• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.037 seconds

Test method for Motor/controller for Electric Vehicle (전기자동차용 전동기/제어기의 시험 방법)

  • 오성철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.328-335
    • /
    • 2003
  • Test procedure for Electric Vehicle(EV) motor/controller has been developed. Most of existing standards mainly focus on minimum requirements for safe operation. However, detailed test procedures are not covered in the standard. In order to develop test items, methods and procedures which should be strictly applied to EV motor and controller, existing standards have been reviewed by the expert group in Korea. Based on their feedback, standard test procedure was proposed. Test procedure especially for combined motor and controller has been proposed. As a load lot the tested motor, M-G set, eddy current type engine dynamo and AC dynamo were used. Test procedures for the driving cycle test and regeneration test were proposed.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

A Study on the operation and Maintenance system for optical subscriber loops using a broadband light source (넓은 대역 광원을 이용한 광 가입자 선로 운용보전 시스템에 관한 연구)

  • 이용기;이영호;박봉근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3B
    • /
    • pp.504-509
    • /
    • 2000
  • This paper presents a noble operation and maintenance system for the optical subscriber loops and its feasibility through several experiments. In this system, a broadband CW (Continuous Wave) light source I used as monitoring of testing signals. and a FGF(Fiber Grating Filter) of which reflective wavelength is independent, is inserted somewhere in each subscriber loop for the reflection of monitoring of testing signals. The propose of the system is quick decision. whether the loop is just fault or not. rather than detailed information of loop state. At present, most of operation and maintenance system for the optical subscriber loops adopts OTDR(optical time domain reflectometer) for testing function. the OTDR is useful for detailed test, but not adequate for simple test because of long testing time . And it is difficult to test PON network by using general OTDR that has a single-wavelength light source. Compared to using OTDR, the proposed system can afford to shorten testing time and to test PON network. Moreover, we can cut down the system cost by simplifying circuits of the optical light sources. Our results show that the proposed system operates well according to the purpose mentioned above.

  • PDF

Analysis of Reflux Cooling in the SG U-Tubes Under Loss of RHRS During Midloop Operation with Primary System Partly Open

  • Son, Young-Seok;Kim, Won-Seok;Kim, Kyung-Doo;Chung, Young-Jong;Chang, Won-Pyo
    • Nuclear Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.112-127
    • /
    • 1998
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic codes, RELAP5/MOD3.2 and CATHARE2V1.3U, to the analysis of thermal-hydraulic behavior in PWRs during midloop operation following the loss of RHRS. The codes simulate an integral test, BETHSY 6.94, which was conducted in the large scale test facility of BETHSY in France. The test represents the accident where the loss of RHRS occurs during midloop operation with the pressurizer and upper head vents open and the sight level indicator broken. Besides, the hot legs are half filled with water and the upper parts of the primary cooling system are filled with nitrogen, with a letdown line open and only one SG available. The purposes of this study are to understand the physical phenomena associated with reflux cooling in the 5G U-tubes when noncondensable gas is present under low pressure and to assess the applicability of the codes to simulate the loss of RHRS event by comparing the predictions with the test results. The results of the study may contribute to actual applications for plant safety evaluation and description of the emergency operating procedure.

  • PDF

Starting and Normal Operation Control Logic Research of Small Gas Turbine Engine (소형 가스터빈엔진의 시동 및 정상운용구간 제어로직 연구)

  • Lee, Kyungjae;Rhee, Dong-Ho;Kang, Young Seok;Kho, Seonghee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.5
    • /
    • pp.1-9
    • /
    • 2021
  • As part of the commercialization research of small gas turbine engines, starting and normal operation control logic research of small gas turbine engine was conducted. It was investigated how the igniter, starting motor and fuel pump/valve are controlled during the ignition and normal operation process and it was applied to the prototype engine control unit(ECU) of the small gas turbine engine for commercialization research. Based on the ground test results, an ECU for flight test is being developed, and after completion of the development, an altitude test will be performed through an altitude test facility of Korea Aerospace Research Institute.

A Study on FMECA Application to Life Time Test of MCCB (배선용 차단기 수명평가를 위한 FMECA 적용 방안에 대한 연구)

  • Seo, Jung-Youl;Shin, Hee-Sang;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2063_2064
    • /
    • 2009
  • Recently, load circuits and components of customer are various. Therefore failures of ELB(Earth Leakage Breaker) and MCCB(Molded case circuit breakers) are more frequent. Lite time of MCCB even if there is same units differ from environment, condition of operation. FEMCA is a efficiency method of system operation or maintenance for system reliability. We study on FMECA procedures and method. In this paper, we focused on FMECA application to MCCB life time test.

  • PDF

The Method of Automathic Operation of Coagulant Dosage by the quality of water (수질에 따른 응집제 주입 자동운영 방안)

  • Jun, Uk-Pyo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.278-283
    • /
    • 2005
  • Generally Jar-Test is available to determine the coagulant dosage rate. Disadventages associated with Jar-Test are that regular samples have to be taken requiring manual intervention and the limitation to feedback control. To deal with this difficulty, determined optimized dosage rates of coagulant to investigates the union operation method of the statistical equation which uses the multi-regression method and the SCD.

  • PDF

DEVELOPMENT OF KITSAT-1 AND 2 MECHANICAL SYSTEM AND RESULTS OF ENVIRONMENT TEST (우리별 1, 2호의 기계구조 개발 및 환경시험 결과)

  • 배정석;이동우;이상현;박성동;최순달
    • Journal of Astronomy and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.94-104
    • /
    • 1996
  • The satellite experiences the launch environment such as vibration, acceleration, shock induced by rocket and the orbit environment such as high vacuum, no gravity, high temperature and cryogenic. Therefore, the satellite should be designed and manufactured to endure such environments. Also, special care must be taken on the assembly of parts and subsystem. Finally, we describe the environment test of microsatellite to ensure the reliable operation during launch period as well as in-orbit operation.

  • PDF

The Method of Optimum Operation of Coagulant Dosage Facility (응집제 주입설비 최적 운영방안)

  • Jun, Uk-Pyo;Oh, Sueg-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.275-281
    • /
    • 2004
  • Generally Jar-Test is available to determine the coagulant dosage rate. Disadventages associated with Jar-Test are that regular samples have to be taken requiring manual intervention and the limitation to feedback control. To deal with this difficulty, determined optimized dosage rates of coagulant to Investigates the union operation method of the statistical equation which uses the multi-regression method and the SCD.

  • PDF