• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.047 seconds

Application of discrete wavelet transform to prediction of ram stuck phenomena

  • Byun, Seung-Hyun;Cho, Byung-Hak;Shin, Chang-Hoon;Park, Joon-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1445-1449
    • /
    • 2005
  • The ram assembly is important equipment in fueling machine of PHWR(Pressurized Heavy Water Reactor) plant where fuel replacement is possible while the plant is in service. Troubles in the ram assembly can cause lots of difficulties in power plant operation. The ram assembly is typically composed of the B-ram, the L-Ram and the C-Ram. The B-ram is focused in this paper because it plays the most important role in the ram assembly. Among the ram fault phenomena, ram stuck phenomena are the most frequent cases in the B-ram, which has a ball screw mechanism driven by a hydraulic motor. Ram stuck phenomena are due to ball wear and damage in ball nut that increase in proportion to the number of fuel replacement. It is required to predict ram stuck phenomena before they occur. In this paper, a method is proposed for predicting ram stuck phenomena using a discrete wavelet transform. The discrete wavelet transform provides information on both the time and frequency characteristics of the input signals. The proposed method uses the frequency bandwidths of coefficients of discrete wavelet decompositions and detail coefficients of discrete wavelet transform to predict ram stuck phenomena. The signal used in this paper is a torque-related signal such as a hydraulic service outlet pressure signal in a hydraulic driving system or a current signal in a DC motor driving system. Finally, the validity of the proposed method is shown via experiment using ball nut characteristic test equipment that simulates ram stuck phenomena due to increased ball friction in ball nut.

  • PDF

CLINICAL STUDY OF FACIAL NERVE INJURY AFTER TMJ SURGERY (악관절 수술후 안면신경 손상에 대한 임상적 연구)

  • Kim, Hyung-Gon;Park, Kwang-Ho;Lee, Eui-Wung;Kim, Joon-Bae;Joo, Jae-Dong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.447-457
    • /
    • 1994
  • Authors have studied retrospectively the facial nerve injury after TMJ surgery through the preauricular approach routine. The study material used was 4 patients of all 113 patients who were diagnosed as internal derangement and have been operated from March 1989 to February 1991 in Youngdong severance hospital, and were induced postoperatived facial nerve injury. The patient group who had the postoperative injured facial nerve was recognized degree of injury using the diagnostic method, Electromyography(EMG) and Nerve conduction test(NCT) which are used widely at present and was treated as conservative care and we identified the recovery time as the same method. The results as follows : 1. The meticulous care and precious surgical technique are needed in both operation and postoperation. During the TMJ surgery, the excessive retraction of the flap and frequent use of nerve stimulator and electric surgical knife should be avoided as possible and postoperative hematoma and swelling should be minimized. 2. The 4 patients were experienced with the postoperative facial nerve injury of all 133 patients who had been operated the TMJ surgery through the routine preauricular approach on our hospital. And the incidence of postoperative facial nerve injury happened was about 0.3% and its incidence was relatively low comparing with any other previous reports. 3. EMG and NCT were considered as useful methods which can diagnose the nerve injury objectively and identified the effect of treatment and recovery time. 4. The faical nerve-injured patients who were induced postoperatively after TMJ surgery, were diagnosed as second-degree nere injury through the EMG and NCT. And the patient group was treated well as conservative physical therapy for about 2 to 4 months.

  • PDF

A CLINICAL STUDY ON THE PREOPERATIVE PSYCHOLOGICAL ASSESSMENT OF THE ORTHOGNATHIC SURGERY PATIENTS (안모변형증(顔貌變形症) 환자(患者)에 있어서 악교정(顎矯正) 수술전(手術前) 심리(心理) 평가(評價)에 관(關)한 임상적(臨床的) 연구(硏究))

  • Yang, Myeong-Cheol;Jin, Woo-Jeong;Shin, Hyo-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.1
    • /
    • pp.20-31
    • /
    • 1995
  • The need to assess preoperative psychological characteristics of orthognathic surgery patients has recently been recognized. Fifty six patients were involved in this study, they were investigated in the preoperative psychosocial aspects. Korean Version Eysenk Personality Questionaire and Korean Version Tennessee Self-Concept Scale were used for psychological test. The results were as follows : 1. There was no significant difference of sex and age in the personality dimension, the selfconcept scale, and the preoperative tests(P>0.05). 2. 37% of subjects showed phonetic problem, 60% masticatory problem and 56% social problem for facial deformity. The first choice was the face in the order of correction for mastication, phonation and face. And 83% of the subjects forecasted the change in their face after surgical correction, The answer was generally vague. 64% of the subjects expected their personality to become more lively as a result of their operation. 3. Total positive self score and personal self score were less improved in the groups with high scores of toughmindness and neuroticism(P<0.05), degree of suffering was increased in the group with high scores of neuroticism(P<0.05). 4. Degree of subjective deformity, self-consciousness, and degree of dissimilarity were more improved in the group of intraversion, there was a significant correlation with degree of dissimilarity in the group with high score of toughmindness(r=-.64, P<0.05). 5. There was a significant correlation with the forecast of change in the groups with high score in extraversion(r=.59, P<0.01) and with low score in neuroticism(r=-.39, P<0.05).

