• Title/Summary/Keyword: operating unit

Search Result 1,247, Processing Time 0.026 seconds

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

Characteristics of Korean Coastal Fisheries (한국 연안어업의 실태)

  • Yoon, Sang Chul;Jeong, Yeon Kyu;Zhang, Chang Ik;Yang, Jae Hyeong;Choi, Kwang Ho;Lee, Dong Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.6
    • /
    • pp.1037-1054
    • /
    • 2014
  • In this study, the status of coastal fisheries was examined based on the catch and number of fishing vessels of coastal fisheries in Korea. Comparing the status on coastal fisheries of the East Sea, Yellow Sea and South Sea in Korea, scientific evidence was made for fisheries management on coastal fisheries based on characteristics of each sea area. From 1990 to 2011, the catch of coastal fisheries in Korean waters ranged from 150,000 mt to 230,000 mt, with an average of 190,000 mt, and it accounted for 15% in average of total catch fished in adjacent waters of Korea. In order of catch by coastal fisheries, gillnet (36.7%) was the primary fishery, followed by coastal complex (24.7%), stow net (18.3%), trap (12.9%), lift net (3.9%), purse seine (3.0%) and beam trawl (0.4%) fisheries. In order of catch by species, anchovy (15.0%) had the largest proportion of total catch, followed by common squid (10.3%), akiami paste shrimp (5.2%), blue crab (3.9%) and octopus (3.7%). Of the average catch by sea area from 1990 to 2011, Yellow Sea, South Sea and East Sea were 37.4%, 34.6% and 28.0%, respectively. Since 2000s, however, the average catch of South Sea has accounted for the largest proportion. The number of permitted fishing vessels involved in 8 coastal fisheries was 55,336 vessels in average from 1997 to 2011. The number of vessels was about 47,000 vessels in 1997, and increased to 61,300 vessels until 2000, then has decreased to 44,000 vessels operating in 2011. In order of the number of permitted fishing vessels by fisheries, complex (52.4%) took the first place, followed by gillnet (31.5%), trap (13.4%), stow net (0.8%), beam trawl (0.8%), purse seine (0.6%), lift net (0.4%) and seine net (0.0%). In order of the number of permitted fishing vessels by sea area, South Sea (29,994 vessels) took the first place, followed by Yellow Sea (18,185 vessels) and East Sea (7,158 vessels). In order of the catch per unit effort (CPUE, mt/vessels) which was analyzed using catch and number of vessels in average by fishery, stow net is the highest followed by lift net, trap, purse seine, gill net, beam trawl and complex fisheries. In particular, the CPUE of complex and gill net fisheries, which accounted for the largest number of vessels were 4.0 mt/vessels and 1.6 mt/vessels, respectively. Since those are too low relative to other fisheries, it was judged to need systematical management on both fisheries.

Standardization of the Lease Fee Assessment System of Busan Port Container Terminals (부산항 컨테이너부두 임대료 산정체계 표준화 방안)

  • Kil, Kwang-Soo
    • Journal of Korea Port Economic Association
    • /
    • v.27 no.3
    • /
    • pp.65-90
    • /
    • 2011
  • Private stevedoring companies are leasing and operating the container terminals of the Busan Port. The total amount of lease fees private stevedoring companies paid in 2010 reached 161 billion wons, an approximately 66 percent of the total revenue of the Busan Port Authority(BPA). In other words, lease fees are the most important revenue source for BPA. However, the lease fee assessment system of Busan container terminals goes against the principle of equity due to different assessment methods and criteria adopted by each container terminal. Therefore, the purpose of the study is to analyze the systematic problems of the lease fee assessment system that is used at Busan container terminals, and propose a new standardized scheme with a case study on the new system. In order to standardize the assessment system, the assessment methods need to be simplified by using the Discounted Cash Flow(DCF) method. In addition, the assessment criteria such as assessment duration, discount rates, price indexes, estimated container throughputs, sales unit price per TEU, operation costs, including labor costs, need to be standardized as well. The new standardized assessment system can be applied to estimate lease fees for new terminals. However, for existing terminals to run the new system, factors such as assessment duration, discount rates, price indexes, estimated container throughputs, investment and re-investment costs, and maintenance & repair costs of the new system should be changed slightly.

