• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.04 seconds

A Study on Output Enhancement Method of PV Array Using Electrical Circuit Reconfiguration Algorithm (전기적 회로절체 알고리즘에 의한 태양광 어레이의 출력향상 방안에 관한 연구)

  • Kim, Byung-Mok;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.9-17
    • /
    • 2020
  • Recently, RES (renewable energy source) projects have been spreading all over the world as an alternative to solve the shortage of energy and environmental problems caused by fossil fuel consumption. The Korean government also supported the policy and demonstration project to increase the proportion of renewable energy to 63.8[GW] until 2030, which is 20[%] of the total power generation. On the other hand, output loss of a PV array can occur when the surrounding high-rise buildings and trees shade a PV array. Therefore, this paper proposes an algorithm to improve the output loss of a PV array, which electrically changes a circuit configuration of PV modules by wiring and switching devices. Furthermore, this study modeled a PV system based on PSIM S/W, which was composed of a PV array, a circuit configuration device, and a grid-connected inverter. From the simulations results with the modeling and test device, the existing method showed no output when 50% of the shade occurs in PV modules. In contrast, the proposed method could produce the output because the voltage in the PV module could be restored to 246[V], and the operation efficiency of the PV system could be improved by the operation algorithm of the circuit configuration device.

A study on the operation status and effective management of mixed-age classes in kindergartens (유치원 혼합연령학급 운영 실태 및 개선 방안에 관한 연구)

  • Lee, JinWha;Eom, Ji-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.253-261
    • /
    • 2016
  • This study discusses the effective management of mixed-ages classes in kindergarten. For the study, 300 kindergarten teachers in charge of mixed classes for regular courses completed a self-reported questionnaire through a web survey. The data were analyzed by chi-square test and presented by frequency and percentage. Mixed-ages classes had relatively fewer children than one-age classes and they were prevalent in public kindergartens and rural areas. The results were as follows. First, mixed-ages classes were induced by the small number of young children. Second, teachers managed their classes with difficulty due to the lack of supporting staff and few chances for additional teaching training. Third, teachers needed supporting human resources for their teaching and administration assistances. About 23.0% of kindergartens received assistance such as additional training, financial assistance, and consulting supervision from related institutions. The study results suggested the challenges in regulations of age ratio in mixed-ages class, additional teaching training for teachers in mixed-ages classes and replacement of mixed-ages class to same age class as the long-term plan.

An experimental study on the smoke-spread region before reaching the critical velocity for the case of fires in tunnels employing longitudinal ventilation system (종류식 환기 시스템에서 임계속도 도달 전 스모크 확산 영역에 관한 실험적 연구)

  • Ki, Young-Min;Yoon, Sung-Wook;Yoon, Chan-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.526-535
    • /
    • 2006
  • An experimental study was carried out on a reduced scale tunnel model to grasp the behavioral feature of fire-induced smoke in the long tunnels. Based on Froude modeling, the 1/50 scaled tunnel model (20 m long) was constructed by acrylic tubes and paraffin gas was released inside the tunnel to simulate the 20 MW fire-induced smoke. me test results show, that after approximately 2 minutes of fire generation, was descended from the tunnel ceiling through the decrease of buoyancy, then it was symmetrically propagated about 90 meters for 4 minutes before jet fans were operated. The smoke was effectively controlled when the jet fans were operated and an air stream velocity was getting closed to reach a critical velocity (the minimum air velocity that requires to suppress the smoke spreading against the longitudinal ventilation flow during the tunnel fire situations). It was also found out that a range of smoke was spreaded about 3 meters from the origin of fire but the range was not propagated to the escape direction anymore. The early stage of the In operation, however, showed that the smoke was hardly controlled. It means that the operation of emergency ventilation system has many dangerous factors such as an intercepting breathing zone.

Permeation Behavior of Olefin/Nitrogen Gases through Siloxane based Polymeric Membranes (실록산계 고분자 막을 통한 올레핀/질소 기체 투과 거동)

  • 이수복;신효진;최승학;김정훈;박인준;노재성;강득주
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.246-256
    • /
    • 2003
  • For the olefin recovery from polyolefin off-gas, the permeation behaviors of olefins and nitrogen were investigated through three kinds of PDMS membranes - cross-linked PDMS membranes, a polysiloxaneimide membrane, and oligo-PDMS modified PDMS membranes. Their pure gas permeabilities were measured as a function of operation temperature(-20 to $50^{\circ}C$) and pressure(1 to 25 atm) with ethylene($C_2\;H_4$), propylene($C_3\;H_6$), butylene($C_4\;H_8$), and nitrogen($N_2$) gases. The permeabilities of olefins and nitrogen highly depended upon the nature of PDMS membranes. Among these membranes, cross-linked PDMS membranes showed stable and high olefin/nitrogen selectivities over a wide operation pressure range and further study in various test conditions. Their permeability of olefin and nitrogen were governed by the condensation temperature(solubility selectivity) and plasticization, not the order of the size(diffusivity selectivity) of gases, which matched well with the general permeation behavior of rubbery polymeric membranes for condensable and non-condensable gases. With increasing feed pressure or decreasing feed temperature, the permeabilities of more condensible olefins increase highly, presumably due to high solubility and plasticization, but that of non-condensible nitrogen decreases slightly and thus, the selectivities of olefin/nitrogen increase highly.