  • PDF

Use of piezoelectric surgery and Er:YAG laser:which one is more effective during impacted third molar surgery?

  • Keyhan, Seied Omid;Fallahi, Hamid Reza;Cheshmi, Behzad;Mokhtari, Sajad;Zandian, Dana;Yousefi, Parisa
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.29.1-29.10
    • /
    • 2019
  • Background: Reduction in postoperative complications is of vital considerations in impacted third molar teeth surgery. The aim of this study was to compare postoperative complications of impacted third molar surgeries for bone removal using laser, piezoelectric equipment, and conventional rotary instruments. Methods: To address the research purpose, the investigator designed the prospective double-blind clinical trial study. The sample size was determined 20 (40 teeth) by sampling formula in any kind of operation. The data of patients were obtained in the different periods in terms of pain, trismus, swelling, ecchymosis, and patient's satisfaction and then analyzed using SPSS 20 software via paired t test and Wilcoxon and McNemar's tests. Results: The pain immediately after surgery and 2 days and 7 days after surgery was higher in the laser group. The swelling immediately after surgery was more in the laser group but not significant. The amount of mouth opening immediately after surgery and 2 days and 7 days after surgery was significantly lower in the laser group than in the piezosurgery group. The total duration of surgery and duration of osteotomy were significantly longer in the laser group. The patient's satisfaction from surgery with piezosurgery was more than that with laser, but this difference was not significant. Conclusion: Due to the rising demand for impacted wisdom tooth surgery, the present study suggests that hard tissue laser surgery and piezosurgery can clear the future of impacted molar surgery, and these approaches are more efficient in reducing postoperative complications compared to the conventional surgeries.

An Assessment of Image Analysis of Longitudinal Bone Changes (시간경과에 따른 골변화의 영상 분석에 관한 연구)

  • Kim Young-Jin;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.73-86
    • /
    • 1997
  • This study was performed to assess the analyzing methods developed to detect clinically and quantitatively longitudinal bone changes. Through preliminary experiment, accuracy of Cu-Eq value conversion to the mass of HA was examined. For main experiment, 15 intraoral radiograms taken at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture in extracted sites of 3 cases were used. We took the radiograms with copper step wedge as test object and HA phantom X -ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner into computer were digitized and analyzed by NIH image program. The stability of the copper equivalent transformation and the usefulness of two analyzing methods by ROI and Reslice were examined. Obtained results as follows: 1) On the Cu equivalent images, the coefficient of variation in the measurement of Cu-Eq. value of ROI ranged from 0.05 to 0.24 and showed high reproducibility. 2) All results obtained by resliced contiguous image were coincident with those obtained from the assessment by ROI and formation of plot profile. 3) On the stacked and resliced image at the line of interest, we could analyze directly and quantitatively the longitudinal changes at several portions by plot profile and qualitatively by surface plot. 4) Implant area showed marked resorption till 2 weeks after implantation and showed significant increase in Cu-Eq. value at 6th week(p<0.01) and periapical area showed increase in Cu-Eq. value at 6th week compared to after-operation's.

  • PDF

Influencing factor on the prognosis of arthrocentesis

  • Kim, Yoon Ho;Jeong, Tae Min;Pang, Kang Mi;Song, Seung Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.4
    • /
    • pp.155-159
    • /
    • 2014
  • Objectives: The purpose of this article is to evaluate factors influencing prognosis of arthrocentesis in patients with temporomandibular joint (TMJ) disorder. Materials and Methods: The subjects included 145 patients treated with arthrocentesis at the Dental Center of Ajou University Hospital from 2011 to 2013 for the purpose of recovering mouth opening limitation (MOL) and pain relief. Prognosis of arthrocentesis was evaluated 1 month after the operation. Improvement on MOL was defined as an increase from below 30 mm (MOL ${\leq}30mm$) to above 40 mm (MOL ${\geq}40mm$), and pain relief was defined as when a group with TMJ pain with a visual analog scale (VAS) score of 4 or more (VAS ${\geq}4$) decreased to a score of 3 or more. The success of arthrocentesis was determined when either mouth opening improved or pain relief was fulfilled. To determine the factors influencing the success of arthrocentesis, the patients were classified by age, gender, diagnosis group (the anterior disc displacement without reduction group, the anterior disc displacement with reduction group, or other TMJ disorders group), time of onset and oral habits (clenching, bruxism) to investigate the correlations between these factors and prognosis. Results: One hundred twenty out of 145 patients who underwent arthrocentesis (83.4%) were found to be successful. Among the influencing factors mentioned above, age, diagnosis and time of onset had no statistically significant correlation with the success of arthrocentesis. However, a group of patients in their fifties showed a lower success rate (ANOVA P=0.053) and the success rate of the group with oral habits was 71% (Pearson's chi-square test P=0.035). Conclusion: From this study, we find that factors influencing the success of arthrocentesis include age and oral habits. We also conclude that arthrocentesis is effective in treating mouth opening symptoms and for pain relief.

