• Title/Summary/Keyword: operating room

Search Result 769, Processing Time 0.025 seconds

A Study on the Current Situation of Using Community Facilities and Its Proper Size in Apartment (아파트 단지 내 커뮤니티 시설의 이용실태 및 적정규모에 관한 연구)

  • Sohn, Sei-Kwan;Kim, Won-Kyung
    • Journal of the Korean housing association
    • /
    • v.20 no.6
    • /
    • pp.145-155
    • /
    • 2009
  • The purpose of this study is to examine the awareness of apartment residents on their using tendency of community facilities established in apartment complex in order to verify a role that such facilities play in making contributions to lives of apartment dwellers and to analyze their using tendency of the facilities and subsequent problems. The study produced the important findings as follows. First, the level of exchange among residents and their satisfaction were raised high in the apartment complex that offered substantial community facilities. Second, in regard to physical aspect, community activities among dwellers were brisk in the apartment complex where community facilities were organically connected. Third, fitness center, shower room and golf course were excessive in terms of space provided while the space alloted for G.X room, a place used exclusively for class, was insufficient. Fourth, the analysis of using tendency and preference level showed that fitness center, shower room and G.X room were the required facilities. The rooms for using PCs and watching DVDs and the singing room were found to be unnecessary because such facilities were low in the effectiveness when the operating cost was considered.

A Study on Operation Problems for the Emergency Medical Process Using Real-Time Data (실시간데이터를 활용한 응급의료 프로세스 운영에 관한 연구)

  • Kim, Daebeom
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.3
    • /
    • pp.125-139
    • /
    • 2017
  • Recently, interest in improving the quality of EMS(emergency medical services) has been increasing. Much effort is being made to innovate the EMS process. The rapid progress of ICT technology has accelerated the automation or intelligence of EMS processes. This study suggests an emergency room management method based on real-time data considering resource utilization optimization, minimization of human error and enhancement of predictability of medical care. Emergency room operation indices - Emergency care index, Short stay index, Human error inducing index, Waiting patience index - are developed. And emergency room operation rules based on these indices are presented. Simulation was performed on a virtual emergency room to verify the effectiveness of the proposed operating rule. Simulation results showed excellent performance in terms of length of stay.

Thermal Stress Evaluation by Elastic-Creep Analysis during Start-up of Boiler Header (보일러 헤더 기동시의 탄성 크리프 해석에 의한 열응력 평가)

  • Shin, Kyu-In;Yoon, Kee-Bong
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.17-22
    • /
    • 2009
  • Thermal stress and elastic creeping stress analysis was conducted by finite element method to simulate start-up process of a boiler header of 500MW standard fossil power plant. Start-up temperature and operating pressure history were simplified from the real field data and they were used for the thermal stress analysis. Two kinds of thermal stress analysis were considered. In the first case only temperature increase was considered and in the second case both of temperature and operating pressure histories were considered. In the first analysis peak stress was occurred during the temperature increase from the room temperature. Hence cracking or fracture may occur at the temperature far below the operating maximum temperature. In the results of the second analysis von Mises stress appeared to be higher after the second temperature increase. This is due to internal pressure increase not due to the thermal stress. When the stress components of radial(r), hoop($\theta$) and longitudinal(z) stress were investigated, compression hoop stress was occurred at inner surface of the stub tube when the temperature increased from room temperature to elevated temperature. Then it was changed to tension hoop stress and increased because of the operating pressure. It was expected that frequent start-up and shut-down operations could cause thermal fatigue damage and cracking at the stub tube hole in the header. Elastic-creeping analysis was also carried out to investigate the stress relaxation due to creep and stabilized stress after considerable elapsed time. The results could be used for assessing the creep damage and the residual life of the boiler header during the long-tenn service.

Measuring Situation Awareness of Operating Team in Different Main Control Room Environments of Nuclear Power Plants

  • Lee, Seung Woo;Kim, Ar Ryum;Park, Jinkyun;Kang, Hyun Gook;Seong, Poong Hyun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.153-163
    • /
    • 2016
  • Environments in nuclear power plants (NPPs) are changing as the design of instrumentation and control systems for NPPs is rapidly moving toward fully digital instrumentation and control, and modern computer techniques are gradually introduced into main control rooms (MCRs). Within the context of these environmental changes, the level of performance of operators in a digital MCR is a major concern. Situation awareness (SA), which is used within human factors research to explain to what extent operators of safety-critical systems know what is transpiring in the system and the environment, is considered a prerequisite factor to guarantee the safe operation of NPPs. However, the safe operation of NPPs can be guaranteed through a team effort. In this regard, the operating team's SA in a conventional and digital MCR should be measured in order to assess whether the new design features implemented in a digital MCR affect this parameter. This paper explains the team SA measurement method used in this study and the results of applying this measurement method to operating teams in different MCR environments. The paper also discusses several empirical lessons learned from the results.