A Study on Economic Impact Analysis of REITs Distribution Industry (리츠 유통산업의 경제적 파급효과에 관한 연구)

  • Choi, Cha-Soon
    • Journal of Distribution Science
    • /
    • v.13 no.12
    • /
    • pp.85-94
    • /
    • 2015
  • Purpose - The purpose of this paper is to provide a political registration point for analyzing the economic impacts on the national economy from the REITs distribution industry in our country. The REITs distribution industry was introduced in 2001 to accelerate the corporate restructuring process and advance the real estate market. During its establishment, the REITs distribution industry faced difficulties; however, the industry grew rapidly through interest from institutional investors, thus mitigating the establishment problems by 2006. In Korea, more than 108 REITs were operating as of the end of June 2015. REITs contribute significantly to the national economy. The economic impacts on the national economy of the REITs distribution industry was analyzed using input-output (I-O) analysis with respect to production, imports, value-added, and employment. Research design, data, and methodology - The research used an I-O analysis of the activities of the REITs distribution industry in the national economy. The I-O analysis methodology analyzes the economic effects that influence other industries with respect to one unit of external investment. The data for this analysis were the I-O table of 2013 as published by the Bank of Korea in 2014. Results - The findings of this study are as follows. First, if an external input to the REITs distribution industry is 1 won, the overall impact of the product is 1.3869 won, the import induction is 0.0002 won, and the value-added induction is 0.7656 won. A new investment of 659.9 billion won into the REITs industry was estimated to produce a gross effect of 915.2 billion won. Second, if an external input to the REITs distribution industry is 1 billion won, the employment-inducing effects are estimated at 19.6394 individuals. The employment-inducing coefficient of 19.6394 for the REITs distribution industry indicates that the industry created significant employment-more than other industries-because the coefficient was 2.2 times the 2013 industry average employment-inducing coefficient of 8.8. Third, the investment effects of the REITs distribution industry on production induction, value-added induction, and employment induction are assumed to be large in business support services, financing, communications and broadcasting, and professional, scientific, and technical services. Conclusions - The REITs distribution industry was analyzed as having a strong employment inducing, high value added effect. The REITs distribution industry is an excellent alternative for the government authority to create multilateral jobs. Because the REITs distribution industry has a significant positive impact on the national economy, it should be developed. However, the I-O methodology has restrictions with respect to the fixation and timing of the input coefficient. Follow-up research is expected to supplement the analysis method at a specific point in time.

Real-time Feedback Vibration Control of Structures Using Wireless Acceleration Sensor System - System Design and Basic Performance Evaluation - (무선 가속도센서 시스템을 이용한 건축물의 실시간 피드백 진동제어 - 시스템 구축 및 기초성능 평가 -)

  • Jeon, Joon Ryong;Park, Ki Tae;Lee, Chin Ok;Heo, Gwang Hee;Lee, Woo Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.21-32
    • /
    • 2013
  • This is a preliminary study for the real-time feedback vibration control of building structures. The study developed a wireless acceleration sensor system based on authentic technology capacities, to integrate with the Prototype AMD system and ultimately construct the feedback vibration control system. These systems were used to evaluate the basic performance levels of the control systems within model building structures. For this purpose, the study first developed a wireless acceleration sensor unit that integrates an MEMS sensor device and bluetooth communication module. Also, the study developed an operating program that enables control output based on real-time acceleration response measurement and control law. Furthermore, the Prototype AMD and motor driver system were constructed to be maneuvered by the AC servo-motor. Eventually, all these compositions were used to evaluate the real-time feedback vibration control system of a 2-story model building, and qualitatively measure the extent of vibrational reduction of the target structure within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within 1st and 2nd resonance frequency as well as the random frequency of the model building structure. Ultimately, this study confirmed the potential of its wireless acceleration sensor system and AMD system as an effective tool that can be applied to the active vibration control of other structures.

