A Study on the Deterioration Progress of Railway Arresters (철도용 피뢰기의 열화진전에 관한 연구)

  • Kil Gyung-Suk;Han Ju-Seop;Han Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1393-1395
    • /
    • 2004
  • Arresters are the best protective device on electrical power systems against transient overvoltages generated by lightning and/or switching operation. Nonetheless, arresters will be deteriorated due to absorption of moisture in the environments of its use, repetition in the protective operation to overvoltages, and some defects at manufacturing. It is therefore important to estimate the electrical characteristic changes of ZnO blocks. In this paper, an accelerated deterioration test by a standard lightning impulse current was carried out to extract parameters needed for diagnosing arrester deterioration, and leakage current components were measured. Total energy applied to the ZnO blocks at each time is 1,050[J] in 8/20[${\mu}s$] impulse current. From the experimental results, we proposed electrical parameters and leakage current level to diagnose arrester soundness.

  • PDF

Mechanism Design of Cube Satellite for Multi-deployable Structures and Autonomous System Operation after Launcher Separation (복수구조 전개 및 발사체 분리직후 시스템 자동운용을 위한 큐브위성의 메커니즘 설계)

  • Lee, Myoung-Jae;Jung, Hyun-Mo;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.20-25
    • /
    • 2013
  • In case of cube satellite, it is difficult to realize the same performance as commercial satellite due to its highly restricted unit accommodation space. To maximize the performance of the cube satellite, design concept considering the multi-function of satellite is required. In this paper, mechanism design of cube satellite which is applicable for the holding and release of multi-deployable structures has been proposed and investigated. In addition, a switch mechanism design for the autonomous system operation just after the cube satellite separation from P-POD has also been proposed. The effectiveness of the mechanism design for holding and release of multi-deployable structures has been demonstrated by EM test of the holding and release mechanism.

120W SSPA System Design for S-Band Uplink Application

  • Ahn Sang-il;Park Dong-Chul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.460-463
    • /
    • 2004
  • There is a trend to replace TWTA of SSPA in S-Band uplink application for satellite operation. KARI developed l20W full S-Band SSPA system in early 2004. This paper covers SSPA system design and its test results. Through tests, nominal gain of 57dB, gain stability of +/-1dB over frequency, and gain stability of +/-0.5dB over temperature were shown. IMD value of -16.5dBc, -19dBc were revealed in PI and P3 output operations. With meeting specifications, l20W SSPA is expected to be used in operational S-Band uplink application.

  • PDF

A study on low power and design-for-testability technique of digital IC (저전력 소모와 테스트 용이성을 고려한 회로 설계)

  • 이종원;손윤식;정정화;임인칠
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.875-878
    • /
    • 1998
  • In this thesis, we present efficient techniques to reduce the switching activity in a CMOS combinational logic network based on local logic transforms. But this techniques is not appropriate in the view of testability because of deteriorating the random pattern testability of a circuit. This thesis proposes a circuit design method having two operation modes. For the sake of power dissipation(normal operation mode), a gate output switches as rarely as possible, implying highly skewed signal probabilities for 1 or 0. On the other hand, at test mode, signals have probabilities of being 1 or 0 approaching 0.5, so it is possible to exact both stuck-at faults on the wire. Therefore, the goals of synthesis for low power and random pattern testability are achieved. The hardware overhead sof proposed design method are only one primary input for mode selection and AND/OR gate for each redundant connection.

  • PDF

An experimental study on the Bonding Strength and Strain of Coating Material according to Temperature Condition (온도조건에 따른 표면보호재의 부착강도 특성 및 변형 특성에 관한 실험적 연구)

  • Bae, Jun-Young;Kwan, In-Pyo;Kim, Kyung-Deok;Kang, Suk-Pyo;Kawk, Ju-Ho;Kim, Jung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.293-296
    • /
    • 2006
  • Normally, using coating material could result in different performance according to the various changes of environments or operation conditions. For these reasons, there are decreasing tendency for the durability, beauty and scenery of structures as the separation or exfoliation occurred after operation. Especially we must find out not only bond strength characteristics of coating material under temperature conditions but also bond strength reduction under heating-cooling repeat test because Korea has four distinct seasons. In this paper, the deformation and bond strength characteristics of coating material have been investigated. and we suggest some preliminary data of coating material for its best performance under various temperature condition.

