A study on Standards for Pilot Practical Test;Focused on the references for flight training and evaluation (조종사 실기시험 표준자료에 관한 연구;비행교육 및 평가에 필요한 표준자료를 중심으로)

  • Park, Soo-B
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • The purpose of the study is to show the need for the development of standard materials which can be used for flight training and pilot practical tests in the future. In this paper the flight training and evaluation references of flight training institutes certified by the Ministry of Construction and Transportation(MOCT) are compared with references of the international organization such as ICAO and FAA. As a result it is found that the flight schools certified by the MOCT have used different references for flight training and evaluation. Therefore, this study suggests creation and operation of an expert advisory group to develop new standards for flight training and evaluation, so called " Flight Training Manual", in Korea.

  • PDF

A Study on the Flame Monitoring System Development (화염감시 시스템 개발에 관한 연구)

  • 백운보;황이철;이승종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.60-66
    • /
    • 2004
  • Increased energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Simultaneously low NOx modification, installed due to stricter environmental legislations, require very careful combustion management. The flame diagnostics system has been developed specially to meet these requirements. We aimed at gaining the relationship between burner flame image and emissions such as NOx and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace, the system was observed to be effective for evaluating the combustion conditions.

Design and Performance Test of Vacuum Control Valve for Electron Beam Lithography (전자빔 가공기의 진공제어 밸브설계 및 특성평가)

  • Lee Chan-Hong;Lee Hu-Sang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.777-780
    • /
    • 2005
  • The high vacuum in a electron beam lithography is basic condition, because electron beam vanish by collision with air molecules in generally atmosphere. To make high vacuum state, the vacuum control valve is essential. Most vacuum control valve are manual units. So, user of manual vacuum valve must have understanding vacuum process to change from low vacuum to high vacuum state. The user of electron beam lithography are troubled with operation of manual vacuum valve, in case the vacuum chamber is frequently open. In this paper, the design and performance test of auto vacuum control valve for electron beam lithography are described. With the auto vacuum control valve, the high vacuum level can reach 2.8E-5 Torr.

  • PDF

Evaluations of Ride Comfort for the Rubber-Tired Light Rail Vehicle (고무차륜 경량전철 차량의 승차감 평가)

  • Kim Y.S.;Baek N.U.;Lim T.K.;Han S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.365-368
    • /
    • 2005
  • The dynamic model was developed to analyze vibration acceleration and ride comfort during the operation of rubber-tired light rail vehicles. The ride comfort for standing passengers was analyzed in accordance with ISO 2631-1, UIC 513R, and CEN Draft prENV 12299 using this model. The result was applied to the detail design of Korean-standard, rubber-tired light rail vehicles, and the detail specifications related to ride comfort was determined based on this result. The ride comfort test was performed along the test track by using 2 car-train, and its result was compared with that of the ride comfort analysis, verifying the validity of the developed dynamic model. It was also verified whether or not the developed Korean-standardized, rubber-tired light rail vehicle met specified target specifications on ride comfort.

  • PDF

Development of the slitting device on separation study of pellet and hull (펠릿과 헐의 분리 연구를 위한 슬리팅 장치 개발)

  • 정재후;윤지섭;홍동희;김영환;진재현;박기용
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.236-239
    • /
    • 2003
  • The spent fuel slitting device is an equipment developed in order to feed UO$_2$pellet to the dry pulverizing/mixing device. In this study, we have compared and analyzed the handling method of the slitting and that of the pellet and hull, processing time, separating time for 20kgHM, the number of blades, on the existing slitting device using in DUPIC, and spent fuel management technology research and test facility. Also, we have compared and analyzed about an advantage and weak point, designing and producing, processing, establishment, operation, maintenance about the vertical and horizontal slitting device. Based on these results, we have developed the vertical slitting device. By using the results, we have enhanced the slitting processing time(over 40%)in comparison with DUPIC device, and it will is effectively applied to available data for designing and producing of the hot test facility.

  • PDF

Certification and Assessment Plan of Dependability Management System IEC 60300 (신뢰성 경영시스템 IEC 60300의 인증 및 평가 방안)

  • 김종걸;김동철
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.2
    • /
    • pp.103-114
    • /
    • 2004
  • IEC 60300 series, the international standards on reliability management system are newly developed and introduced rapidly worldwide. In order to meet this fast-changing situation, it is necessary to apply them to the Korean industries effectively. It includes the establishment of the infrastructure such as documentation of Korean Standards, introduction of test equipments and test manuals, accreditation of the certification bodies and training of the specialists etc. IEC 60300 is upgraded management system of the ISO 9000 and ISO 14000. In this regard, the Korean companies which were certified with the ISO 9000 or 14000 should endeavor to find new strategies and methods to be certified with IEC 60300. This paper introduces a Quantitative method of estimating the level of the reliability management system by applying the MIR(Maturity Index on Reliability) technique. This enables the estimation of the operation level of the system and can upgrade the maturity level of it.

A Study of Korean Standard Speech Evaluation(kSNAP test) for Cleft Palate speaker (구개열 언어 평가의 표준화 연구 : kSNAP 테스트를 중심으로)

  • Shin Hyo-Keun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • Some children with Cleft Palate have shown a speech disorders after repaired surgical operation. A diagnostic evaluation of speech in children with cleft palates is important in preventing speech disorders. However, standard speech evaluation form for children with cleft palates has not yet developed in Korea. The purpose of this study is to make the standard speech evaluation form for children with cleft palates. Thirty control children group and ten children with cleft palate participated in this experiment. The test words are composed of meaningless two syllabic words containing the three different types of korean stop consonants,

  • PDF

Development of Electric safety monitoring system for reducing the electrical fire at traditional market (재래시장 전기화재 감소를 위한 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.259-262
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of traditional market developed the electric safety monitoring system which is suitable in traditional market. With for this did the actual condition investigation about electrical equipment of traditional market and we constructed Test-bed for testing reliability of electric safety monitoring system. Also experiment led in Test-bed and confirmed a stability. This paper following will be used with the data for the reliability security of the electric safe system operation which follows in the traditional market actual proof equipment construction which will be advanced.

  • PDF

A Study on the Operating Characteristic of RCB by Synthesize Harmonic Current (복합고조파에 의한 누전차단기의 동작 특성 연구)

  • Yoo, Jae-Geun;Choi, Myung-Il;Park, Chee-Hyun;Son, Jae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • This paper analyze the operating characteristic of RCB due to the synthesize harmonic current. The RCB of rated sensitivity electric current with 30[mA] test to operating characteristic by synthesize harmonic current and it analyzed the tripping operation due to a harmonic current. The test result, the operating current of RCB changed by synthesize harmonic current.

Inspection of the Diagnosis Report for Life Assessment of Engine Generator (내연발전기 건전성 판정을 위한 종합 진단결과 고찰)

  • Lee, Young-Jun;Ju, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.96-99
    • /
    • 2010
  • This paper presents evaluating procedure for engine generator operated over 13 years which are usually installed at the island and therefore, isolated to the main distribution line. To decide continual operation of the generator, their diagnosis results should guarantee safety running. So the determination of criteria for continual usage or replacement is essential for economical and reliable maintenance. We present all the courses of evaluating the condition which includes the processes from acquiring basic data to comprehensive determination of generators. All the test was applied to serial number 3 generator in Jodo Engine Power Plant.