• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.034 seconds

Status and test results of the HPRF system for PEFP 20MeV linear accelerator

  • Seol, K.T.;Kwon, H.J.;Kim, H.S.;Song, Y.G.;Cho, Y.S.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.10a
    • /
    • pp.915-916
    • /
    • 2005
  • The high power RF system for the PEFP 20MeV proton accelerator composed of the 3MeV RFQ and the 20MeV DTL has been installed. The klystron for the RFQ was tested up to 600kW and operated routinely to drive the RFQ in a pulse mode operation. The klystron for the DTL which consists of 4 tanks was tested up to 800kW in pulse mode operation. The pulse width and repetition rate was 50${\mu}s$ and 1Hz respectively. The high power RF system has been operated to drive each accelerating structure and will be used to accelerate 20MeV proton beam.

  • PDF

Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan (축류송풍기 부착형 공냉식 열교환기의 진동 저감)

  • Jung, Goo-Choong;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.75-81
    • /
    • 2000
  • Vibration problems induced by an air cooled heat exchanger with axial flow fan were investigated during the operation of a petrochemical plant. Two different studies were done; one was experimental field test and the other was theoretical verification. To find main cause of the blade passing frequency of the fan after installing additional blockage board at the air inlet of the axial fan, the frequency spectrum was measured. The vibrations of the blade passing frequency became higher. The natural frequency of driving support of the heat exchanger was theoretically calculated. It was approximately equal to the blade passing frequency. During the normal operation of the plant, it was impossible to modify the structure of the driving support. Instead, the blade number was increased to reduce vibration level. It increased the ratio of the forcing frequency to the natural frequency of the driving support over the resonance region.

  • PDF

Harmonics Measurement and Analysis on Industrial load Facilities (산업용 부하설비의 고조파 측정 및 분석)

  • Han, Wun-Dong;Ji, Pyeong-Shik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.133-139
    • /
    • 2006
  • Harmonics happened due to nonlinear systems such as UPS, SCR controlled motors, and fluorescent lighting in distribute power system is very important subject to optimal operation and control of power system. Harmonics sometimes make incorrect operation of protective relaying system under normal condition on power system. In this study, total harmonics distortion(THD) of power were measured and analyzed by the field test on electrical facilities which were installed at the rural industrial complex in Chungbuk province. In addition, the deprivation of power factor by harmonics and the content of THD which is measured at neutral line was researched.

  • PDF

Mirror-Switching Scheme for High-Speed Embedded Storage Systems (고속 임베디드 저장 시스템을 위한 복제전환 기법)

  • Byun, Si-Woo;Jang, Seok-Woo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • The flash memory has been remarked as the next generation media of portable and desktop computers' storage devices. Their features include non-volatility, low power consumption, and fast access time for read operations, which are sufficient to present flash memories as major data storage components for desktop and servers. The purpose of our study is to upgrade a traditional mirroring scheme based on SSD storages due to the relatively slow or freezing characteristics of write operations, as compared to fast read operations. For this work, we propose a new storage management scheme called Memory Mirror-Switching based on traditional mirroring scheme. Our Mirror-Switching scheme improves flash operation performance by switching write-workloads from flash memory to RAM and delaying write operations to avoid freezing. Our test results show that our scheme significantly reduces the write operation delay and storage freezing.

VIBRO-ACOUSTIC TROUBLESHOOTING SOLVES 5MW BOILERFEED PUMP TESTRING NOISE & VIBRATION PROBLEMS

  • Gielen, L.;Vandenbroeck, D.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.836-841
    • /
    • 1994
  • This paper describes the global vibro-acoustic troubleshooting approach, used to identify and separate different sources of noise and vibrations on a boilerfeed pump testrig. The pump serves for rotor dynamic research of a EC-funded BRITE-Euram profect. This approach resulted in the identification of local structural flexibilities in the connections between the machinery and the base plate. The relative importance of the modes during normal operation is revealed by comparison with operational deformation shapes. The use of sound intensity mapping allowed to calculate the total sound power and to rank the equipment according to its sound power contribution. High acoustic levels were found and related to the fluid drive and to the piping system. Modification of the piping section resulted in a reduction of noise and vibration levels along the test loop and smooth operation in a wide suction pressure range.

