• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.034 seconds

Effect of Aging Time on Creep Property of Cast Haynes 282 Superalloy (초내열합금 Haynes 282 주조합금의 크리프강도에 미치는 시효처리의 영향)

  • Kim, Young-Ju;Ahn, Yong-Sik
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.13-20
    • /
    • 2017
  • Ni-base superalloy Haynes 282 was developed as a gas turbine material for use in the ultra-super-critical stage (USC) of next-generation coal-fired power plants. Temperatures in the USC stage exceed $700^{\circ}C$ during operation. In spite of its important role Haynes 282 in increasing the performance of high-pressure turbines, as a result of its high-temperature capability, there is little information on the microstructure, deformation mechanism, or mechanical properties of the cast condition of this alloy. The aim of present study is to examine the creep properties of cast alloy and compare with wrought alloy. The ${\gamma}^{\prime}-precipitates$ were coarsen with the increase of aging time ranging from 8 to 48 hrs. A creep test performed at $750^{\circ}C$ showed faster minimum creep rate and shorter rupture lifetime with the aging time. A creep test performed showed only a slight difference in the rupture life between cast and wrought products. Based on the creep test results, the deformation mechanism is discussed using fractographs.

Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring (조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

A Study of Threshold Determination of The GPS measurement failure using GPS Code-Carrier Divergence Test (GPS 의사거리-반송파 위상 측정치의 고장검출을 위한 임계값 결정 연구)

  • Son, Eunseong;Kim, Koon-Tack;Im, Sung-Hyuck;Lee, Eun-Sung;Heo, Moon Beom;Nam, Gi-Wook
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.1
    • /
    • pp.10-15
    • /
    • 2016
  • In this study, The code-carrier divergence test was applied to GPS measurements, and the results were compared and analyzed. The GPS data used for the threshold determination were obtained from Global Navigation Satellite System permanent stations built by the Korea Aerospace Research Institute. At each permanent station, identical dual-frequency receiver and choke ring antenna with radome are installed. The analysis method, root mean square values were compared and analyzed for each permanent station and satellite. As a result, the root mean square value generally decreased as the satellite elevation angle increased although the trend was gentle. Threshold were finally selected based on the average and standard deviation of root mean square for each permanent station. For improving of availability and continuity in real-time operation when the threshold is over the limits, Code-Carrier divergence test values are initialized.

Cleaning Model of Head-feeding Combine (자탈형 콤바인의 선별모델)

  • Kim, S.H.;Kang, W.S.;Gregory, James M.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.1
    • /
    • pp.22-32
    • /
    • 1994
  • The combine harvester is considered as an important but complicated and costly machine. The appropriate size of combine has to be developed to use efficiently in Korea. But the combine is such a complicated machine that a complete design model to develop a new type is impossible without understanding the relationship between each factor. The combine capacity is generally limited by the cleaning shoe performance. So a design model for a cleaning shoe has to be developed first for the complete combine design. The objective of this research was to develop a cleaning model of head-feeding combine to predict grain separation from chaff and broken straw on a sieve. A developed physically based model can explain the situation which can happen during separation process. A test apparatus based on the field going machine was developed. The test materials were paddy rice and barley. The data obtained were analyzed by the hand and the video camera. The developed model was verified as an adequate model through the test with $R^2$ of 0.934 and 0.837. The model can be used to evaluate design and operation alternatives of combine and also applied to the automatic control of separation unit of combine with a loss monitering sensors.

  • PDF

Auxiliary Power Unit Emergency Fuel Test (보조동력장치 비상연료 시험)

  • Lim, Byeung-Jun;Lee, Dong-Ho;Koo, Hyun-Cheol;Ryu, Se-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.908-911
    • /
    • 2011
  • Aircraft Auxiliary Power Unit can start and operate using not only main fuel(JP-8) but also specified emergency fuels for emergency operation. In oder to verify emergency fuel requirement, emergency fuel test using commercial diesel fuel was performed. Changes in specific fuel consumption due to use of diesel fuel are 3.5%~7.8%, which satisfied requirement. Diesel fuel showed similar starting characteristic to the JP-8. The specific fuel consumption of diesel increased by 2.0%~3.4% compared with that of JP-8.