Research on Communication and The Operating of Server System for Vehicle Diagnosis and Monitoring (차량진단 및 모니터링을 위한 통신과 서버시스템 운용에 관한 연구)

  • Ryoo, Hee-Soo;Won, Yong-Gwan;Park, Kwon-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.6
    • /
    • pp.41-50
    • /
    • 2011
  • This article is concerned with the technology to provide car driver the car's status which are composed of car trouble code in car engine and many sensors. In addition, it installs vehicle diagnostic programs on wireless communication's portable device, for example, Smart phone, PDA, PMP, UMPC. As a result, this is to provide car manager with many information of car sensors when we go to car maintenance. it can monitor relevant information on vehicle by portable device in real time, alert drivers with specific messages and also enable them to address abnormalities immediately. Moreover, the technology could help the drivers who perhaps don't know very well about their vehicles to drive safely and economically as well; the reason is because the whole system is composed of just Vehicle-information collecting device and personal wireless communication's portables and transfers the relating data to server computers through wireless network in order to handle information on vehicles. This technology make us monitor vehicle's running, failure and disorder by using wireless communication's portable device. Finally, this study system is composed of a lot of application to display us the car's status which get car's inner sensor information while driving a car.

The Study of Modified Sequencing Batch Reactor Process for Small Advanced Wastewater Treatment (소규모 고도하수처리를 위한 변형 연속회분식공정에 관한 연구)

  • Han, Woonwoo;Kim, Kyuhyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • This study was carried out to estimate the performance of modified sequencing batch reactor (SBR) process by the application of SBR process for small advanced wastewater treatment plant. Organic, nitrogen and phosphorus were able to remove in the unit reactor by SBR process and it would be able to select the suitable operation method. The plant was operated to achieve high performance with influent control, optimum anoxic/oxic condition using intermediate aeration method, and solid (sludge) /liquid (effluent) separation by modified decanter. The optimum operating mode was 3Cycles a day and intermediate input and aeration. Under these conditions, the treatment efficiencies were good with 60% of designed flow rate and low influent quality. When the influent concentrations of BOD and CODMn were 120.4 mg/L and 95.7 mg/L, respectively. The effluent concentrations of BOD and CODMn were 6.8 mg/L and 11.0 mg/L, respectively. The average removal efficiencies of BOD and CODMn were 94.4% and 88.5%, respectively. The removal efficiencies of T-N and T-P were 69.6% and 73.6%, respectively when the average T-N and T-P concentrations were 32.2mg/L and 4.65mg/L, respectively. The T-N and T-P removal efficiencies were slightly decreased to 58.8% and 68.5%, respectively in the winter season but its were also stable efficiencies. BOD, T-N and T-P were removed by 90%. 67% and 46% respectively in the first anoxic/oxic condition, in addition to T-P was removed by 70% in the second anoxic/oxic condition. From the results, modified sequencing batch reactor (SBR) process is suitable for small advanced wastewater treatment.

  • PDF

Comparison of 3D Volumetric Subtraction Technique and 2D Dynamic Contrast Enhancement Technique in the Evaluation of Contrast Enhancement for Diagnosing Cushing's Disease

  • Park, Yae Won;Kim, Ha Yan;Lee, Ho-Joon;Kim, Se Hoon;Kim, Sun-Ho;Ahn, Sung Soo;Kim, Jinna;Lee, Seung-Koo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.102-109
    • /
    • 2018
  • Purpose: The purpose of this study is to compare the performance of the T1 3D subtraction technique and the conventional 2D dynamic contrast enhancement (DCE) technique in diagnosing Cushing's disease. Materials and Methods: Twelve patients with clinically and biochemically proven Cushing's disease were included in the study. In addition, 23 patients with a Rathke's cleft cyst (RCC) diagnosed on an MRI with normal pituitary hormone levels were included as a control, to prevent non-blinded positive results. Postcontrast T1 3D fast spin echo (FSE) images were acquired after DCE images in 3T MRI and image subtraction of pre- and postcontrast T1 3D FSE images were performed. Inter-observer agreement, interpretation time, multiobserver receiver operating characteristic (ROC), and net benefit analyses were performed to compare 2D DCE and T1 3D subtraction techniques. Results: Inter-observer agreement for a visual scale of contrast enhancement was poor in DCE (${\kappa}=0.57$) and good in T1 3D subtraction images (${\kappa}=0.75$). The time taken for determining contrast-enhancement in pituitary lesions was significantly shorter in the T1 3D subtraction images compared to the DCE sequence (P < 0.05). ROC values demonstrated increased reader confidence range with T1 3D subtraction images (95% confidence interval [CI]: 0.94-1.00) compared with DCE (95% CI: 0.70-0.92) (P < 0.01). The net benefit effect of T1 3D subtraction images over DCE was 0.34 (95% CI: 0.12-0.56). For Cushing's disease, both reviewers misclassified one case as a nonenhancing lesion on the DCE images, while no cases were misclassified on T1 3D subtraction images. Conclusion: The T1 3D subtraction technique shows superior performance for determining the presence of enhancement on pituitary lesions compared with conventional DCE techniques, which may aid in diagnosing Cushing's disease.

