• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.049 seconds

Shoulder Range of Motion in Postmastectomy Patients (유방암 절제술 후 환자의 어깨관절 가동범위 조사)

  • Eom, Ae-Yong;Lee, Eun-Ok
    • Asian Oncology Nursing
    • /
    • v.4 no.1
    • /
    • pp.62-70
    • /
    • 2004
  • The purpose of this study was to use as a basic data to develop suitable nursing intervention program and decide an appropriate intervention time after assessing shoulder range of motion in postmastectomy from 2 weeks to 3 month. 147 patients are chosen as study subject among patients who were in recovery of 2weeks, 1month, 2months and 3 months after surgical operation which is modified radical mastectomy. Data were collected at oncology medicine local and general surgery local in Seoul National University Hospital from May, 2003 to October, 2003. The range of motion of the shoulder(flexion, extension, abduction, internal rotation, external rotation) were examined. Analysis of data that shoulder range of motion average and standard deviation, percentage of the unaffected side and affected side compare with normal shoulder range of motion. Paired t-test was adopted to analyze the difference between affected side and unaffected side. Conclusion from this study is as following, 1. The most serious problem was external rotation (0.56%) and internal rotation is the next (19.9%) in 5 kinds of shoulder range of motion in 2 weeks after surgical operation 2. There was no difference in internal rotation after post operation 3 months but there were differences and shown to recover more than 90% in flexion and abduction. Also shoulder function incresed in flextion less than 80% and more than 80% in external rotation. As this study finding was shown that shoulder range of motion did not get back perfectly except of internal rotation and extension in point of 3 months after breast cancer surgical operation. External rotation was specially shown the lowest result so it is needed to exercise for improving their physical functioning recovery in postmastectomy patients. And it is suggested to study for helping to postmastectomy patients' physical and psycosocial functions with the early rehabilitation program which is based on these results.

  • PDF

A Study on the Development and Effect of Number-Operation Games for Mathematical Creativity of Gifted Students (초등 수학 영재의 창의성 향상을 위한 수 연산 게임 개발 및 적용에 관한 연구)

  • Kim, Yong Jik;Cho, Minshik;Lee, Kwangho
    • Education of Primary School Mathematics
    • /
    • v.19 no.4
    • /
    • pp.313-327
    • /
    • 2016
  • The purpose of this study is to develop the number-operation games and to analyze the effects of the games on mathematical creativity of gifted elementary students. We set up the basic direction and standard of mathematical gifted creativity program and developed the 10 periods games based on the mathematically gifted creative problem solving(MG-CPS) model. And, to find out the change of students' creativity, the test based on the developed program and one group pretest-posttest design was conducted on 20 gifted students. Analysis of data using Leikin's evaluation model of mathematical creativity with Leikin's scoring and categorization frame revealed that gifted students's creativity is improved via the number-operation games.

A Case Report of Oriental Medical Treatment for the Left Lower Limb Monoplegia after Herniated Intervertebral Disc Operation at L-spine (요추 추간판 탈출증 수술 후 발생한 좌하지 단마비의 한의학적인 치료 증례보고)

  • You, Kyung-Gon;Park, Min-Jung;Jung, Il-Min;Yeom, Seung-Ryong;Kwon, Young-Dal
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.4
    • /
    • pp.227-239
    • /
    • 2011
  • Objectives: This study was performed to report the case of oriental medical treatment for the left lower limb monoplegia after herniated intervertebral disc(HIVD) operation at lumbar(L)-spine. Methods: A 38-year-old man who underwent lumbar HIVD operation at a hospital admitted with motor weakness of left lower limb, a little decreased left leg radiation pain and low back pain. We treated him by acupuncture, herbal medicine, bee venom injection moxibustion, cupping treatment physical therapy and measured with visual analogue scale(VAS), Oswestry disability index(ODI), Roland-Morris disability questionnaire(RMDO) and manual muscle test(MMT) from 8th February to 4th May 2011. Results: After treatment most symptoms decreased, VAS score changed from 10 to 3, ODI changed 71% to 37% RMDQ changed 13 to 8 and MMT changed from 3 to 5. Conclusions: Our study suggested that oriental medical treatments are significantly applicable to the monoplegia and pain after lumbar HIVD operation. And further studies ire required to identify underlying mechanism of the treatment.

