• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.036 seconds

Position and Attitude Control System Design of Magnetic Suspension and Balance System for Wind Tunnel Test using Iterative Feedback Tuning and L1 Adaptive Control Scheme (IFT와 L1 적응제어기법을 이용한 풍동실험용 자기부상 비접촉식 밸런스의 제어시스템 설계)

  • Lee, Dong-Kyu
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.28-35
    • /
    • 2017
  • Magnetic Suspension and Balance System (MSBS) demonstrates the capacity to levitate an experimental model absent any mechanical contact using magnetic forces and moments. It allows precise control of position and attitude of the model, and measures external forces and moments acting on the model. For the purpose of acquisition of reliable experimental results under stable and safe conditions, the performance and robustness of the position and attitude control system of MSBS needs to be improved. To this end, Iterative Feedback Tuning (IFT) and L1 adaptive output feedback algorithm were employed to automatically increase command following performance and to ensure robust operation of MSBS with failure of electric power supply. The applicability was validated using computational simulation.

The Effect of Laser Acupuncture at $HT_7$(Sinmun) for Mental Stress on Short-term Analysis of Heart Rate Variability (신문혈(神門穴) 레이저침 시술이 정신적 스트레스를 가한 성인의 심박변이도에 미치는 영향)

  • Jang, Jin-Young;Cho, Seong-Yeun;Kim, So-Jung;Kim, Yong-Suk;Nam, Sang-Soo
    • Journal of Acupuncture Research
    • /
    • v.27 no.5
    • /
    • pp.51-58
    • /
    • 2010
  • Objectives : The purpose of this study is to assess the effect of laser acupuncture at $HT_7$ for reducing mental stress using power spectrum analysis of the heart rate variability. Methods : 36 healthy volunteers(control group: 18, treatment group: 18) participated in this study. After instrumentation and 5-minute rest period, 5-minute metal stress by operation was provided. HRV was recorded before and after the mental stress(1st, 2nd HRV). After 2nd HRV recording, the control group rested for 15 minutes without any treatments. Participants in the treatment group received laser acupuncture to $HT_7$ unilaterally and rested for 15minutes. Points were irradiated for 60seconds, and the intensity was 1.8J(output 20%). And then 3rd HRV was recorded. Results : In simple rest group, LF norm showed a significant change after mental stress. In laser acupuncture group, LF norm, HF norm, LF, HF and LF/HF ratio showed a significant change after mental stress. But there were no significant difference between two groups(ANCOVA test, p>0.05). In laser acupuncture group, LF norm, HF norm, HF and LF/HF ratio showed a significant change after laser acupuncture treatment. And there were significant differences between two groups(p<0.05). Conclusions : This study suggests that laser acupuncture at $HT_7$ can regulate and prevent the alternation of autonomic nervous system due to mental stress.

STABILITY OF MAXILLARY POSITION AFTER LEFORT I OSTEOTOMY USING BIODEGRADABLE PLATES AND SCREWS (생체흡수성 고정장치를 이용한 상악골 이동술 후 장기간 결과)

  • Kim, Bong-Chul;Jung, Young-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.499-503
    • /
    • 2007
  • Introduction: In orthognathic surgery, internal fixation has been usually done with titanium plates and screws. Recently, Biodegradable plates and screws have been frequently used but the reports of long term results of postoperative stability are rare, especially after maxillary reposition in orthognathic surgery. Objective: In order to clarify the clinical utility of self-reinforced bioresorbable poly-70L/30DL-Lactide miniplates & screws in maxillary fixation after LeFort I osteotomy, this study examined the postsurgical changes in maxilla and complications of biodegradable plates and screws. Study design: Nineteen patients who had undergone maxillary internal fixation using biodegradable plates and screws were evaluated radiographically and clinically. A comparison study of the changes in maxilla position after surgery in all 19 patients was performed with 1-week, 1-month, 3-months, 6-months and/or 1-year postoperative lateral cephalograms by tracing. Complication of the biodegradable plates and screws was evaluated by follow-up roentgenograms and clinical observation. And one-way ANOVA test was used for statistical analysis. Results: The position of the maxillary bone was stable after surgery and was not changed significantly from 1 week to 1 year after operation. And we could not find any complication of biodegradable plates and screws. Conclusions: Internal fixation of the maxilla after LeFort I osteotomy using self-reinforced biodegradable plates and screws is a reliable method for maintaining postoperative position of the maxilla after LeFort I osteotomy.

