• Title/Summary/Keyword: operating current

Search Result 3,357, Processing Time 0.031 seconds

Characterization of Nitrogen Gas Crossover in PEM Fuel Cell Stacks (고분자 연료전지 스택에서 질소 크로스오버 특성에 관한 연구)

  • Baik, Kyung-Don;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.3
    • /
    • pp.207-214
    • /
    • 2009
  • Crossover of nitrogen from cathode to anode is inevitable in typical membranes used in PEM fuel cells. This crossovered nitrogen normally accumulates in the hydrogen recirculation system at anode side channels. Excessive buildup of nitrogen in the anode side lowers the relative hydrogen concentration and finally affects the performance of fuel cell stack. So it is very important to analysis the nitrogen gas crossover at various operating conditions. In this study, characterization of nitrogen gas crossover in PEM fuel cell stack was investigated. The mass spectroscopy (MS) has been applied to measure the amount of the crossovered nitrogen gas at the anode exit. Results show that nitrogen gas crossover rate was affected by current density, anode and cathode stoichiometric ratio and operating pressure. Current density, anode stoichiometric ratio and anode operating pressure do not affect nitrogen crossover rate but anode exit concentration of nitrogen. Cathode pressure and stoichiometric ratio largely affect the nitrogen crossover rate.

Determination of Optimal Controlled Switching Instants for Circuit Breaker of Shunt Reactors (분로 리액터용 개폐제어 차단기의 최적 개폐시점 선정)

  • 이우영;박경엽;정진교;김희진
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.664-669
    • /
    • 2002
  • In this paper the method to determine tire optimal switching instants in order to reduce the transient surges during switching not relevant to the neutral treatment of shunt reactors is presented. This method consists of the following two steps. First, the instants of the voltage peaks between the contacts of each poles and the voltage magnitude as well as the moments of the current zero crosses were found out analytically. Next, the instants of the contact touches or separations were determined in consideration of the rate of decrease of dielectric strength or a circuit breaker and the variation of the its operating time. The results obtained from the EMTP(Electromagnetic Transient Program) analysis studies show that the making instants are established at the peak voltage of each three poles for any conditions of a neutral point and the possible upper limited values of inrush currents due to the variation of the mechanical operating time can be estimated.

Effect of Operating Parameters on the Removal Performance of Copper Ion by Electrodialysis (전기투석을 이용한 구리이온의 제거 시 운전인자의 영향)

  • Jung, Hyo-Sang;Lee, Gangchoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • To evaluate the feasibility of electrodialysis for copper removal from industrial wastewater, the effect of operating parameters on the removal of copper was experimentally estimated. The limiting current density (LCD) linearly increased with the copper concentration and the flow rate. The time when the copper concentration of diluate reaches to 3 mg/L was linearly proportional to initial concentration of diluate, and the concentration of concentrate did not affect the removal rate. Increase in the flow rate gave a positive effect on the removal rate and became insignificant at flow rates greater than 2.4 L/min. The removal rate increased with the applied voltage. From the operation of the electrodialysis module used in this research, the flow rate of 2.4 L/min and the voltage corresponding to the 80~90% of LCD were found be the optimum operating condition for the copper removal from highly concentrated copper solutions.

Investigation on vapor-cooled current leads operating in pulse mode (펄스 모드로 작동하는 증기냉각 전류 도입선에 관한 연구)

  • 인세환;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.66-72
    • /
    • 2002
  • This paper describes numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas (low and a copper lead and temperature dependent properties of helium gas, copper and stainless steel. This numerical modeling was compensated and validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor was suggested for the current leads under pulse operation through this modeling, which can significantly reduce heat input to a cryostat.

Operating Characteristics of Hybrid Type Superconducting Fault Current Limiter (하이브리드형 초전도 한류기의 동작 특성)

  • Cho, Yong-Sun;Nam, Gueng-Hyun;Lim, Sung-Hun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.6
    • /
    • pp.255-258
    • /
    • 2006
  • We investigated the operating characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the inductance of secondary windings. The hybrid type SFCL consists of a transformer that has a primary winding and a secondary winding with serially connected $YBa_2Cu_3O_7$ (YBCO) films. The resistive-type SFCL has difficulty when it comes to raising the capacity of the SFCL due to slight differences of critical current densities between units and structure of the SFCL. The hybrid-type SFCL with closed-loop is able to achieve capacity increase through the electrical isolation and reduction of the inductance of the secondary winding with a superconducting element of the same critical current. On the other hand, the current limiting characteristics were nearly identical in the hybrid-type SFCL with open-loop compared to closed-loop, but quench time was longer than the hybrid-type SFCL with closed-loop. We confirmed that the capacity of the SFCL was increased effectively by the reduced inductance of the secondary winding. In addition, the power burden of the system also could be lowered by reducing the inductance of secondary winding.