The development of full-scope replica simulator for variable supercritical pressure once-through fossil power plants (변압 관류형 초임계압 화력발전소 전범위 시뮬레이터 개발)

  • Lee, Jung-Kun;Ahn, Yeon-Shik;Jung, Hoon;Lee, Yong-Kwan;Han, Byoung-Sung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.3
    • /
    • pp.392-399
    • /
    • 1998
  • A full-scope replica type simulator whose MCR(main control room) has the same features and operation functions as MCR of the reference power plant has been developed for a fossil power plant. This simulator was developed with the model of Poryung Fossil Power Plant #3,4 which is the standard model of the Korean fossil power plant. It is the first localized simulator for the supercritical, variable boiler pressure type fossil power plant. The simulator provides various kinds of accidents which are in normal plant operation and thus enables operators to recover or reduce possible damages. To design and develop this kind of simulator, we need to integrate high technologies such as system analysis, plant operation and system integration of mechanics, physics, computer science. CASE(Computer Aided Software Engineering) tools were used to develop the dynamic model. This simulator will greatly contribute to the improvement of the safety and efficiency of the fossil power plant by implementing operator training. In this paper, the outline of software and hardware configuration and characteristics of the simulator are described, and the results of 30%, 50%, 75%, 100% load operation test will be discussed.

  • PDF

Long-term radiographic evaluation of infrabony defect treated by flap operation (치주판막술에 의해 치료된 골연하 결손부의 장기적 방사선학적 변화 양사의 관찰)

  • Bae, Sang-Ryul;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.429-436
    • /
    • 2008
  • Purpose: The goal of periodontal regenerative therapy is to replace bone, cementum, and periodontal ligament on a previously diseased root surface, which has suffered the loss of these supporting structures. To accomplish the regeneration, a number of surgical procedures have been advocated throughout the years. There seems to be a potential for some spontaneous periodontal tissue regeneration in the bottom of periodontal defect following open flap debridement alone. The aim of this study was to analyse the radiographic bone changes over 2-year after flap operation. Material and Methods: Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of infrabony defect(s). forty two sites of 33 patients aged 26 to 65 (mean age 45.5) were treated by flap operation with or without osseous surgery. Baseline and over 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, gender, defect depth, defect angle) using the paired t-test were examined. Result: We observed 0.74 mm of bone fill, 0.66 mm of crestal resorption, 1.40 mm of defect resolution, and 27% of percentage of defect resolution. Mandible, women, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. Conclusion: The results of this study suggest that the use of flap operation did enhance the outcome in terms of radiographically detectable bone fill. Both treatment resulted in some loss of crestal bone height.

Dynamic Characteristics of a Hydraulic Fishing Winch Simulator (유압식 어로 윈치 시뮬레이터의 동적 거동 특성)

  • LEE Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.4
    • /
    • pp.330-336
    • /
    • 2004
  • To meet the increasing demand from various fishing fields for training of fishing equipment operators, a fishing winch simulator was designed to train maritime students in the correct and safe operation of hydraulic winches under various load conditions related to fishing operations. The aim of this study is to describe the basic dynamic characteristics of the newly developed hydraulic fishing winch simulator and particularly to analyze the mechanical responses produced on the winch operation controls. The winch simulator consists of two winch units, a computer control and data acquisition system, a control consol and other associated mechanisms. When one winch is in hauling mode, the other one will always be in loading mode. The revolution speed of the hauling winch was controlled by a proportional directional control valve, and the braking torque of the loading winch was controlled by a proportional pressure control valve. The simulation experiments indicated that the dynamic characteristics of the hauling winch followed the braking response characteristics of the loading winch. The tests also showed that the warp speed and tension linearly depend on the pressure differential across the motor of the loading winch controlled by operating the proportional pressure control valve during the hauling operation. The experience gained from various training courses showed that the fishing winch simulator was very realistic and it was valuable for training novice winch operators. The results of the winch simulation exercise were recorded and used to evaluate the training on the operation and handling of the winch system. From these test results, we concluded that the tension acting on the warp during hauling operations can successfully be simulated by controlling the pressure differential across the motor with step changes of the control input signal to the proportional pressure control valve of the loading winch.

