• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.034 seconds

Development of Transient Simulation Program for Smart UAV Propulsion System (스마트 무인기 추진기관의 천이 모사 프로그램 개발)

  • Lee, Chang-Ho;Ki, Ja-Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.63-69
    • /
    • 2011
  • The Smart UAV must have the control characteristics of propulsion system necessary for both rotary aircraft and fixed wing aircraft though it equips turbo-shaft engine. To develop an electronic engine controller in the future, it is necessary to accumulate the experience of engine operation and data of tilt rotor aircraft. For this purpose, the computer programs which predict engine performance in the steady state and transient state can be utilized for the supplementation of flight test data. In this work, we developed a dynamic analysis program using engine performance data gathered during the flight tests. In addition the accuracy of the program was verified through comparison with flight test data and the results of steady-state performance analysis program.

A Study on the Evaluation Method of ACC Test Using Monocular Camera (단안카메라를 활용한 ACC 시험평가 방법에 관한 연구)

  • Kim, Bong-Ju;Lee, Seon-Bong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.3
    • /
    • pp.43-51
    • /
    • 2020
  • Currently, the second level of the six stages of self-driving technology, as defined by SAE, is commercialized, and the third level is preparing for commercialization. The purpose of ACC is to be evaluated as a system useful for preventing and preventing accidents by minimizing driver fatigue through longitudinal speed control and relative distance control of the vehicle. In this regard, for the study of safety assessment methods in the practical environment of ACC. Distance measurement method using monocular camera and data acquisition equipment such as DGPS are utilized. Based on the evaluation scenario considering the domestic road environment proposed by the preceding study, the relative distance obtained from equipment such as DPGS and the relative distance using a monocular camera in the actual test is verified by comparing and analyzing the safety assessment. The comparison by scenario results showed a minimum error rate of 3.83% in Scenario 1 and a maximum of 14.61% in Scenario 6. The cause of the maximum error is that the lane recognition is not accurate in the camera image and irregular operation conditions such as rushing in or exiting the surrounding area from the walkway. It is expected that safety evaluation using a monocular camera will be possible for other ADAS systems in the future.

The Design of a Small GNSS Receiver with Enhanced Interference Suppression Capability for High Mobility

  • Park, Yong-Hyun;Moon, Sung-Wook;Shin, Bong-Gyu;Oh, Jong-Su
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • The applications of Global Navigation Satellite System (GNSS) receivers are becoming wider in various commercial and military systems including even small weapon systems such as artillery shells. The precision-guided munitions such as Small Diameter Bomb (SDB) of United States can be used for pinpoint strike by acquiring and tracking GNSS signals in high mobility situation. In this paper, a small GNSS receiver with embedded interference suppression capability working under high dynamic stress is developed which is applicable to the various weapon systems and can be used in other several harsh environments. It applies a kind of matched filter and multiple correlator schemes for fast signal acquisition and tracking of even weak signals and frequency domain signal processing method to eliminate the narrowband interference. To evaluate the performance of the developed GNSS receiver, the test scenario of high mobility and interference environment with the GNSS simulator and signal generator is devised. Then, the signal acquisition time, navigation accuracy, sensitivity, and interference suppression performances under high dynamic operation are evaluated. And the comparison test with the commercial GNSS receiver which has high sensitivity is made under the same test condition.

Vibration Analysis and Reduction of a SMT Mounter Equipment (SMT 마운터 장비의 진동 분석 및 저감)

  • Rim, Kyung-Hwa;An, Chae-Hun;Yang, Xun;Han, Wan-Hee;Beom, Hee-Rak
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.53-58
    • /
    • 2009
  • A SMT mounter is a kind of equipment that mounts SMD parts quickly on the printed circuit board. By using linear motors, it is controlled with high speed and precision, which is similar to semi-conductor and display process equipment. It is necessarily used in an assembly process of an electronic device. Mobile devices such as a mobile phone and PDA are required to reduce mount areas due to the demands for high performance and small size. Hence, super small sized and complex mobile devices have been developed. To improve the productivity of the corresponding equipment, designs with large sized, high speed, and multidisciplinary functions have been consistently performed. Meanwhile, a design trend of large size and light-weight on SMT mounter causes a low natural frequency of systems and vibration problems at the high speed operation. In this paper, the dynamic characteristics of the SMD mounter system were investigated through a modal test and transmissibility test, and verified by finite element method. Also, various design improvement was performed to avoid the resonance phenomena.

  • PDF

Lifetime Assessment Criteria and Failure Analysis for the Clutch Coil in an Automotive Air Conditioner (자동차용 에어컨 클러치 코일의 수명평가 기준과 고장해석)

  • Choi, Man-Yeop;Wei, Shin-Hwan;Kim, Jung-Sik;Jeong, Hai-Sung
    • Journal of Applied Reliability
    • /
    • v.11 no.2
    • /
    • pp.111-126
    • /
    • 2011
  • The clutch coil mounted on the automotive air conditioner is an important part which actuates the clutch to connect or disconnect the pulley and the compressor according to the climate control condition in an automobile. Here, it is generally required that the clutch coil should ensure the long term durability requirement, such as a warranty for the 10 years of field operation or 160,000 km driving, especially in a brand new item, and so forth. However, some difficulties have arisen in restoring its credibility, since domestic specifications for the part have not been yet unified. In order to ensure the reliability, test methods and assessment criteria should be standardized. Moreover, assessed lifetime under specific conditions and potential failure analysis would be important. In this study, lifetime test specifications for the clutch coil have been reviewed and methodological suggestions are provided to ensure reliability, utilizing a quality function deployment through the potential failure mode effect analysis.