The effect of MedX exercise program on lumbar extensor strength in the elderly with chronic LBP (메덱스 척추강화운동 프로그램이 만성 요통 노인 환자들의 요부 신전 근력에 미치는 영향)

  • Cho, Hyun-Woo;Park, Sung-Kwang;Choi, Eun-Young;Kim, Myung-Joon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.33-43
    • /
    • 2004
  • The purpose of this study was to compare the lumbar extensor strength between before exercise and after 8 weeks exercise in the elderly. To evaluate lumbar extensor strength of total 18 patients (above 59 age) with low back pain or have experienced surgical operation. Lumbar extensor strength was measured in 8 male patients and 10 female patients (9 op group and 9 non-op group) by Medx lumbar extension machine. The data were analyzed with paired t-test compared to muscle strength, with repeated measured ANOVA compared to amount increase of muscle strength, using SPSS ver. 10.0 program. The results of this study were as follows: 1. There were significantly increased total lumbar extension strength was appear $6918.7{\pm}2802.77$ft-lbs in before exercise, $10432.83{\pm}2802.773397.1$ft-lbs in after 8 weeks exercise (p<. 05). 2. There were significantly increased total lumbar extension strength was increased to compared before exercise with after 8 weeks exercise in sex (p<. 05), op/non-op group (p<. 05).

  • PDF

Search Trend's Effects On Forecasting the Number of Outbound Passengers of the Incheon Airport (포탈의 검색 트렌드를 활용한 인천공항 출국자 수 예측 연구)

  • Shin, Euiseob;Yang, Dong-Heon;Sohn, Sei Chang;Huh, Moonhaeng;Baek, Seokchul
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.13-23
    • /
    • 2017
  • Short-term prediction of the number of passengers at the airport is very essential for the efficient and stable operation of the airport. Here, to forecast the immigration of Incheon International Airport, we perform the predictive modeling of Korean and Chinese outbound travelers comprising most of immigration. We conduct the Granger Causality test between the number of outbound travelers and related search trend data to confirm the correlation. It is found that the forecasting with both "outbound travelers" and "search term trends" data outperforms the one only with "outbound travelers" data. This is because search activities are done before doing something and this study confirms that search trend data inherently possess the potential for prediction.

Design and Performance Verification of Active Phased Array Antenna Near-Field Scanner with Mobility (이동성을 구비한 능동위상배열안테나 근접전계 스캐너 설계 및 성능 검증)

  • Yoo, Woo-Sung;Kim, Sung-Gyun;Kwon, Yong-Wook;Jung, Gi-Young;Jang, Heon-Soon
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.30-38
    • /
    • 2017
  • It is necessary to check the fault of phased array antenna, when the active phased array radar installed in the site is suspected performance degradation due to external impact or long-term operation. However, the near-field test should be performed in anechoic chamber in order to measure the phased array antenna, so that much time and cost must be applied for radar disassembly and transportation, and the operational availability of the radar system is deteriorates. Therefore, we propose a near-field scanner with mobility to check the fault of the phased array antenna at the site, and the effectiveness of the proposed scanner was verified with ${\pm}0.5dB$ magnitude and ${\pm}1.5^{\circ}$ phase in comparison with measured data in anechoic chamber.

Effect of Hydrogen Ratio and Tin Addition on the Coke Formation of Platinum Catalyst for Propane Dehydrogenation Reaction (프로판 탈수소화 반응용 백금촉매의 코크 생성에 미치는 수소비와 주석첨가의 영향)

  • Kim, Soo Young;Kim, Ga Hee;Koh, Hyoung Lim
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.82-88
    • /
    • 2016
  • The loss of activity by coke is an important cause of catalyst deactivation during industrial operation. In this study, hydrogen ratio of reaction condition, which has influenced on coke formation over Pt-Sn catalyst, and regeneration of catalysts activity by coke burning, Pt sintering of coke burning as coke contents, effects of coke formation and deactivation with different Sn contents were confirmed. Pt-Sn-K catalyst supported on θ-alumina and γ-alumina was prepared progressively. Activity of regenerated catalyst for propane dehydrogenation was compared with fresh catalyst by coke burning, after propane dehydrogenation was carried out with different hydrogen ratio at 620 ℃ on fresh catalyst. Regenerated catalyst’s physical characterization such as BET, coke analysis and XRD was investigated. Through catalytic activity test and characterization, Sn contents of catalyst and hydrogen ratio in feed stream could affect coke formation on catalyst surface. Excessive coke makes loss of activity and Pt sintering during air regeneration process.

