• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.047 seconds

Analysis on the Discharge Capacity of Vertical Drains Installed in the Field (현장에 타설된 연직배수재의 통수능력 분석)

  • 박영목;진규남;정하익;정길수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.512-519
    • /
    • 2000
  • The discharge capacity of vertical drains installed in the field is reduced with time elapsed after installation due to deformation of drains and clogging effect. Discharge capacity of two types of vertical drains was analysed about three years after installation in the subsoil. Discharge capacity of two types of vertical drains were measured by small, middle, and large scale test apparatus. The results indicate that the discharge capacity of vertical drains after three years operation dramatically decreased compare to the initial discharge capacity.

  • PDF

Information Content of Commercial Paper Credit Rating Changes In Korea (우리나라 기업어음등급평가의 정보효과 검증)

  • 박범호;최호석
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2000.10a
    • /
    • pp.89-92
    • /
    • 2000
  • The purpose of this thesis is to investigate the information content of commercial paper credit rating changes of Korean firms. The result shows neither sinificant daily abnormal returns nor significant cumulative daily abnormal returns over the test window. This ind icates that commercial paper rating changes are not informative to investors. A sensitivity analysis conducted for the portfolio of subsample shows a similar result. This thesis, however, may contribute to the better operation of Korean financial market by providing several directions to establish credit-based financial transactions.

  • PDF

A Study on the Intelligent High Voltage Switchboard for Custormer (고압 수용가용 배전반의 intelligent화 연구)

  • Byun, Young-Bok;Joe, Ki-Youn;Koo, Heun-Hoi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.444-446
    • /
    • 1994
  • This paper describes the design of a digital multifunction controller for the intelligent high voltage customer switchboard and proposes a relaying algorithm for high impedance faults using back-propagation neural network. The hardware design uses the three microprocessors and global memory architecture to achive real time operation and control 4 feeders. The controller uses a 64-point radix-4 DIF FFT algorithm to measure the harmonic and relay parameters. Synthesized fault current waveforms are used to train and test the back - propagation network.

  • PDF

SART(SEARCH AND RESCUE RADAR TRANSPONDER)의 개발에 관한연구

  • 임종근
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1995.04a
    • /
    • pp.93-108
    • /
    • 1995
  • SART(Search and Rescue Radar Transponder) is a radar transponder capable of operating in the 9GHz band which is one element of GMDSS. the fundamental function of the SART is to indicate its position. Thus it is so much available to assist SAR operation when an emergency and casualty occur at any sea area, In the thesis we designed manufactured each part of circuit to develop the advanced SART and configured to test the characteristics in many ways, As the results of detailed things we confirmed that the developed SART could be high possibility of production.

Thermochemcial Characteristics of Rocket Nozzle Flow and Methods of Analysis (로켓 노즐 유동의 열/화학적 특징 및 해석 기법)

  • Choi Jeong-Yeol
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.144-148
    • /
    • 2001
  • Characteristics of high temperature rocket nozzle flow is discussed along with the aspects of computational analysis. Three methods of nozzle flow analysis, frozen-equilibrium, shifting-equilibrium and non-equilibrium approaches, were discussed those were coupled with the methods of computational fluid dynamics. A chemical equilibrium code developed for the analysis of general hydrocarbon fuel was coupled with three approaches of nozzle flow analysis, and a test was made for a bell nozzle at typical operation condition. As a results, the characteristics of the approaches were discussed in aspects of rocket performance, thermal analysis and computational efficiency.

  • PDF

철도차량의 비상제동거리 해석 시스템

  • 진원혁;이성창;김대은
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.747-750
    • /
    • 1995
  • As railway trains run faster high performance braking system are necessary because more energy needs to be dissipated due to increased kinetic energy. In this work a portable computer based prediction system for emergency braking distance has been developed. The algorithm for the system is based on braking theory and empirical results of actual braking test. The computer is connected to the sensors to measure the velocity and the braking pressure in real train. It is expected that this system will be utilized to predict emergency braking distance during actual operation of the train

  • PDF

System Identification of a Diesel Engine -Simulation Study- (디젤 기관(機關)의 계통식별(系統識別) -시뮬레이션 연구-)

  • Cho, H.K.;Smith, R.J.;Marley, S.J.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.4
    • /
    • pp.281-289
    • /
    • 1990
  • A frequency-domain, system-identification method using a binary multifrequency signal was developed to find the transfer function between smoke intensity and throttle position in a diesel engine. This paper describes the simulation study performed to test the identification method developed. With an assumption of a diesel operation in a limited region about the normal operating state, the linear theory was adopted. Because that air fuel ratio is one of the most important operating variables causing smoke production in diesel combustion, single-input and single-output model was adopted.

  • PDF

154KV개봉. 오류 지중송전선로 준공보고

  • 김성곤;정수근
    • 전기의세계
    • /
    • v.29 no.11
    • /
    • pp.693-698
    • /
    • 1980
  • We T.E.C. have commenced to develop the O.F. cable in April, 1977. Now we have finished the Type-Test and produced in full-operation of 154KV 1x600mm$^{2}$ and 154KV 1x1200mm$^{2}$ O.F. cables. Especially we have completed pulling and splicing of the 24.82kms O.F. cable in KaeBong-OuRyu Route, and now it is operating well. This has important meaning that Extra High Voltage Under Ground Transmission Line has constructed by domastic engineers for the first time in Korea. Thank to arrange and publish it, and hope it can be helpful to the related.

  • PDF

Research and Development of Superconducting Magnetic Energy Storage system(SMES)

  • Isojima, Shigeki
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.40-45
    • /
    • 1998
  • This paper describes a collaborative work between SEI and KEPCO on the Superconducting Magnetic Energy Storage system (SMES). We have studied two types of magnets. One is the 400kJ class LTS-SMES for testing the power stabilization operated at liquid helium temperature (4.2K) and the other is the 100J class HTS-SMES for confirming the possibility of applying HTS wire to SMES at liquid nitrogen temperature (77k). In this paper, the design of the magnet and the test results are described. Each magnet performed completely at rated operation.

  • PDF

A study on the characteristic comparision of systems which measure the temperature of coal powder in feader lines of boiler (급탄관 온도 측정시스템의 특성 비교분석에 관한 연구)

  • 오면택;이복규;이원빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.597-600
    • /
    • 1996
  • This study has compared the two types of systems which measure the temperature of coal powder in feeder lines of boiler and analyzed operating data. We used RTD(Resistance Temperature Detector) and optic sensors to measure the temperature. From the characteristic comparison of data, field test and system operation, we confirm that the latter is more efficient than the former.

  • PDF