• 제목/요약/키워드: operating unit

검색결과 1,236건 처리시간 0.033초

종합병원의 수술유니트 계획에 관한 연구 (A study on the Architectural Planning of Operating-Unit in General Hospital)

  • 채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제7권1호
    • /
    • pp.77-84
    • /
    • 2001
  • This study provide the planning guidelines for the existing and the new alternative. On the bases of survey and analysis, the basic data for OP-Unit have been proposed in consideration of the development of medical science and hygiene, economic conditions during the last twenty years in Germany. The results of the study were firstly, genera1 basic data, secondly, guidelines of the architectural design for OP-Unit und rooms, thirdly, new alternative OP-Unit with 2 and 3 operation rooms.

  • PDF

GUI를 이용한 컴퓨터 Power Supply 내장형 UPS 시스템의 개발 (Development of UPS System Embedded in Computer Power Supply Using GUI)

  • 노인배;박지호;황기현;김동완;우정인
    • 전기학회논문지P
    • /
    • 제53권4호
    • /
    • pp.190-194
    • /
    • 2004
  • In this paper, UPS, which is embedded in computer power supply, is developed against the poor utility power system. In the developed system, PIC16C54 is used as the main controller, and UPS system consists of micom control module, power failure detecting module, charging module, power module, synchronous transfer module, and GUI module. Additionally, GUI module consists of battery charging state unit, power operating unit and operating state unit. The effectiveness of the developed system has been verified by the experimental results.

An Improved Dynamic Programming Approach to Economic Power Dispatch with Generator Constraints and Transmission Losses

  • Balamurugan, R.;Subramanian, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.320-330
    • /
    • 2008
  • This paper presents an improved dynamic programming (IDP) approach to solve the economic power dispatch problem including transmission losses in power systems. A detailed mathematical derivation of recursive dynamic programming approach for the economic power dispatch problem with transmission losses is presented. The transmission losses are augmented with the objective function using price factor. The generalized expression for optimal scheduling of thermal generating units derived in this article can be implemented for the solution of the economic power dispatch problem of a large-scale system. Six-unit, fifteen-unit, and forty-unit sample systems with non-linear characteristics of the generator, such as ramp-rate limits and prohibited operating zones are considered to illustrate the effectiveness of the proposed method. The proposed method results have been compared with the results of genetic algorithm and particle swarm optimization methods reported in the literature. Test results show that the proposed IDP approach can obtain a higher quality solution with better performance.

고전압 소스를 위한 모듈식 병렬운전 알고리즘 (Module Type Parallel Driving Algorithm for High Voltage Direct-Current source)

  • 우병국;이용화;강찬호;조관열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2008
  • For high voltage DC-DC converters, the parallel operation of several high voltage source modules is necessary to reduce the material cost. In the conventional parallel operation with HDC module control unit, it is difficult to repair the HDC system for the failure of control unit. To overcome these problems, new parallel operating algorithm for high voltage DC-DC converter is presented. The proposed algorithm has no main control unit and each module can be selected as the master according to the operating conditions. Therefore, one of modules can be replaced as the master immediately when the previous master module is failed. In addition, the extension of extra modules can be simple.

  • PDF

마이컴과 GUI를 이용한 컴퓨터 내장형 UPS의 개발 (Development of UPS Embedded in Computer using Micom and GUI)

  • 김동완;박지호;황기현;우정인;정영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2288-2291
    • /
    • 2004
  • In this paper, UPS, which is embedded in computer, is developed against the poor utility power system. In the developed system, PIC16C74A is used as the main controller, and UPS system consists of micom control module, power failure detecting module, charging module, power module, synchronous transfer module, and GUI module. Additionally, GUI module consists of battery charging state unit, power operating unit and operating state unit.

  • PDF

작업조건에 따른 공작기계의 열변형 특성 해석 보정 (Characteristics Analysis and Compensation of Thermal Deformation for Machine Tools with respect to Operating Conditions)

  • 이재종;최대봉;박현구;곽성조
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.70-75
    • /
    • 2001
  • In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindel unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball arti-fact, and five gap sensors. In order to analyze the thermal characteristics under several operating conditions, experiments performed with the touch probe unit and five gap sensors on the vertical and horizontal machining centers.