A Prognosis Evaluation after Iliac Bone Graft in Cleft Alveolus Patients (치조열 환자의 장골이식술 후 예후 평가)

  • Hong Jin-Ho;Soh Byung-Soo;Baik Jin-Ah;Shin Hyo-Keun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.4 no.2
    • /
    • pp.69-78
    • /
    • 2001
  • Alveolar cleft exists in 75% of cleft patients, In alveolar cleft patients, alar base is widening, palatal fistular formation, maxillary growth disturbance & tooth loss of adjacent area is raised, Alveolar bone grafting, especially iliac bone grafting, is a general treatment method. As operation timing, bone grafting is classified with primary, early secondary, secondary, & late secondary, Here we report cleft width, marginal bone height, bone resorption rate, grafted shape & bone densities after secondary iliac bone grafting was done in the Dept. of oral and maxillofacial surgery of chonbuk national university hospital. We compared cleft width to bone resorption rate and grafted shape. Also, alveolar bone densities of grafted and contralateral site was compared with Emago 3 package? (Oral Diagonostic System, The Netherlands), The data obtained were analyzed using Spearman's rho coefficients and sign test with SPSS for window, The results were obtained as follows. 1. As alveolar cleft width is increase, bone resorption rate is, too. This relation showed significant difference(P<.01). 2, In proximal & distal area, alvolar cleft width and bone graft contour after bone grafting had a reverse proportional difference. It was not significant difference(P>.05). 3. After 3 month, in bone density results by using Emago 3 package? with periapical standard view, occlusal view & panoramic view, differences between grafted bone and alveolar bone of contralateral site didn't show a significant difference(P>.05). Thus, differences of bone densities in the alveolar bones didn't exist.

  • PDF

Study on the Off-design Performance on a Plug Nozzle with Variable Throat Area

  • Azuma, Nobuyuki;Tanatsugu, Nobuhiro;Sato, Tetsuya;Kobayashi, Hiroaki;Hongo, Motoyuki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.644-648
    • /
    • 2004
  • In the present study were examined numerically and experimentally the off-design performance characteristics on an axisymmetric plug nozzle with variable throat area. In this nozzle concept, its throat area can be changed by translating the plug into the axial direction. First, a mixed-expansion plug nozzle, in which two expansion parts are arranged both inside and outside, was designed by means of the method of characteristics. Second, the CFD analysis was verified by the cold-flow wind tunnel test. Third, its performance characteristics were evaluated over a wide range of pressure ratio from half to double throat area through the design point, using the CFD code verified by the wind tunnel tests. It was made clear from the study that not so critical thrust efficiency losses were found and the maximum thrust efficiency loss was at most approximately 5 % under off-design conditions without external flow. This result shows that a plug nozzle can give the altitude compensation even under off-design geometry operations. However, shock waves were observed in the inner expansion part under the doubled throat area operation and thus some thermal problems may be caused on the plug surface. Furthermore, collapse of cell structure on the plug surface was observed with external flow (around Mach number 2.0) as it became lower pressure ratio below the design point and the fact may result in big efficiency loss regardless of geometrical configuration.

  • PDF

Characteristics on Combustion Mode in Dual Mode Scramjet Engine (이중모드 스크램제트 엔진의 연소모드 특성)

  • Namkoung, HyuckJoon;Shim, ChangYeul;Kim, SunYong;Lee, MinSoo;Park, JooHyon;Kim, DongHwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.330-335
    • /
    • 2017
  • Recently many studies have been made for the development of propulsion system with wide range flight from supersonic to hypersonic. Dual Mode scramjet engine as a hybrid cycle with advantage of ramjet and scramjet has one combustor. It works under the ramjet mode (subsonic combustion) and scramjet mode (supersonic combustion) respectively. In this study, Experimental results of hot firing tests of dual scramjet engine designed on the condition of Mach 3.5~6 as a flight Mach number are discussed. The tests were carried out on a ground test bench under free stream condition of Mach 6 at 27.6km altitude. In the tests, the adopted design and technological solutions were verified and efficient operation of the dual mode ramjet engine with Kerosene combustion during 5 seconds was demonstrated.

  • PDF