A Study on the Optimal Concession Contract Decision Model between Port Authority and Terminal Operators (항만공사와 터미널운영사간 최적임대계약 결정에 관한 모형)

  • Ashurov, Abdulaziz;Kim, Jae-Bong
    • Journal of Korea Port Economic Association
    • /
    • v.35 no.3
    • /
    • pp.1-18
    • /
    • 2019
  • The competition between port authorities (PAs) and terminal operating companies (TOCs) in providing port logistics services has gained importance. The PAs enter into leasing contracts with TOCs in various ways. This study aims to model a contract method that maximizes the joint profit between a PA and a TOC. Particularly, this study aims to model the equilibrium by comparing four types of contract schemes in the non-coordination, cooperation, Cournot, and collusion models. The results of the analysis show that the two-part tariff scheme generates a higher joint profit than the fixed and fee contracts. It is understood that risk- and profit-sharing between the PAs and TOCs helps the latter to maximize the throughput and the joint profit. These results are expected to provide an important theoretical basis for decision-making about port rent and freight between the PAs and TOCs.

Characteristics of Male Diploma Nursing Students in Korea (전국 간호전문대학 남학생의 제특성에 관한 조사연구)

  • 김혜성
    • Journal of Korean Academy of Nursing
    • /
    • v.9 no.2
    • /
    • pp.63-72
    • /
    • 1979
  • This study was performed to investigated of characteristics of male diploma nursing students. Data were collected by means of a mailed questionnaire. The sample included 29 respondents from 3 diploma nursing colleges during the period of Nov. 1st-15th, 1978. Major findings included. 1 ) Motive by which the objects of this investigation have chosen the science of nursing. Twenty-one (72.4%) responded, “As nursing occupation is a public welfare work, ”the highest rate, eighteen (62.3%) chose on advices of their parents and acquaintances. Seventeen (58.6%) reflected as a means of life with an occupation in hope of employment abroad. 2) Appreciation of nursing occupation. Twenty-two (75.9%) of opinions that the nursing job is called for by society was pre-dominent. While eighteen (62.1%) replied, “It is the job fit for the male sex, too.”“It is admitted as specialized occupation.”, or“It needs various human relation.”3) Degree of satisfaction wilt the science of nursing. Fifteen (51.7%) responded neither satisfied nor dissatisfied, while eight (27.6%) indicated as “satisfied”and four (13.8%) as“dissatisfied.”4) Degree of satisfaction with the faculty. Sixteen (55.2%) replied, “common, ”the highest, while ten (34.5%) indicated as“dissatisfied, ”two (6.9%) as“satisfied.”The reason for dissatisfaction with the faculty; The responses regarding dissatisfaction was twenty-three (79.3%) as insufficiency of the faculty. Thirteen (44.8%) indicated“the lack of personal cultivation of the faculty.”, And eleven (37.9%) indicated as“the quantitive shortage of the faculty, ”or“the vagueness of learning estimation.”5) Degree of satisfaction with the clinical, training. Eight (27.6%) responded as“common, ”or “dissatisfied, ”while seven (24.1%) indicated as“satisfied.”Reason for dissatisfaction with the training ; Twenty (69.0%) indicated“deficiency of personal treatment to the students of the men of business in the hospital”with respect to the reason, eighteen (62.1%) was indicated as gap between theory and practice, while eleven (37.9%) indicated“insufficiency of the equipment and materials of the hospital.”6) Interest in employment after graduation. Twenty-five (86.2%) indicated“going abroad”while fifteen (51.7%) indicated “education of nursing, ”which were the highest responses. Thirteen (44.8%) chose“Community Health Nursing (Health Center, Industrial Health).”7) Interest an employment during clinical nursing. Sixteen (55.2%) was interested in an operating room or the department of anesthesia, while fifteen (51.7%) was indicated “psychiatry, ”Eight (21.6%) chose a intensive care unit or a emergency room.

  • PDF