• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.035 seconds

A Design of New Real Time Monitoring Embedded Controller using Boundary Scan Architecture (경계 주사 구조를 이용한 새로운 실시간 모니터링 실장 제어기 설계)

  • 박세현
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.6
    • /
    • pp.570-578
    • /
    • 2001
  • Boundary scan architecture test methodology was introduced to facilitate the testing of complex printed circuit board. The boundary scan architecture has a tremendous potential for real time monitoring of the operational status of a system without interference of normal system operation. In this paper, a new type of embedded controller for real time monitoring of the operational status of a system is proposed and designed by using boundary scan architecture. The proposed real time monitoring embedded controller consists of test access port controller and an embedded controller proposed real time monitoring embedded controller using boundary scan architecture can save the hard-wire resource and can easily interface with boundary scan architecture chip. Experimental results show that the real time monitoring using proposed embedded controller is more effective then the real time monitoring using host computer.

  • PDF

Internal Blast Tests of Developed Explosives (개발 화약의 내폭풍압 측정)

  • Kim Sung-ho;Kim Jeong-kook;Lee Jun-wung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.3 s.18
    • /
    • pp.122-128
    • /
    • 2004
  • Internal blast performance test on developed explosives was carried out. Internal blast means a blast wave in closed chambers like tunnels, bunkers, operation center and chamber of ships. We used Anpa tunnel for our test facility. We performed two series of tests to measure internal blast of developed explosives. Three different kinds of cast PBXs, DXD-09, DXD-10, DXD-18, and conventional explosive, Tritonal, were used in our test. The explosives were cast as a charge of 108mm diameter in a plastic tube of a 3mm thickness. The length of charges 4ere adjusted as a weight 3kg. A melt-cast explosive, tritonal, was used as a reference. Pentolite booster was used. The cylindrical boosters have a 95mm diameter and 47.5mm height. The results showed that there may be some differences between the performances in the air blast tests and those in the internal blast tests. The results showed that DXD-10, the best performance in air blast tests, showed the poorest performance in internal blast among the explosives tested. On the other hand, DXD-18 showed exactly the opposite trend. This is probably due to the highest contents of aluminum and inert binder in DXD-18. DXD-18 has $38\;wt\;\%$ of aluminum and $17\;wt\;\%$ of inert binders.

Wind Tunnel Test for the Inflation Characteristics of the Korean Low Cost Low Altitude Aerial Delivery System (한국형 저비용 저고도 공중보급 체계용 낙하산 전개 특성 풍동시험)

  • Kim, Seung Pil;Jung, Insik;Kwon, Kybeom;Choi, Younseok;Chung, Hyoungseog
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.345-351
    • /
    • 2017
  • A wind tunnel test for the scaled parachute models was performed to verify aerodynamic characteristics for practical usage of Korean low cost low altitude aerial delivery system. The cruciform shaped cargo parachute models for heavy and light weight were ejected into wind tunnel test section; and the drag forces acting on the models in steady condition were measured in accordance with velocity. Also, the maximum opening forces during inflation were obtained and captured by a high speed camera to analyze the inflation characteristics and evaluate the design of the low cost aerial delivery system. The results showed a reliable stability and met the design requirement of delivery operation system for R.O.K Air Force.

An Experimental Study on the Removal Characteristics of Indoor Air Pollutants using an Air Cleaning System (실내 공기정화 시스템에 의한 실내 오염입자의 제거특성에 관한 실험적 연구)

  • 김성찬;이창건;안영철;이재근;강태욱;이감규;구정환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.733-737
    • /
    • 2003
  • The purpose of this study is to analyze the particle removal characteristics of a commercial air cleaner based on the electrostatic precipitator. The air cleaner consists of a positive corona precharger to precharge particles and a collector to remove the charged particles. The test for particle removal efficiency is conducted with tobacco smoke particles of 1.27${\mu}{\textrm}{m}$ in mass median diameter. The result of one-pass filtration test shows that the filtration efficiency is more than 90% for the particles larger than 2.5 Um, while the efficiency for the particles of 0.5~1.0${\mu}{\textrm}{m}$ in case of 4.18 CMM is 70%. For the test room of 5,800${\times}$3,400${\times}$2,600㎣, the concentration of tobacco smoke particles decreases up to 30% of initial values within 30 minutes due to natural reduction and up to 90% of initial values within 30 minutes with the air cleaner operation.

Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process (원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법)

  • Son, Bong-Ho;Lim, Bong-Su;Oa, Seong-Wook;Lee, Byung-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

Generating Method of the Input Profile in the MAST System (자동치부품(시트, 도어) 6축 진동 재현을 위한 가진 프로파일 생성 기법)

  • Lee, Bong-hyun;Kim, Gi-Hoon;Kim, Chan-jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1070-1076
    • /
    • 2005
  • Vibration test using the MAST(multi axial simulation table) provide a more reliable testing environment than any conventional one. The multi axial simulation could be possible with a advanced control algorithm and hardware supports so that most of the operation is automatically conducted by MAST system itself except the input information that is synthesized by the measured response signals. That means the reliability of the vibration test is highly depended on the quality of the input profile. In this paper, the optimal algorithm based on the energy method is introduced to construct a best combination of candidated input PSD data could be constructed. Since the optimal algorithm renders time information, the nitration fatigue test is completely possible for any measured signals one wants. The proposed method is explained with representing acquired road signals from the candidate input PSD obtained from a proving ground.

