Relationship Between Humidity and Insulation Status of XLPE 6.6kV Cables for the Load of Electric Turbine Generator (터빈 발전기 부하용 XLPE 6.6kV 케이블의 절연층 절연상태와 습도의 상관관계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.185-190
    • /
    • 2016
  • The high-power 6.6 kV XLPE (or CV) cables at Korean electric power stations have been in operation for the last 40 years. Most of the XLPE cables starts deteriorating in 6-8 years from the operating instant of time, some cables may be breakdown at any moment even though they were installed in recent years, causing, huge socioeconomic losses. In order to prevent unexpected cable accident, the operating status of power cables should be monitored in regularly, timely bases. We have invented a device in order to systematically monitor and prevent an abrupt accidents of high-power cables in operation at power station. It has been installed at Korean Western Power Co. Ltd. at Taean, and operating normally for the last 4 years. In this paper, we introduce the functions and operating principles of the measuring device, and present the relationship between humidity and insulation status of XLPE cables for the load of electric turbine generator.

A Pulsed Mode Operating DC Power Supply Based on Modified Multilevel Converter (Modified 멀티레벨 컨버터 기반 펄스모드 동작 직류전원장치)

  • Ahn J.S.;Nho E.C.;Kim I.D.;Kim H.G.;Chun T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.264-268
    • /
    • 2003
  • This paper describes a high voltage high power DC power supply which has the ability of pulsed mode operation. The power supply Is constructed with several series connected power converters based on modified multilevel converters. The modified multilevel converters are suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis, simulations, and experiments are carried out to Investigate the operation and usefulness of the proposed scheme.

  • PDF

A Study on the Operation Characteristic of Induction Generator in the Small Hydropower Plant (소수력 발전소에 적용하는 유도발전기의 동작 특성)

  • Kim, Young-Kuk;Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.632-638
    • /
    • 2013
  • In this study, we described voltage fluctuation characteristics of distribution line during starting and normal operation condition of the small hydro generators. Based on these theories, we scrutinized the starting and operating characteristics of induction generators installed in two small hydro power plants that is connected to the distribution line and researched necessary factors when selecting the generator type. The type of turbines and capacity of generators are different. One is below 1,000kW and the other is above 1,000kW. Two generators are tested during starting, and it acts as motor not generator at the instant that the machine is connected to the grid. After connecting to the grid, the machine rotates above synchronous speed before converting to the generator mode. Therefore the characteristic of the generator during starting is same as it of motor.

A study on operating properties of superconducting fault current limiter in the line-to-line fault (선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

Operating properties of superconducting fault current limiters with a sing1e line-to-ground fault in a three-phase system (3상 전력계통의 1선 지락사고에 대한 초전도한류기의 동작특성)

  • 최효상;현옥배;김혜림;황시돌;차상도
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.261-262
    • /
    • 2003
  • We performed unsymmetrical analysis of a single line-to-ground fault in a three-phase system. The current limiting elements were meander type YBCO stripes coated with Au shunt. When the fault occurred, short circuit currents were effectively limited within 1-2 msec after fault instant. The unsymmetrical rate of fault phase was distributed from 6.4 to 1.4 and most of the fault current flowed in the grounding line due to its direct grounding system.

  • PDF

Analysis on Position Estimation Performance according to Injection Frequency in Carrier-Based Sensorless Operation (반송파 기반 센서리스 운전에서 주입하는 신호의 주파수에 따른 위치 추정 성능 분석)

  • Hwang, Chae-Eun;Lee, Younggi;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.139-146
    • /
    • 2018
  • This work puts forward a theoretical analysis on position estimation performance of interior permanent magnet synchronous motor (IPMSM) according to the injection frequency in carrier-based sensorless operation. The effects of spatial harmonics on inductance and voltage distortion due to the nonideal characteristics of IPMSM and inverter are examined as factors influencing the position estimation performance. Furthermore, the position estimation performance is analyzed by calculating the current at the switching instant in several operating conditions. In summary, the half switching frequency injection is more robust to the nonideal characteristics of IPMSM, especially with light load condition. The validity of the analysis is verified by the simulation and experimental results.

A Study on Friction Coefficient of Disk Brake Lining for Rolling Stock According to Disk Type (디스크 타입에 따른 철도차량용 디스크 브레이크 라이닝의 마찰계수 특성에 관한 연구)

  • Kwon Sung-Tae;Kim Won-Kyung;Kim Jeong-Guk;Yoon Sung-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.472-476
    • /
    • 2004
  • In this study, we investigate the change characteristic of friction coefficient of disk brake lining for rolling stock according to disk type, The actual brake tests were carried out under constant brake force and operating sequence by using dynamo-tester. Test results showed that instant friction coefficient was higher in the case of devided disk type rather than single body disk type, Also, averge friction coefficient was appeared similer to the above result. It is thought that ,in the case of devided disk type, friction resistance was increased due to the gap between both side of half disk.

  • PDF

Study of Back-Up Electric Power Source as a Role for Instant Power Industry Safety by Super Capacitor (순간 정전시 산업안전용 보조전원 역할의 Super Capacitor에 관한 연구)

  • 김상길;김종철;허진우;김경민;이용욱;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.345-354
    • /
    • 1999
  • A new type of capacitor named "Super Capacitor" has been developed, in which the properties of electric double layer formed at the interface of activated carbon electrode- liquid organic electrolyte is applied. This capacitor is small In size, light in weight, wide In temperature range(-25~$70^{\circ}C$), large in charge-discharge capability and good in voltage preservation. And this super capacitor is applied as a power back-up for electricity failure in volatile memory devices etc., a power source for a short time and a power source for operating actuators. At present the development of high power back-up types of the capacitor system and improvement of their characteristics are being actively conducted in order to find wider applications.lications.

  • PDF

Design of Port Plate in Gerotor Pump for Reduction of Pressure Pulsation

  • Kim Sang-Yeol;Nam Yun-Joo;Park Myeong-Kwan
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1626-1637
    • /
    • 2006
  • The pressure pulsation due to the gear geometry of the gerotor (generalized rotor) pump mainly occurs in an instant that the chamber of the gerotor enters the delivery port and leaves the suction one. Such a pressure pulsation may result in undesirable vibration and noise of pump components as well as cavitation in hydraulic system. Therefore, it is very important to examine the pressure characteristic of the gerotor pump at its design and analysis stages. In this paper, in order to reduce the pressure pulsation in the gerotor pump, the port plate with the relief grooves is designed by referring to as notch of vane pump and relief groove of piston pump. A series of the theoretical analyses on the pressure pulsation is performed in consideration of various design parameters of the port plate, including the installation positions of the port inlet/outlet and the groove width, and the operating conditions such as rotational velocity and delivery pressure.

Characteristics of Magnetic Field Generated by Operating Low Pressure Discharge Lamp (저압방전등의 사용중에 발생하는 자계특성)

  • 이복희;전덕규;길경석;백용현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.63-66
    • /
    • 1994
  • This paper describes the developed sensor for measuring the time-varying magnetic fields and presents the characteristics of the magnetic fields and presents the characteristics of the magnetic field generated by lighting a fluorescent lamp. The frequency bandwidth of magnetic field measurement system is kknown as 40 Hz∼100 kHz by means of calibration experiment. The magnetic field waveform which originates from the various lighting systems was measured and the frequency components were analyzed by fast Fourier transformation technique. The magnetic field generated during the operation of the fluorescent lamp mainly includes the odd harmonics, and in the case\ulcorner of push button switch and high frequency starter types the fast transient component is occurred in an instant of lighting.