  • PDF

An Islanding Detection Method for Distributed Generations Using the Voltage Unbalance (전압 불평형율을 이용한 분산전원의 고립운전 검출 기법)

  • Jang S. I.;Park J. K.;Kim K. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.42-44
    • /
    • 2004
  • This paper introduced and proposed the voltage unbalance of DC terminal output as new monitoring parameter for power islanding detection. This paper also presented a simple and novel detection algorithm, which effectively combines the detection results of the conventional parameter, voltage magnitude, and a newly proposed parameter. We tested the proposed method using several distribution network conditions including not only islanding operation conditions, but also non-islanding conditions of normal network load variations. The test results showed that the proposed parameters and algorithm are capable of correctly detecting the islanding operation not affected by variation of DG loading and also have a good selectivity for islanding conditions and non-islanding conditions.

  • PDF

Operational Status of 20mN class Ion Engine Subsystem for ETS-VIII

  • Ozaki, Toshiyuki;Kasai, Yukikazu;Nakagawa, Takafumi;Kajiwara, Kenichi;Ikeda, Masafumi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.511-518
    • /
    • 2008
  • The Engineering Test Satellite VIII(ETS-VIII) of Japan Aerospace Exploration Agency(JAXA) uses a 20mN class xenon ion engine subsystem(IES) for North-South Station Keeping(NSSK). The IES was modified for a larger satellite with longer lifetime based on the former IES. ETS-VIII, a three-ton class geosynchronous satellite with 10 years bus lifetime, was launched 18 Dec. 2006 JST; it reached the planned orbit and all bus systems were checked out. The IES showed good results and is now under normal operation. The total accumulated operation time of the IES in orbit was about 2300 hours till $19^{th}$ Dec. 2007.

  • PDF

Support of shaft process line Modeling for improving operation rate (Shaft 가공라인 자원 가동률 향상을 위한 모델링)

  • Lim, Sang-Baek;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.179-183
    • /
    • 2016
  • The purposes of this research are to modelize test system of SM TESTING by ARENA, software, input several items of specimen's testing process, resources of system and transfer loop, etc, give a hypothesis and then, obtain results reducing the efficiency of the whole system finally by overload of specific facilities in the testing system through the simulation so as to obtain several materials such as specimen and testing facility, transfer loop, etc. by simple and various forms without any necessity of numerical modelization. It will add facilities of over load and reduce facilities with low operation rate, so increase the efficiency of the system.

Control of Compressors and Electronic Expansion Valve considering the Safe Operation of a Tandem-type Air-conditioning system (텐덤형 냉방시스템의 안전운전을 고려한 압축기와 전자팽창밸브 제어)

  • Han, Do-Young;Kim, Jae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.675-680
    • /
    • 2006
  • Capacities of a tandem-type air-conditioner may be modulated by turning on and off of multiple compressors, and adjusting the position of a electronic expansion valve. In this study, control algorithms for compressors and a electronic expansion valve were developed by using fuzzy logics. The pressure control algorithm was also developed for the safe operation of compressors. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature,

  • PDF

Development of KITSAT-3 camera and current status of the operation (우리별 3호 지구관측 카메라 개발 및 운용 현황)

  • 이준호;유상근
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.382-388
    • /
    • 2001
  • KITSAT-3, launched at May 26 1999, has an earth observation optical payload named MEIS (Multi-spectral Earth Imaging System). The MEIS is a Managin mirror telescope of aperture size of 95mm, and it images the ground with the ground sampling distance of 13.8m over 48km at the altitude of 720km using three different observations bands. This paper first presents the design and then the optics, relating results of manufacturing, integration and test. Finally it briefly discusses the current status of MEIS operation.

  • PDF