Buckling and Vibration Characteristics of the Capsule for Nuclear Fuel Irradiation Test (핵연료 조사시험용 캡슐 구조물의 좌굴 및 진동특성)

  • 강영환;김봉구;류정수;김영진;최명환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.125-130
    • /
    • 2004
  • The vibration and buckling characteristics of the capsule for fuel irradiation test are studied. The natural frequencies of the capsule in air and under water are obtained by modal testing and finite element(FE) analysis using ANSYS program, and accelerations with flow are measured to estimate the compatibility with the operation requirement of the HANARO reactor. The experimental fundamental frequency of the capsule in the x and z direction is 8.5Hz and 8.75Hz in air, and 7.5Hz and 7.75Hz under water, respectively. The maximum amplitude of accelerations under the normal operating condition is measured as 11.0m/s$^2$ that is within the allowable vibrational limit(18.99m/s$^2$) of the reactor structure. Also, the maximum displacement at 100% flow is calculated as 0.13mm which is not interference with other nearby structures. FE analysis results show that the natural frequencies are found to be similar to those of the modal testing when three supporting parts are considered as simply supported conditions. From the buckling analysis, when the loading tool is applied, the critical buckling load of the capsule is 233N.

  • PDF

The Effect of Music Therapy on Anxiety and Vital Signs of Spinal Anesthesia Operative Patients (음악요법이 척추마취수술환자의 상태불안과 활력징후에 미치는 효과)

  • Lee, Ji-Min;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.10 no.2
    • /
    • pp.113-120
    • /
    • 2008
  • Purpose: The aim of this study is to evaluate the effect of music therapy according to preferred music and to identify the effect of duration time and starting point of music therapy on anxiety and vital signs in spinal anesthesia operations. Method: These subjects were categorized into three groups based on the order of the date of operation. Data on anxiety and vital signs for this study were collected from them. The collected data were analyzed by $X^2$-test, t-test, paired t-test and ANCOVA. Result: The results of this study showed that preferred music, differences of duration times and starting points of music therapy didn't make significant differences in anxiety and vital signs among the three groups. However for anxiety, there was a meaningful difference within three groups. This result indicates even randomly chosen music by nurses considering the patients' age makes a meaningful difference in anxiety. Conclusion: Based on the results of this study, the conclusion can be made that music therapy is a useful nursing implementation to reduce anxiety in patients undergoing operations with spinal anesthesia.

  • PDF

The Design and Hot-firing Tests of a regenerative-cooled Sub-scale Combustor (재생냉각 축소형 연소기의 설계 및 연소시험)

  • Lee, Kwang-Jin;Kim, Jong-Gyu;Lim, Byoung-Jik;Kim, Hong-Jip;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2007
  • It was carried out hot-firing test with a regenerative-cooled sub-scale combustor which was applied regenerative-cooling, film cooling and thermal barrier coating. Test results showed that cooling methods used in the combustor play an full role in the operation of the combustor under the design condition but it is occurred high frequency combustion instability due to unsteady flow of fuel by structural support ring inserted in fuel manifold. The flow pattern of fuel was improved by excluding the ring and it will be carried out additional hot-firing test to verify the combustion stability of modified combustor.

  • PDF

Life Prediction and Evaluation of Fracture Toughness of a Cr-Mo Degraded Steel During Long Service (장기 사용 Cr-Mo강 열화재의 파괴 인성 평가와 수명예측)

  • 권재도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1421-1428
    • /
    • 1992
  • It has been increasingly recognized that the safety analysis considering fracture mechanics is required of the pressure vessels made of 2 1/4 Cr-1Mo steel for safe operation due to temper-embrittlement during long term service. In this study, the fracture toughnesses of degraded and recovered 2 1/4 Cr-1Mo steels have been studied with J$_{IC}$ test specimens at room temperature and the results will be compared with the data obtained from the Charpy impact test. The fracture toughness data from above experiments will be applied to life prediction based on the surface crack growth for degraded and recovered Cr-Mo pressure vessels.

Shunt-Responsive Idiopathic Normal Pressure Hydrocephalus Patient with Delayed Improvement after Tap Test

  • Kang, Kyunghun;Hwang, Sung Kyoo;Lee, Ho-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.437-440
    • /
    • 2013
  • The cerebrospinal fluid tap test (CSFTT) is recommended as a key step in the diagnosis of idiopathic normal pressure hydrocephalus (iNPH). While there is no generally accepted evaluation period for ascertaining a CSFTT responder, a substantial number of patients are evaluated only once within 24 hours of the test for improvement in gait. We report an iNPH patient with a favorable response to shunt surgery, who was first judged a non-responder by this standard, though subsequently was judged a responder in virtue of repetitively testing gait over 7 days. A 68-year-old man presented with progressive impairment of gait, balance, and memory. He was diagnosed as iNPH with an Evans' ratio of 0.35. At first hospitalization, change in gait was evaluated 24 hours after the CSFTT. He didn't show any significant improvement and was judged as a non-responder. However, at the second CSFTT, we repetitively tested his change in gait over seven days. Forty-eight hours after the tap, he showed significant improvement in his gait. He was then confirmed as a responder. After the operation, the gait difficulties were almost fully resolved. Further studies developing the standard procedure of the CSFTT should be considered.