Diagnostic Techniques of Lightning Arresters for DC Electric Traction Vehicles (직류전동차용 피뢰기 진단기술)

  • Kil Gyung-Suk;Song Jae-Yong;Kim Il-Kwon;Moon Seung-Bo;Shin Gwang-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.357-361
    • /
    • 2006
  • This paper dealt with the performance evaluation and the diagnostic techniques of lightning arresters for DC electric traction vehicle. Field Measurements on the protective operation of lightning arresters against surge currents were carried out on running vehicles to acquire the data necessary for the diagnosis. The frequency and the magnitude of surge events were analyzed. Surge currents of $1\sim3$ times were recorded in one running service route and their magnitudes were ranges of $150A\sim2kA$. Also, an acceleration experiment on a lightning arrester by the standard lightning impulse current of 8/20 us and 5 kA was performed to know the aging characteristics. After the surge current application of 3,000 times, the reference voltage decreased by 4.5 %, and the leakage current was below 10 uA at the continuous operating voltage and about 50 uA at the rated voltage. From the experimental results, we propose a decision level of leakage current for the arrester used in this paper and designed an arrester tester which analyzes arrester condition by the magnitude of leakage current.

Characterization of oxygen plasma by using a langmuir probe in the inductively coupled plasma (정전 탐침을 이용한 유도 결합형 반응기에서 발생하는 산소 플라즈마의 특성연구)

  • 김종식;김곤호;정태훈;염근영;권광호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.428-435
    • /
    • 2000
  • Negative ion generation in an inductively coupled oxygen plasma was investigated by using a Langmuir probe. It was observed that the probe current ratio of the positive ion saturation current and the negative current which is consisted of the electron current and the negative ion current, and also the potential difference between the floating potential and plasma potential vary with the RF input power and more sensitively with the operating pressure, respectively. Results show that the operating condition to achieve the maximum probe current ratio and the minimum potential difference shift from the low pressure region to the high pressure regions with increasing the input power. It implies that the generation of the negative oxygen ions increases and the recombination of the positive and negative ions are enhanced in the plasma.

  • PDF

Transient Characteristics of a Transformer Type SFCL Applying the Superconductor and the Normal-conductor into the Secondary Winding (초전도체 및 상전도체의 변압기 2차측 적용에 따른 변압기형 SFCL 특성 비교)

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.873-877
    • /
    • 2016
  • This paper proposed the structure that applied superconductors to the neutral line of a transformer and applied the normal conductors to the third line. The superconductor applied to the neutral line of a transformer limited the peak value of initial fault current, while the normal conductor finally limited the fault current. In order to secure the operating reliability of transformer type Superconducting Fault Current Limiter (SFCL) of previously proposed structure, we analyzed the operating characteristics according to the fault types. We tested a line-to-ground fault and a line-to-line fault. As a result of the experiment, all the faults showed that the superconductor stably limited the peak-value of initial fault current. Also, the normal conductor finally limited the fault current. Based on this research results, We thought that if the structure of inserting superconductor into the neutral line is applied to the real system, it could improve the reliability and stability of the power system.

Analysis of three-phase current type PWM converter using resonant DC Link snubber (공진 DC 링크 스너버를 이용한 3상 전류형 PWM 컨버터의 해석)

  • Kim, Young-Mun;Kang, Wook-Jung;Mun, Sang-Pil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.2
    • /
    • pp.49-55
    • /
    • 2003
  • This paper presents a novel three-phase current-fed Pulse Width Modulation converter with switched capacitor type resonant DC link commutation circuit operating PWM pattern strategy under a design consideration of low-pass filter, which can operate on the basis of the principle of zero current soft switching commutation. In the first place, the steady state operating principle of this converter with a new resonant DC link snubber circuit is described in connection with the equivalent operation circuit, together with the practical design procedure of the switched-capacitor type resonant DC link circuit is discussed from a theoretical viewpoint on the basis of a design example for high-power applications. The actively delayed time correction method to compensate distorted currents due to a relatively long resonant commutation time is newly implemented in the open loop control scheme so as to acquire the new optimum PWM pattern. Finally, the experiment of set-up in laboratory system of this converter is concretely demonstrated herein to confirm a zero current soft-switching commutation of this converter. The comparative evaluations between current-fed hard switching PWM and soft-switching PWM converters are carried out from a viewpoint of their PWM converter characteristics.

Cost Analysis of Home Care with Activity-Based Costing(ABC) (활동기준원가계산[ABC]을 적용한 가정 간호 원가 분석)

  • Lee Su-Jeong
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.6
    • /
    • pp.1117-1128
    • /
    • 2004
  • Purpose: This study was carried out to substantiate the application process of activity-based costing on the current cost of hospital home care (HHC) service. The study materials were documents, 120 client charts, health insurance demand bills, salary of 215 HHC nurses, operating expense, 6 HHC agencies, and 31 HHC nurses. Method: The research was carried out by analyzing the HHC activities and then collecting labor and operating expenses. For resource drivers, HHC activity performance time and workload were studied. For activity drivers, the number of HHC activity performances and the activity number of visits were studied. Result: The HHC activities were classified into 70 activities. In resource, the labor cost was 245₩per minute, operating cost was 9,570₩ per visit and traffic expense was an average of 12,750₩. In resource drivers, education and training had the longest time of 67 minutes. Average length of performance for activities was 13.7 minutes. The workload was applied as a relative value. The average cost of HHC was 62,741₩ and the cost ranged from 55,560₩ to 74,016₩. Conclusion: The fixed base rate for a visit in the current HHC medical fee should be increased. Exclusion from the current fee structure or flexible operation of traveling expenses should be reviewed.