Buckling and Vibration Characteristics of the Capsule for Nuclear Fuel Irradiation Test (핵연료 조사시험용 캡슐 구조물의 좌굴 및 진동특성)

  • 강영환;김봉구;류정수;김영진;최명환
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.8
    • /
    • pp.741-748
    • /
    • 2004
  • The vibration and buckling characteristics of the capsule for fuel irradiation test are studied. The natural frequencies of the capsule in air and under water are obtained by modal testing and finite element (FE) analysis using ANSYS program, and accelerations with flow are measured to estimate the compatibility with the operation requirement of the HANARO reactor. The experimental fundamental frequencies of the capsule in the x and z direction are 8.5 Hz and 8.75 Hz in air, and 7.5 Hz and 7.75 Hz under water, respectively. The maximum amplitude of accelerations under the normal operating condition is measured as 11.0 m/s$^2$ that is within the allowable vibrational limit(18.99 m/s$^2$) of the reactor structure. Also, the maximum displacement at 100% flow is calculated as 0.13 mm which is not interference with other nearby structures. FE analysis results show that the natural frequencies are found to be similar to those of the modal testing when three supporting parts are considered as simply supported conditions. From the buckling analysis, when the loading tool is applied, the critical buckling load of the capsule is 233 N.

Development of an Examination System for a e-Learning Quality Manager's Certificate (이러닝 품질관리사의 자격 검정 체제 개발)

  • Ryu, Jin-Sun;Moon, Dae-Young;Lee, Kyung-Soon;Kim, Hee-Pil
    • Journal of Engineering Education Research
    • /
    • v.16 no.1
    • /
    • pp.35-44
    • /
    • 2013
  • The purpose of this study is to develop an examination system for an e-learning quality manager's certificate which is composed of subjects, criteria, method of examination. The task model of e-learning quality manager was modify and task/knowledge/skill matrix was developed to design the examination system through conferences of DACUM committee and an advisory committee. And a survey was carry out to analyze validity of contents of the examination system. The major findings were as the follow: First, occupational specification, job specification, task specification and task/knowledge/skill matrix were developed. Second, examination subjects were developed based on task/knowledge/skill matrix, which were "Basis of e-Learning and plan of service", "Expulsion and management of e-learning infrastructure", "Development of e-learning contents", "Operation and evaluation of e-learning service". Third, the criteria and methods of examination for an e-learning quality manager's certificate were developed, which is composed of test type, the sum of test items, test time and acceptable standards.

Estimation of vertical and horizontal spreading force of the towing cage for transporting the live fish by model test and simulation (모형실험과 시뮬레이션을 통한 활어 이송용 예인 가두리의 수직 및 수평 전개력 추정)

  • Park, Subong;Lee, Chun Woo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.2
    • /
    • pp.176-184
    • /
    • 2014
  • Nowadays, consumption of fisheries products is increasing. There are several factors, one of which is a quantitative development through aquaculture. Another factor is an increase qualitative consumption of fish which require that fish be supplied alive. This requires a lot of technical effort to transport the live fish that have low survival rate (c.f. tuna and mackerel) in coastal waters and in the open sea. To develop a towing cage for transporting the live fish, model test in a circulate water channel and simulation by computer tool were carried out. In order to spread vertically, floats were attached at the upper part of the cage, and iron chains attached at the lower part of the cage. For horizontal spreading, kites were attached on the cage. The tension and spreading performance of the cage were measured. The result shows that the tension and reduction ratio of inside volume of the cage were tended to increase with increased towing speeds. The suitable operation condition in towing cage was 1.0 m/s towing speeds with vertical spreading force 8.7 kN, horizontal spreading force 5.6 kN; in this case the reduction ratio of inside volume of the cage was estimated as 25%.

A Study on the Radiated Noise from Power Line during EFT Immunity Test (EFT(Electrical Fast Transient)내성 시험시 발생되는 전원선 복사 잡음에 관한 연구)

  • 정삼영;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.234-241
    • /
    • 2000
  • During the EFT immunity test, the fast transient voltage is injected to the power or signal line. The radiated noise from these lines influences the near-by EUT, and consequently, the reliability of the test result can be jeopardized. The measured data of the field strength and wave shape of the noise were compared with the result of the mathematical analysis using transmission line model. When the tests were performed by the conditions the same as stated in IEC 61000-4-4, the results showed that the magnitude of the radiated electric field strength was about 2.4KV/m, and it can cause severe interference to the intended operation of EUT.

  • PDF