Mobile monitoring system of the Dual LED marine lantern (이중 LED 등명기의 휴대용 모니터링 시스템)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1948-1954
    • /
    • 2014
  • Advances in IT technology and modernization of AtoN(Aids to Navigation) facility has increased the unmanned operation of AtoN. However, in AtoN facilities, accessibility is low and it is not able to perform maintenance on the bad weather at the time. In connection with this, in this paper, by applying the protocol of the enhanced dual LED marine lantern, we implemented the short-range monitoring system for a mobile terminal. System implemented in this paper can be carried out confirm the operation status, inspection or control of the dual LED marine lantern at a short distance. Also, it is possible to reduce maintenance costs and prevent accidents during inspection of AtoN. At the same time, it enables the operation test easily without disassembling the product, effective AtoN operation is possible. We tested the system that has been implemented using prototype of the LED marine lantern and confirmed state informations and controlled the behavior of the system in real time.

Study of Loss of Free Flap and Safer Timing of the Operation in Electrical Injury (전기화상에서 시행한 유리피판의 소실과 재건시기에 대한 연구)

  • Chung, Eui Young;Lee, Jong Wook;Koh, Jang Hue;Seo, Dong Kuk;Chung, Chan Min;Jang, Young Chul;Oh, Suk Joon
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.567-572
    • /
    • 2005
  • An electrical burn used to result in the damage of the skin and underlying deep soft tissue injury. Thus, in order to preserve devitalizing tissues and promote the structural survival free flaps with ample blood supply are frequently employed. However, early unpredictable vascular injury and progressive tissue necrosis may cause the free flaps full of hazards. We applied 50 free flaps upon 41 acute electrical burn cases between 1998 and 2004. Injured areas, timing of operation and causes of flap loss were studied. The victim's ages ranged from 13 to 60 years. (an average 37.8 years) Thirteen out of 50 free flaps were lost totally: three cases were due to arterial insufficiency and ten venous congestion. Total loss of flaps were observed in 5 of 12 cases in the postoperative 3 weeks, 6 of 20 cases between 3 and 6 weeks and 2 of 18 cases after 6 weeks. In three of 12 cases the free flap was lost partially in the postoperative 3 weeks, 4 of 20 cases between 3 and 6 weeks and 1 of 18 cases after 6 weeks. The result was statistically significant by a T-test (p<0.05). This study showed that timing of the operation is accountable for the loss of free flap. It is most important to conduct the free flap procedure on an electrical injury at the time when the recipient vessel is definitely discernible and intact so as to minimize the loss of flap and spare the structures.

Image Data Transmission and Receiving System of KITSAT-3-Performance of initial operation (우리별3호 영상데이터 송수신 시스템 - 초기운용 성능 실험)

  • 신동석;김탁곤;최욱현
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.3
    • /
    • pp.209-216
    • /
    • 1999
  • KITSAT-3, the third satellite of KITSAT series which has been developed for the last four and half years with purely Korean design and implementation technology, was launched successfully at last. All subsystems were tested and validated during the initial operation of the satellite. During the initaial operation phase, the Earth imaging camera on board KITSAT-3 acquisited several tens of scenes all over the world and transmitted the image data to ground station. The quality of images and the reliability of data transmission-reception system were tested qualititively and quantititively, respectively. In this paper, we summarize the camera, data handling, on-board memory, and image data transmission system of KITSAT-3 as well as the image receiving and archiving system in ground station. The error rate of image data transmission and reception was tested during the initial operation phase. The average data transmission error rate satisfied the initial requirement of less than 1%. The error rate will be reduced through the continuous work of test and stabilization of the ground system hardware.

Development of On-board Computer Module for Formation Flying and Cluster Operation Nano-satellites (초소형 위성의 편대 및 군집 운용을 위한 모듈형 온보드 컴퓨터 개발)

  • Oh, Hyungjik;Kim, Do-hyun;Park, Ki-Yun;Lee, Ju-in;Jung, Insun;Lee, Seonghwan;Park, Jae-Pil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.10
    • /
    • pp.728-737
    • /
    • 2019
  • In this study, the minimized on-board computer (OBC) module for integrated navigation is developed, which provides satellites' relative position information in formation flying and cluster operation situations. The scalability is considered to apply the user-selected wireless communication module and Global Positioning System (GPS) receiver for navigation, while considering to meet the structural design standard of nano-satellites. As a result of the product development and production, the processing speed of integrated navigation and real-time data synchronization is satisfied for cluster operation nano-satellites by using micro controller unit (MCU). From a heat/vacuum, vibration and radiation test, the OBC was confirmed to be operated in space environments. From these results, a mass production system of OBC was made which is a key part of development on satellite formation flying and cluster/constellation missions that the community demands are increasing.