• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.033 seconds

Biochemical Analysis of the seamen's blood and urine before & after the ocean navigation (원양항해 전과 후 선원의 혈액 및 소변의 생화학적 분석)

  • Ha Hae-Dong;Moon Serng-Bae;Jun Seung-Hwan;Jeong Eun-Seok;Kim Jae-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.5-11
    • /
    • 2006
  • Urinalyses have been conducted for 28 seamen in K University's training ship and Creatine and Uric acid turned out to be higher in all ages, which can be inferred that on-deck environment has caused negative impact on kidney and/or malfunction. In addition, TC arid HDL-C, LDL-C has decreased, however, TG has increased after the navigation. All different positions including oater, crew, decker, engineer and radio part showed the similar pattern. TC and HDL-C has decreased in 30s, 40s and TG has increased in 30s. A few of the 30's show extremely high TG rates so Hyperlipidemia is suspected. 7 members fumed out positive for UBG test and 5 positive for PRO test. Especially there was only one UBG positive before the navigation but, 7 members has become positive, which means the one-month ocean navigation has definite impact on the liver cell function.

  • PDF

Test-bed Operation for Nation-wide Interoperable Transportation Card (전국호환 교통카드를 위한 테스트베드 운영)

  • Han, Ho-Hyeorn;Jee, Dong-Mok;Park, Ha-Na;Kim, Hye-Hyeon;Kim, Tae-Hee;Maeng, Jae-Hwan;Lee, Ki-Han
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.1-13
    • /
    • 2010
  • In this paper, we describe the result of the test-bed on Nation-wide Interoperable Transportation System connected with Interoperable Traffic Information Collection System, which was developed by Korea Financial Telecommunications & Clearings, KOREAIL NETWORKS, HiPlusCard and Samsung SDS. we constructed Nation-wide Interoperable Transportation System on 4 downtown bus routes, 20 stations on line 1 subway, 2 stations of a train and 2 sections of the Honam highway in Gwangju and Interoperable Traffic Information Collection System in Seoul University IC Card Center. So we operated that by 480 Several staff were given a test card and asked to try it for about 6 months. This test-bed is for demonstrates the accuracy, safety and credibility of the Nation-wide Interoperability standard technology and it can be applied to all of transportation practically. When the staffs contact the card to Purchase terminal, the card performs transaction with Purchase SAM in the terminal, then transactions ara used to calculate in Settlement system and Interoperable Traffic Information Collection System. Through the test-bed, we examined this process and found unexpected problems happening during the test operation and have successfully solved them. In addition, the results of the test-bed let us know what additional improvement might be required for System. The successful run of the test-bed was verified by an evaluation of the test-bed staff and a public survey.

Study on Properties and Accelerated Life-time Test of Rubber O-ring by Temperature Stress

  • Shin, Young-Ju;Kang, Bong-Sung;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.48-54
    • /
    • 2006
  • In this thesis, accelerated life test (ALT) method and procedure for rubber O-ring are applied to assure specified reliability of the products at guaranteeing the life of the products. Rubber O-ring is parts that keep intensity or make machine operation smoothly on attrition portion of machine and is used to prevent that oil is leaked. Usually. Rubber O-ring used NBR that is copolymer of acrylonitrile and butadiene. this are superior oil resistance, heat resistance, durability of abrasion, cold resistance, chemical resistance etc. The accelerated life test model for rubber O-ring are developed using the relationship between stresses and life characteristics of products. Using the accelerated life test method and the acceleration life test equipment which is developed, we performed life test, collected life data and analyzed the results of tests. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably.

  • PDF

Performance Analysis of the GPS Receiver System under Electromagnetic Test of the KSL V-I Upper-stage (KSLV-I 상단조립체의 전자파시험에서 GPS 수신기 시스템의 성능분석)

  • Moon, Ji-Hyeon;Kwon, Byung-Moon;Shin, Yong-Sul;Choi, Hyung-Don
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.161-169
    • /
    • 2008
  • This paper introduces test configuration and operation method for the GPS receiver system under electromagnetic test of KSLV-I upper-stage as a system qualification level and describes performance analysis of the test results. The GPS receiver system has clearly passed the electromagnetic test specifications of component level which is based on MIL-STD-461E through several design changes. Under electromagnetic test as a system qualification level, the GPS receiver system normally operates in spite of electromagnetic interferences with other systems. Performance of the GPS receiver system is also, not degraded on the condition of electromagnetic field incidence and electrostatic discharge. The KSLV-I GPS receiver system, as a result, is verified on the electromagnetic condition of the KSLV-I upper-stage.