Design of Vision Based Punching Machine having Serial Communication

  • Lee, Young-Choon;Lee, Seong-Cheol;Kim, Seong-Min
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2430-2434
    • /
    • 2005
  • Automatic FPC punching instrument for the improvement of working condition and cost saving is introduced in this paper. FPC(flexible printed circuit) is used to detect the contact position of K/B and button like a cellular phone. Depending on the quality of the printed ink and position of reference punching point to the FPC, the resistance and current are varied to the malfunctioning values. The size of reference punching point is 2mm and the above. Because the punching operation is done manually, the accuracy of the punching degree is varied with operator's condition. Recently, The punching accuracy has deteriorated severely to the 2mm punching reference hall so that assembly of the K/B has hardly done. To improve this manual punching operation to the FPC, automatic FPC punching system is introduced. Precise mechanical parts like a 5-step stepping motor and ball screw mechanism are designed and tested and low cost PC camera is used for the sake of cost down instead of using high quality vision systems for the FA. 3D Mechanical design tool(Pro/E) is used to manage the exact tolerance circumstances and avoid design failures. Simulation is performed to make the complete vision based punching machine before assembly, and this procedure led to the manufacturing cost saving. As the image processing algorithms, dilation, erosion, and threshold calculation is applied to obtain an exact center position from the FPC print marks. These image processing algorithms made the original images having various noises have clean binary pixels which is easy to calculate the center position of print marks. Moment and Least square method are used to calculate the center position of objects. In this development circumstance, Moment method was superior to the Least square one at the calculation of speed and against noise. Main control panel is programmed by Visual C++ and graphical Active X for the whole management of vision based automatic punching machine. Operating modes like manual, calibration, and automatic mode are added to the main control panel for the compensation of bad FPC print conditions and mechanical tolerance occurring in the case of punch and die reassembly. Test algorithms and programs showed good results to the designed automatic punching system and led to the increase of productivity and huge cost down to law material like FPC by avoiding bad quality.

  • PDF

Analysis of Performance on Activities in Critical Pathway of Total Hip Replacement Surgery (고관절 전치환술 환자의 임상관리도 수행 정도)

  • Lim, You Jin;Jeong, Kyung In;Jeong, Ha Yun;Sun, JeongJu;Kim, Yun Kyung;Choi, Ji Kyung;Lee, Kum Lae;Kim, Jeong Suk;Yang, Jin Ju;Kim, Hye Ja;Jang, Keum Seong;Choi, Ja Yun
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.5
    • /
    • pp.819-827
    • /
    • 2006
  • Purposes: The purpose of this study was to evaluate the extent of performance on activities in critical pathway (CP) according to eight domains and six admission days on nursing records of patients who received total hip replacement surgery. Methods: We reviewed 90 nursing records of patients who received total hip replacement surgery from June, 2004 to July, 2005 at C University Hospital. Data were collected using Hong's CP (2002) and were analyzed using ANOVA. Results: The domain of diet was valued the highest in CP performance scoring, followed by the domains of assessment, activities, and test. There were differences in the performance scores according to the period of admission in all of the domains. Among 132 activities in the CP, 18 activities were completely performed, of which most included activities belonging to the domain of assessment on the admission day. Twelve activities were never performed, of which most included activities belonging to the domain of treatment on the day of operation and the first day after operation. Conclusions: Therefore, further studies on the development of a new system to increase CP utilization and on updating the contents of CP from the best practice based on evidence is recommended.

  • PDF

Perfluorinated Sulfonic Acid based Composite Membranes for Vanadium Redox Flow Battery (바나듐 레독스 흐름 전지를 위한 과불소화 술폰산 복합막)

  • Cho, Kook-Jin;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.1
    • /
    • pp.21-27
    • /
    • 2016
  • Vanadium redox flow batteries (VRFBs) using the electrolytes containing various vanadium ions in sulfuric acid as supporting solution are one of the energy storage devices in alternatively charging and discharging operation modes. The positive electrolyte contains $V^{5+}/V^{4+}$ and the negative electrolyte $V^{2+}/V^{3+}$ depending on the operation mode. To prevent the mixing of two solutions, proton exchange membranes are mainly used in VRFBs. Nafion 117 could be the most promising candidate due to the strong oxidative property of $V^{5+}$ ion, but causes high crossover of electroactive species to result in a decrease in coulombic efficiency. In this study, the composite membranes using Nafion ionomer and porous polyethylene substrate were prepared to keep good chemical stability and to decrease the cost of membranes, and were compared to the properties and performance of the commercially available electrolyte membrane, Nafion 117. As a result, the water uptake and ionic conductivity of the composite membranes increased as the thickness of the composite membranes increased, but those of Nafion 117 slightly decreased. The permeability of vanadium ions for the composite membranes significantly decreased compared to that for Nafion 117. In a single cell test for the composite membranes, the voltage efficiency decreased and the coulombic efficiency increased, finally resulting in the similar energy efficiency. In conclusion, the less cost of the composite membranes by decreasing 6.4 wt.% of the amount of perfluorinated sulfonic acid polymer due to the introduction of porous substrate and lower vanadium ion permeability to decrease self-discharge were achieved than Nafion 117.