  • PDF

작업조건에 따른 공작기계의 열변형 특성 해석 (Characteristics Analysis of Thermal Deformation for Machine Tools with respect to Operating Conditions)

  • 이재종;최대봉;박현구;곽성조;박홍석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.449-453
    • /
    • 2000
  • In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to analyze the thermal characteristics under several operating conditions, experiments performed with the touch probe unit and five gap sensors on the vertical and horizontal machining centers.

  • PDF

무상수리 정책에서 응급수리 적용의 비용분석 모델 (Cost Analysis Model for Minimal Repair in Free-Replacement Policy)

  • 김재중;김원중
    • 산업경영시스템학회지
    • /
    • 제20권43호
    • /
    • pp.241-247
    • /
    • 1997
  • This paper is concerned with cost analysis model in free-replacement policy. The free-replacement policy with minimal repair is considered as follows; in a manufacturer's view point operating unit is periodically replaced, if a failure occurs between minimal repair and periodic maintenance time, unit is remained in a failure condition. Also unit undergoes minimal repair at failures in minimal-repair interval. Then total expected cost is calculated according to the parameter of failure distribution in a view of consumer's. The expected costs are included repair cost and usage cost: operating, fixed, minimal repair and loss cost. Numerical example is shown in which failure time of item has weibull distribution.

  • PDF

일 종합전문요양기관 간호사의 핵심역량 도출 및 근무지 특성별 중요도 인식 비교 (Defining the Core Competencies of the Nurses in A Tertiary Hospital and Comparing Different Units based on Their Respective Characteristics)

  • 성영희;정정희
    • 간호행정학회지
    • /
    • 제12권1호
    • /
    • pp.76-93
    • /
    • 2006
  • Purpose: The purpose of this study was to define the core components required of nurses to provide quality nursing care to patients and analyze the significance of these components in the hospital's various units to maintain a high level of competence among nurses. Method: The study evaluated 3 categories included 35 subcategories with 148 core components that were derived from literature review and interviews of nursing professionals. The nursing professional category included 18 subcategories with 98 components, the organizational culture category included 4 subcategories with 16 components, and the temperament-attitude category included 13 subcategories with 34 components. The study included 335 nurses with more than one year of hospital experience and measured disparities among different hospital units. The data was analyzed with SPSS-Win 10.0, differing perceptions of the importance of general traits among the participants were measured using standard deviation, and differing perceptions of the importance of professional traits among the participants were assessed using ANOVA and subsequently with the Bonferroni Test. The reliability of the aforementioned research tools were evaluated using the Cronbach's ${\alpha}$. Result: The results of the study were as follows: 1. Among the three categories, temperament-attitude category was perceived to be the most important, followed by nursing professional category and organizational culture category. Among the ten most important subcategories within the three categories, safety and infection prevention as well as responsibility were perceived to be the most important, followed by promotion of physiologic adaptation, document management and presentation, self-control, ethics, observance law, coping with emergency, humanity, and medication. 2. The relative importance of category associated with the core competencies within the hospital unit were as follows : 1) The units that rated nursing professional category as being the most significant were: internal medicine, surgical unit, mother-child unit, emergency room, intensive care unit, and operating room, in that order. 2) The units that rated the organizational culture competencies as being the most significant were: mother-child unit, internal medicine, surgical unit, emergency room, operating room, and intensive care unit, in that order. 3) The units that rated temperament-attitude category as being the most significant were: internal medicine, surgical unit, emergency room, mother-child unit, operating room, and intensive care unit, in that order.

  • PDF

정기보전 제도에서 응급수리를 고려한 대체품 수리정책에서의 비용분석 모델 (Cost Analysis Model with Minimal Repair of Spare Unit Repair Policy under Periodic Maintenance Policy)

  • 김재중
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제6권2호
    • /
    • pp.151-161
    • /
    • 2006
  • This article is concerned with cost analysis model in periodic maintenance policy. The repair policy is differently applied according as unit importance during an item being used and unit restoration during an item being failed. So in this paper the repair policy with minimal repair is considered as follow : as the occurrence of failure between minimal repair and periodic interval time, unit is replaced by a spare unit until the periodic maintenance time arrived. Then total expected cost per unit time is calculated according to scale parameter of failure distribution in a view of customer's. The total expected costs are included repair and usage cost : operating, fixed, minimal repair, periodic maintenance and spare unit cost. Numerical example is shown in which failure time of item has Erlang distribution.

  • PDF