  • PDF

Fatigue Crack Detection Test of Weldments Using Piezoceramic Transducers

  • KIM MYUNG HYUN;KANG SUNG WON;KEUM CHUNG-YON
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.4 s.65
    • /
    • pp.21-27
    • /
    • 2005
  • Large welded structures, including ships and offshore structures, are normally in operation under cyclic fatigue loadings. These structures include many geometric discontinuities, as well as material discontinuities due to weld joints. The fatigue strength at these hot spots is very important for the structural performance. In the past, various Non Destructive Evaluation (NDE) techniques have been developed to detect fatigue cracks and to estimate their location and size. However, an important limitation of most of the existing NDE methods is that they are off line; the normal operation of the structure has to be interrupted, and the device often has to be disassembled. This study explores the development of a structural health monitoring system, with a special interest in applying the technique to welded structural members in ship and offshore structures. In particular, the impedance based structural health monitoring technique that employs the coupling effect of piezoceramic (PZT) materials and structures is investigated.

Real-time implementation of the G.723.1 voice coder using DSP56362 (DSP56362를 이용한 G.723.1 음성코덱의 실시간 구현)

  • Lee, Jae-Sik;Son, Yong-Ki;Chang, Tae-Gyu;Min, Byoung-Ki
    • Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.225-234
    • /
    • 2000
  • This paper describes the fixed-point DSP implementation of a CELP(Code-excited linear prediction)-based speech coder. The effective realization methodologies to maximize the utilization of the DSP's architectural features, specifically parallel movement and pipelining are also presented together with the implementation results targeted for the ITU-T standard G.723.1 using Motorola DSP56362. The operation of the implemented speech coder is verified using the test vectors offered by the standard as well as using the peripheral interface circuits designed for the coder's real-time operation.

  • PDF

Selection and Noise Evaluation Methods of the System Electronic Cooling Fan (시스템 전자 냉각 팬의 선정 및 소음 평가 기법)

  • Lee, Chan;Yun, Jae-Ho;Gwon, Oh-Kyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.3 s.42
    • /
    • pp.33-38
    • /
    • 2007
  • Fan selection procedure and fan noise evaluation method are presented for the system electronic cooling by combining FNM(Flow Network Model) and fan noise correlation model. Internal flow paths and distribution in electronic system we analyzed by using the FNM with the flow resistances for flow elements of the system. Based on the fan operation point predicted from the FNM analysis results, the present fan noise model predicts overall sound power, pressure levels and spectrum. The predictions of the flow distribution, the fan operation and the noise level in electronic system by the present method are well agreed with 3-D CFD and actual test results.

Doppler Rader Location of Weather Information System for Power System Operation (전력계통(電力系統) 기상정보(氣象情報)시스템의 도플러레이다 위치(位置) 선정(選定))

  • Kim, Yeong-Han;Lee, Hyo-Sang;Kim, Jai-Young
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.206-210
    • /
    • 1989
  • With the economy expands and the increasing living standard of people, the better quality of electricity which is closely related with weather conditions should be supplied to the customers especially using precised facilities. In this paper, the configuration of the weather information system and its application to the power system operation are generally introduced. And also, a method with test result is presented to find the suitable radar coverage area including the condition of electromagnetic wave shut off.

  • PDF

AR Model and LSQ Based Compensation Method for the Saturated Secondary Current of a Current Transformer (AR 모델 및 LSQ 기반 변류기 2차 전류 복원 기법)

  • Chang, Soo-Young;Lee, Dong-Gyu;Kang, Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.6
    • /
    • pp.221-226
    • /
    • 2006
  • The current flowing though a power line is measured by a current transformer (CT). Since a CT is a kind of transformer, saturation of magnetic flux in the core may occur when a large primary current flows. This saturation makes the secondary current of a CT distorted and causes problems in the protection point of view. Because of the current distortion, a protection relay cannot collect the correct information showing how the primary power system changed. Consequently, the current distortion may cause the mal-operation or operation time delay of protective relay. In this paper, an algorithm based on AR model and LSQ is proposed to compensate the saturated CT secondary currents. Various test results indicate that the proposed algorithm can accurately compensate a severely distorted secondary current and is not affected by remanence.