Experimental study of water membrane sprinkler in fire prevention block (방화구획과 수막설비 관한 연구)

  • Oh, Chang-Hui;Son, Jang-Yeol;Kim, Hwa-Jung;Kim, Sang-Uk;Choi, Jin
    • Fire Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.3-9
    • /
    • 1988
  • This paper is study about establishment with water membrane sprinkler in fire prevention block of special Building. The testing program was directed toward investigating the temperature of fire and adjacent room. The results of fire test indicated that under the test conditions in this study, adjacent room temperature is very low in compare with fire room temperature at operating of water membrane sprinkler. Therefore, if exclusion of smoking can be soluted, substitution of water membrance sprinkler in fire resistance wall of fire prevention block is possible.

  • PDF

Fabrication of Ceramic Gas Sensors at Room Temperature and Characteristics (실온동작 세라믹 가스센서의 제작 및 특성)

  • Jung, Jae-Eop;Yoon, Yeu-Kyung;Lee, Sung-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.814-817
    • /
    • 2003
  • As additive Pt of a little to $SnO_2$ that gas sensing property is superior oxide-semiconductor material to fabricate gas sensor that operation is possible at room temperature and fabricated ceramic gas sensing devices. And, the change amount and sintering temperature of addition material investigated gas sensitivity by change of operation temperature, humidity relativity, Long-term stability and hysteresis. And achieved SEM and XRD analysis for characteristics searching examination of devices.

  • PDF

A Preliminary Study on the Communication Effect on Team Performance in Main Control Room of SMART

  • Heo, Eun Mee;Byun, Seong Nam
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.97-106
    • /
    • 2013
  • Objective: The aim of this study is to investigate the attributing factors influencing team performance. Background: Technically, it is necessary that operators adapt themselves to computerized and advanced techniques to operate the main control rooms safely in nuclear power plant in Korea. The more main control rooms are digitalized, the more important for operators to have high team performance it is. Method: This paper analyzes team process through literatures review and elicits team performance shaping factor. Especially, the objective of this research is to elicit communication using common team performance shaping factors. Results: This study has found communication through team performance shaping factors in Main Control Room of the SMART. Conclusion: This paper can offer a starting point for team communication, which can use team performance shaping factor framework that are emerging in these new nuclear power plant. Application: As a result, I expect that the evaluation communication for MCR operator's team performance will lead the operating techniques in nuclear power industry internationally.

Sensing performances of Semiconducting Carbon Nanomaterials based Gas Sensors Operating at Room Temperature (반도체 탄소 나노재료 기반 상온 동작용 가스센서)

  • Choi, Sun-Woo
    • Ceramist
    • /
    • v.22 no.1
    • /
    • pp.96-106
    • /
    • 2019
  • Semiconducting carbon-based nanomaterials including single-walled carbon nanotubes(SWCNTs), multi-walled CNT(MWCNTs), graphene(GR), graphene oxide(GO), and reduced graphene oxide(RGO), are very promising sensing materials due to their large surface area, high conductivity, and ability to operate at room temperature. Despite of these advantages, the semiconducting carbon-based nanomaterials intrinsically possess crucial disadvantages compared with semiconducting metal oxide nanomaterials, such as relatively low gas response, irreversible recovery, and poor selectivity. Therefore, in this paper, we introduce a variety of strategies to overcome these disadvantages and investigate principle parameters to improve gas sensing performances.

Estimation of Temperature Distribution in the Refrigerator-Room Using Fuzzy Adaptive Model (퍼지적응모델을 이용한 냉장실 온도분포 추정)

  • 김지관
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.46
    • /
    • pp.159-166
    • /
    • 1998
  • Estimating the temperature distribution of a refrigerator-room is important for preventing the over-refrigeration and improving its operating efficiency. It is also necessary in the realization process of the concentrated refrigeration function which has been provided recently as a generalized function in many refrigerator models. In this paper, we investigate the estimation problem of temperature in refrigerator-room and propose a fuzzy adaptive model. The model is unique in that it employs the concept of the fuzzy dead zone in order to improve the accuracy of estimation. The obtained results are then used for determining the optimal position of a temperature sensor.

  • PDF

Development of efficient smart library resource management system based on IoT (IoT 기반의 효율적인 스마트도서관 자원 관리 시스템 개발)

  • Lee, Joohwa;Lee, Myungsuk
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 2019
  • In this study, we constructed a system to operating and manage the resources of the Smart Library Reading Room automatically using the Internet of things. The persistent problem of smart library or unattended library is electric energy waste and efficient seat management. The electricity and seat layout management method of the existing library reading room is being treated as concentrated management in the central system. However, this approach results in wasting electricity and seats do not provide a fair opportunity for each user. In this study, IoT sensor was used to turn off electricity and empty seat for about 20 minutes, so that it could be marked as vacant and managed efficiently, so that opportunities for seats were evenly maintained. In the future, we will improve this and construct a model in the reading room of actual village library or school library, and analyze and reflect the result.