Transient Calcification of Autogenous Grafted Patellar Tendon in Anterior Cruciate Ligament Reconstruction - A Case Report - (슬관절 전방 십자 인대 재건술 후 발생한 이식 건의 일과성 석회화 - 증례 보고 -)

  • Chung, Hyun Kee;Choi, Choong Hyeok;Kim, Jong Heon;Kim, Jae Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.30-34
    • /
    • 1999
  • We report the case of a 30-year-old man who was presented with transient calcification on the graft shortly after anterior cruciate ligament(ACL) reconstruction using a autogenous bone patellar tendon. The patient underwent ACL reconstruction with two incisional technique and six month later, calcific density was seen radiologically around the graft. On postoperative 13 months follow-up radiographic films, the calcific density disappeared. After two months of operation, Lachman and pivot shift test were negative and one millimeter side to side difference was detected in KT-1000 with 20 Ibs strength. But 6 months after the reconstruction, mild anterior instability was detected with the calcific density around the grafted tendon. However the anterior stability was recovered according to the disappearance of calcific density.

  • PDF

Design and Implementation on Frequency Synthesizer Qualification Model Level for SAR payload (위성 레이다용 QM급 주파수합성기 설계 및 제작)

  • Kim, Dongsik;Kim, Hyunchul;Heo, John;Kim, Wansik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.9-14
    • /
    • 2020
  • In this paper, Qualification Model of frequency synthesizer is designed for X-band SAR system and performed electrical and environment test. Designed frequency synthesizer generate 13.65 GHz with very low phase noise performance. The integrated phase noise from 10Hz to 1MHz is -37.91 dBc. IRF performances are analyzed according to phase noise and jitter. Also, thermal and structure analysis are achieved for stable operation in space environment. Designed frequency synthesizer is consist of 2 modules of 6U size and generate L-band, C-band, Ku-band. The result of this study would enhance the design ability of RF module and help the frequency synthesizer design for SAR payload system.

Study on the Design and Operation Characteristics of Ejector System (이젝터 시스템의 설계 및 작동 특성에 관한 연구)

  • NamKoung, Hyuck-Joon;Han, Poong-Gyoo;Kim, Young-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.627-630
    • /
    • 2009
  • Ejector system can induce the secondary flow or affect the secondary chamber pressure by both shear stress and pressure drop which are generated in the primary jet boundary. Ejectors are widely used in a range of applications such as a turbine-based combined-cycle propulsion system and a high altitude test facility for rocket engine, pressure recovery system, desalination plant and ejector ramjet etc. The primary interest of this study is to set up an configuration and operating conditions for an ejector in the condition of sonic and subsonic. Experimental and theoretical investigation on the sonic and subsonic ejectors with a converging-diverging diffuser was carried out. Numerical simulation was adopted for an optimal geometry design and satisfying the required performance. Also, some ejectors with a various of nozzle throat and mixing chamber diameter were manufactured precisely and tested for the comparison with the calculation results.

  • PDF

Hydrodynamic Analysis on Shock-induced Detonation in Pyrotechnic Initiator (파이로테크닉 착화기의 충격파 전달에 의한 폭굉 반응 해석)

  • Kim, Bohoon;Kang, Wonkyu;Jang, Seung-gyo;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.5
    • /
    • pp.19-30
    • /
    • 2016
  • We presented a hydrodynamic modeling necessary to accurately reproduce shock-induced detonation of pyrotechnic initiator. The methodology for such numerical prediction of shock propagation is quite straight forward if the models are properly implemented and solved in a well-formulated shock physics code. A series of SSGT(Small Scale Gap Test) and detailed hydrodynamic simulation are conducted to quantify the shock sensitivity of an acceptor that contains 97.5% RDX. A TBI(Through Bulkhead Initiator) system, consisting of a train configuration of Donor(HNS+HMX) - Bulkhead(STS) - Acceptor(RDX), were investigated to further validate the interaction between energetic and non-reactive materials for predicting the detonating response for successful operation of such small pyro device.