A Study on the Application of Spatial Big Data from Social Networking Service for the Operation of Activity-Based Traffic Model (활동기반 교통모형 분석자료 구축을 위한 소셜네트워크 공간빅데이터 활용방안 연구)

  • Kim, Seung-Hyun;Kim, Joo-Young;Lee, Seung-Jae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.4
    • /
    • pp.44-53
    • /
    • 2016
  • The era of Big Data has come and the importance of Big Data has been rapidly growing. The part of transportation, the Four-Step Travel Demand Model(FSTDM), a traditional Trip-Based Model(TBM) reaches its limit. In recent years, a traffic demand forecasting method using the Activity-Based Model(ABM) emerged as a new paradigm. Given that transportation means the spatial movement of people and goods in a certain period of time, transportation could be very closely associated with spatial data. So, I mined Spatial Big Data from SNS. After that, I analyzed the character of these data from SNS and test the reliability of the data through compared with the attributes of TBM. Finally, I built a database from SNS for the operation of ABM and manipulate an ABM simulator, then I consider the result. Through this research, I was successfully able to create a spatial database from SNS and I found possibilities to overcome technical limitations on using Spatial Big Data in the transportation planning process. Moreover, it was an opportunity to seek ways of further research development.

Change of Skin Temperature of Workers Using Vibrating Tools in Anthracite Mines (진동공구 사용근로자의 피부온도 변화)

  • Roh, Jae-Hoon;Moon, Young-Hahn;Shin, Dong-Chun;Cha, Bong-uk;Cho, Soo-Nam
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.357-364
    • /
    • 1988
  • By implementing epoch-making policies for industrial promotion, the national economy has made a remarkable development. As a result of such economic growth, industrial accidents and occupational diseases have become a serious problem in Korean society. In the presidential order for the execution of the Korean Labor Standard Law, neuritis and other diseases stemming from health impairments due to vibrations in industrial processes are designated to be dealt with as vibration diseases. In the case of vibration disease, industrial accident compensation is not effectively paid. In order to investigate the vibration hazards of rock-drill operation, the authors studied the subjective symptoms and performed physical function tests on a total of 79 persons (vibration exposed group) who used rock-drills, and 39 persons (control group) who did not use rock-drills at anthracite mines. The results of the physical function test were as follosws : 1. The right hand was more affected by white finger than the left hand. 2. Independent variables such as duration of rock-drill operation, age, drinking and smoking were indentified as statistically significant factors for the occurrence of white finger. 3. In the pain sense threshold, the group with Raynaud's phenomenon showed a statistically higher level than that of the control group. 4. The skin temperature of the group with Raynaud's phenomenon was lower than that of the control group. The recovery time of skin temperature aftr cooling was delayed compared with the value of the control group.

  • PDF

The Effect of Application of Injury Area to Overcrowding Indices in Local Emergency Department (지역응급의료센터에서 손상구역 운용이 응급실 과밀화 지표에 미치는 영향)

  • Kang, Jin Wook;Shin, Sang Do;Suh, Gil Joon;You, Eun Young;Song, Kyoung Jun
    • Journal of Trauma and Injury
    • /
    • v.20 no.2
    • /
    • pp.77-82
    • /
    • 2007
  • Purposes: There have been many efforts to improve the service of emergency centers. In spite of these, no evidence is showing any landmark advancement of emergency services, especially in the hospital stage, exists. We need some efficient standard criteria to evaluate emergency service in the hospital stage, and a useful method might utilize the overcrowding index. We want to know the change in the overcrowding index at a regional emergency center after injury area administration. Injury area means an area in which only an assigned duty physician manages patients with injuries such as those from traffic accidents, falls, assualts, collisions, lacerations, amputations, bums, intoxication, asphyxia, drowning, animal bites, sexual assualts, etc. Methods: We started to operate an injury area in our emergency department from late 2004, and from January to June in 2004 and in 2005, we collected patients' data, age, sex, assigned department, and result from hospital order communication system to figure out overcrowding indices and result indices. We found the daily number of patients, the turnover rate, the admission rate, the ICU admission rate, the emergency operation rate, the ED stay duration, and the ED patient volume to be overcrowding indices. Also we found the withdrawal rate, the transfer rate, and mortality to be result indices. We compared these indices between 2004 to 2005 by using a t-test. Results: There was a significant increase in the daily number of visiting patients in 2005, overcrowding indices, such as the turnover rate, the admission rate, the ICU admission rate, and the emergency operation rate, also showed statistically significant increases in 2005 (P<0.001). As for the result indices, there was a noticeable decrease in the number of withdrawals (11.77/day in 2004 to 4.53/day in 2005). Conclusion: Operating an injury area in a mildly overcrowded local emergency center is beneficial. Evaluating the effect of operating an injury area and it's impact on hospital finances by conducting a similar study analyziing patients for a longer duration would be valuable.