  • PDF

Implementation of an Integrated Monitoring System for Constructional Structures Based on SaaS in Traditional Towns with Local Heritage (SaaS(Software as a Service) 기반 지방유적도시 구조물 유지관리계측 통합모니터링시스템 구현)

  • Min, Byung-Won;Oh, Yong-Sun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.15-16
    • /
    • 2015
  • Measuring sensor, equipment, ICT facilities and their software have relatively short life time comparing to constructional structure so that we should exchange or fix them continuously in the process of maintenance and management. In this paper, we propose a novel design of integrated maintenance, management, and measuring monitoring system applying the concept of mobile cloud. For the sake of disaster prevention for constructional structures such as bridge, tunnel, and other traditional buildings in the village of local heritage, we analyze status of these structures in the long term or short term period as well as disaster situations. Collecting data based on mobile cloud and analyzing future expectations based on probabilistic and statistical techniques, we implement our integrated monitoring system for constructional structures to solve these existing problems. Final results of this design and implementation are basically applied to the monitoring system for more than 10,000 structures spread over national land in Korea. In addition, we can specifically apply the monitoring system presented here to a bridge of timber structure in Asan Oeam Village and a traditional house in Andong Hahoe Village to watch them from possible disasters. Total procedure of system design and implementation as well as development of the platform LinkSaaS and application services of monitoring functions implemented on the platform. We prove a good performance of our system by fulfilling TTA authentication test, web accommodation test, and operation test using real measuring data.

  • PDF

Development of Polymetallic Nodules in the NE Equatorial Pacific: Past, Present and Future (심해저 망간단괴 개발의 현황과 미래)

  • Chi, Sang Bum;Hong, Sup
    • Ocean and Polar Research
    • /
    • v.36 no.4
    • /
    • pp.367-371
    • /
    • 2014
  • In early 1990s, the Korean government has launched a deep-sea research program to secure the stable long-term supply of strategic metallic minerals including Cr, Cu and Ni. Through the pioneering surveys, Korea registered $150,000km^2$ of Mn-nodule field in the Clarion-Clipperton area, the NE equatorial Pacific to the international sea-bed authority (ISA) in 1994. Following the ISA exploration code, the final exclusive exploration area of $75,000km^2$ was assigned in 2002, based on results of eight-year researches of chemico-physical properties of nodules, bottom profiles and sediment properties. Since that time, environmental studies, mining technical developments including robot miner and lifting system and establishment of smelting systems were accompanied with the detailed geophysical studies to decipher the priori mining area until 2009. Major points of the recent Korea Mn-nodule program are deployed on a commercial scale until 2015. In order to meet the goals, we developed a 1/5 scaled robot miner compared to commercial one in 2012 and performed a mining test at the water depth of 1,370 m in 2013. In addition, detailed 25,000 scaled mining maps in the priori area, which can provide operation roots of the miner, will be prepared and an environmental-friendly mining strategy will be pursued based on the environmental impact test and environmental monitoring.

A Construction Method for Personalized e-Learning System Using Dynamic Estimations of Item Parameters and Examinees' Abilities

  • Oh, Yong-Sun
    • International Journal of Contents
    • /
    • v.4 no.2
    • /
    • pp.19-23
    • /
    • 2008
  • This paper presents a novel method to construct a personalized e-Learning system based on dynamic estimations of item parameters and learners' abilities, where the learning content objects are of the same intrinsic quality or homogeneously distributed and the estimations are carried out using IRT(Item Response Theory). The system dynamically connects the test and the corresponding learning procedures. Test results are directly applied to estimate examinee's ability and are used to modify the item parameters and the difficulties of learning content objects during the learning procedure is being operated. We define the learning unit 'Node' as an amount of learning objects operated so that new parameters can be re-estimated. There are various content objects in a Node and the parameters estimated at the end of current Node are directly applied to the next Node. We offer the most appropriate learning Node for a person's ability throughout the estimation processes of IRT. As a result, this scheme improves learning efficiency in web-base e-Learning environments offering the most appropriate learning objects and items to the individual students according to their estimated abilities. This scheme can be applied to any e-Learning subject having homogeneous learning objects and unidimensional test items. In order to construct the system, we present an operation scenario using the proposed system architecture with the essential databases and agents.

Monitoring and Analysis of 3kW Grid-Connected PV System for Performance Evaluation

  • So Jung-Hun;Jung Young-Seok;Yu Gwon-Jong;Choi Ju-Yeop;Choi Jae-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.57-62
    • /
    • 2005
  • Grid-connected photovoltaic (PV) systems were installed and monitored at the field demonstration test center (FDTC) in Korea in October 2002. Before long-term field testing of installed PV systems, the performances of PV components were evaluated and compared through short-term performance tests of each of the PV system components such as power conditioning system and PV module under standard test conditions. A data acquisition system has been constructed for measuring and analyzing the performance of PV systems to observe the overall effect of environmental conditions on their operation characteristics. Performances of PV systems have been evaluated and analyzed not only for component perspective (PV array, power conditioning unit) but also for global perspective (system efficiency, capacity factor, electrical power energy) by review of the field test and loss factors of the systems. These results indicate that it is highly imperative to develop an optimum design technology of grid connected PV systems. The objective of this paper is not only to evaluate and analyze the performance of domestic PV systems application through long-term field testing at FDTC but also to develop evaluation, analysis and optimum technology for long-term stability and reliability of grid-connected PV systems in Korea.

A Study on Performance Analysis of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구)

  • So, Jung-Hun;Choi, Ju-Yeop;Yu, Gwon-Jong;Jung, Young-Seok;Choi, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.