  • PDF

Turbopump+Gas generator Open-loop coupled test (터보펌프+가스발생기 개회로 연계시험)

  • Kim, Seung-Han;Nam, Chang-Ho;Kim, Cheul-Woong;Moon, Yoon-Wan;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.125-128
    • /
    • 2008
  • As a interstage of the 30tonf level LOx/kerosene liquid rocket engine development, turbopump-gas generator open-loop coupled tests are performed. Test schematic and test results of open-loop coupled tests are presented. In engine system operation environment simulating combustion chamber by flow control orifice, chill-down procedure, startup characteristics, nominal operability of turbopump+gas generator open-loop coupled Test Plant are confirmed The results of open-loop coupled test were used for the preparation on turbopump+gas generator closed-loop test.

  • PDF

A Miniaturized Catadioptric Laser-Irradiation-Precision Test System

  • Liu, Huan;Sun, Hao;Wang, Chunyan
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.164-172
    • /
    • 2021
  • In this paper a catadioptric laser-irradiation-precision test system is designed, to achieve a high-precision laser-irradiation-accuracy test. In this system, we adopt the method of imaging the entire target surface at a certain distance to realize the measurement of laser-irradiation precision. The method possesses the advantages of convenient operation, high sensitivity, and good stability. To meet the test accuracy requirement of 100 mm/km (0.01%), the coma, field curvature, and distortion over the entire field of view should be eliminated from the optical system's design. Taking into account the whole length of the tube and the influence of stray light on the structure type, a catadioptric system with a hood added near the primary imaging surface is designed. After optimization using the ZEMAX software, the modulation transfer function (MTF) of the designed optical system is 0.6 at 30 lp/mm, the full-field-of-view distortion is better than 0.18%, and the energy concentration in the 10-㎛-radius surrounding circle reaches about 90%. The illumination-accuracy test results show that the measurement accuracy of the radiation hit rate is better than 50 mm when the test distance is 1 km, which is better than the requirement of 100 mm/km for the laser-irradiation-accuracy test.

A Study on a Quality Characteristics of Pressure Leak Test of Process Piping for Offshore Plant (해양플랜트 프로세스 배관 Pressure Leak Test의 품질 특성에 관한 연구)

  • Park, Chang-Soo;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.429-437
    • /
    • 2018
  • The process gas piping of the offshore plant can cause a massive explosion if the gas leakage occurs during operation. For the purpose of precaution of gas leakage accident, an air pressure test is performed on the process equipment tests using a test pump as much as the power to the piping inner side, mix 99% nitrogen gas and 1% helium gas. The purpose of the air pressure test is to check the work conformity process by handling and regulation for initial piping process, assembly, installation of module, welding, center alignment of the pipes assembling flange gasket in an unrestrained free state. In this paper, the regulation of the problematic air pressure test was analyzed and the solution criteria were established. And leakage tests of existing equipment were performed applying these solution methods. As a result, it was confirmed that there was no problem.

Operation performance analysis of Synthetic Test Circuit for Thyristor Valve Test of HVDC System (HVDC System의 Thyristor Valve Test를 위한 합성시험회로의 동작성능 분석)

  • Kim, Jong-Won;Han, Byung-Moon;Nho, Eui-Cheol;Baek, Seung-Taek;Chung, Yong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.303-304
    • /
    • 2011
  • 본 논문은 HVDC System의 컨버터를 구성하는 Thyristor 밸브의 스위칭동작을 테스트하는 합성시험회로의 기본동작을 분석한 내용에 대해 기술하고 있다. 합성시험회로(STC : Synthetic Test Circuit)는 HVDC System의 컨버터가 동작할 때 각 Thyristor 밸브에 나타나는 턴-온 전류와 턴-오프 전압을 인위적으로 공급하여 정상동작 여부를 시험할 수 있는 모의실험회로를 의미한다. 본 연구에서는 PSCAD 프로그램을 이용하여 2kV, 200A급 Thyristor를 테스트하기 위한 합성시험회로의 시뮬레이션 모형을 개발하고 그 동작을 분석하였다. 개발한 합성시험회로의 시뮬레이션 모델은 향후 IEEE와 IEC 규정에 만족하는 새로운 합성시험회로를 개발하는데 참고 자료로 활용 될 것으로 기대된다.

  • PDF

Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices (고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

Analysis of Insulation Characteristic for Small Hydro Generator (소수력발전기 절연특성분석)

  • Oh, Bong-Keun;Chang, Jeong-Ho;Lee, Kwang-Ho;Kang, Dong-Sik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.142-145
    • /
    • 2008
  • Electrical insulation of small hydro generator stator winding is one of the most important parts in generator facilities. Some stator winding insulation problems can be identified through analysis of insulation diagnostic test. So, Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of small hydro generator. This paper presents case studies of insulation failure in generator stator windings and the results of insulation diagnostic test for small hydro generator stator windings. Especially, Conducting the insulation diagnostic test before the generator installed in site is very important process to keep the good insulation condition in service.

  • PDF