and heavy fluffs and soil/dust. In this study, 5 ton/day pilot plant of shaft type has been designed and constructed and 15 times of test run were performed. For the stable operation, operation conditions such as the amount of fed ASR and cokes, air flow and temperature in the gasification melting system have been changed and the composition of the produced gas such as $H_2$, CO and $CH_4$ and air pollution compound including dioxin discharged from the stack have been analyzed.

  • PDF