• Title/Summary/Keyword: operating current

Search Result 3,370, Processing Time 0.03 seconds

A Study on the Configuration of Pre-install Applications on Smartphone for Customer Needs (고객 중심의 스마트폰 선탑재 앱 구성방안에 관한 연구)

  • Yeon, Bo Huem;Kang, Won Young;Choi, Seong Jhin
    • Journal of Broadcast Engineering
    • /
    • v.24 no.1
    • /
    • pp.105-117
    • /
    • 2019
  • Current Android smartphones include about 25 to 35 essential applications(unerasable) related to function and operation of the android smartphone itself and about 30 optional applications(removable) provided by carriers, Google and manufacturers. These applications were not able to be removed until the announcement of the smartphone applications pre-install guide from the government in January 2014, so there were memory limitations in installing new applications, causing consumer complaints by consuming data during the auto-update process of the pre-installed applications. After the announcement, we were able to delete optional applications but the complaints about the data consumption still did not disappear. Therefore, in this paper, we carried out the customer survey and analyzed the behavior information such as how carriers are operating pre-installed applications and what kind of applications customer prefers and how many applications customer wants to be pre-installed. And we proposed how to configure pre-install applications on smartphone for customer needs.

Crack growth and cracking behavior of Alloy 600/182 and Alloy 690/152 welds in simulated PWR primary water

  • Lim, Yun Soo;Kim, Dong Jin;Kim, Sung Woo;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.228-237
    • /
    • 2019
  • The crack growth responses of as-received and as-welded Alloy 600/182 and Alloy 690/152 welds to constant loading were measured by a direct current potential drop method using compact tension specimens in primary water at $325^{\circ}C$ simulating the normal operating conditions of a nuclear power plant. The as-received Alloy 600 showed crack growth rates (CGRs) between $9.6{\times}10^{-9}mm/s$ and $3.8{\times}10^{-8}mm/s$, and the as-welded Alloy 182 had CGRs between $7.9{\times}10^{-8}mm/s$ and $7.5{\times}10^{-7}mm/s$ within the range of the applied loadings. These results indicate that Alloys 600 and 182 are susceptible to cracking. The average CGR of the as-welded Alloy 152 was found to be $2.8{\times}10^{-9}mm/s$. Therefore, Alloy 152 was proven to be highly resistant to cracking. The as-received Alloy 690 showed no crack growth even with an inhomogeneous banded microstructure. The cracking mode of Alloys 600 and 182 was an intergranular cracking; however, Alloy 152 was revealed to have a mixed (intergranular + transgranular) cracking mode. It appears that the Cr concentration and the microstructural features significantly affect the cracking resistance and the cracking behavior of Ni-base alloys in PWR primary water.

Diagnostic value of magnetic resonance imaging using superparamagnetic iron oxide for axillary node metastasis in patients with breast cancer: a meta-analysis

  • Lee, Ru Da;Park, Jung Gu;Ryu, Dong Won;Kim, Yoon Seok
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.297-306
    • /
    • 2018
  • Objectives: Identification of axillary metastases in breast cancer is important for staging disease and planning treatment, but current techniques are associated with a number of adverse events. This report evaluates the diagnostic accuracy of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging (MRI) techniques for identification of axillary metastases in breast cancer patients. Methods: We performed a meta-analysis of previous studies that compared SPIO enhanced MRI with histological diagnosis after surgery or biopsy. We searched PubMed, Ovid, Springer Link, and Cochrane library to identify studies reporting data for SPIO enhanced MRI for detection of axillary lymph node metastases in breast cancer until December 2013. The following keywords were used: "magnetic resonance imaging AND axilla" and "superparamagnetic iron oxide AND axilla". Eligible studies were those that compared SPIO enhanced MRI with histological diagnosis. Sensitivity and specificity were calculated for every study; summary receiver operating characteristic and subgroup analyses were done. Study quality and heterogeneity were also assessed. Results: There were 7 publications that met the criteria for inclusion in our meta-analysis. SROC curve analysis for per patient data showed an overall sensitivity of 0.83 (95% Confidence interval (CI): 0.75-0.89) and overall specificity of 0.97 (95% CI: 0.94-0.98). Overall weighted area under the curve was 0.9563. Conclusions: SPIO enhanced MRI showed a trend toward high diagnostic accuracy in detection of lymph node metastases for breast cancer. So, when the breast cancer patients has axillary metastases histologically, SPIO enhanced MRI may be effective diagnostic imaging modality for axillary metastases.

Exploring the Validity of Convergence between Qualifications and the Support System for Lifelong Education for the Disabled (자격과 장애인평생교육 지원체제 간 융합 타당성 탐구)

  • Kim, Young-Jun;Kwon, Ryang-Hee;Do, Myung-Ae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.82-91
    • /
    • 2021
  • The purpose of this study was to explore the prerequisites for securing the convergence validity of qualifications and the development of a lifelong education support system for the disabled. The research method consisted of the procedure of collecting and analyzing previous research literature and conducting expert meetings. The content of this study is based on the limitations and reflection of the current promotion of the qualification system for lifelong education professionals for the disabled, establishing the academic foundation and concept system for lifelong education for the disabled, designing a career development path for the professional competency of developing and operating the lifelong education curriculum for the disabled. Also, Restructuring of related institutions based on the curriculum for lifelong education for the disabled, and enhancement of qualification types for nurturing professionals for lifelong education for the disabled were suggested. As a result of the study, it was analyzed that the value and function of qualifications are very important in the comprehensive category of developing a lifelong education support system for persons with disabilities, and conclusively, the viewpoint of university foundation and the application model for nurturing professionals for lifelong education for persons with disabilities should be reviewed.

Development of A Model for Diagnosing Management Capabilities of Public Facility (공공시설물관리 역량 진단 모델 개발)

  • Sung, Yookyung;Yoo, Wi Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.6
    • /
    • pp.555-566
    • /
    • 2020
  • Recently, the aging of public facilities in Korea have accelerated, and the existing framework for facility management is shifting toward to facility asset management in terms of performance-based proactive control. Therefore, the operation of public facility involves both safety assurance from the deteriorated facilities and management capabilities for sustainable maintenance in the required valuation and level of service, such as valuation of facility assets, life-cycle management plans, financing, and so on. In this study, the Facility Asset Management Indicator(FAMI) has been developed for public facility asset management, and it provides the quantitative management grade, based on international standards, such as ISO 55000 series and International Infrastructure Management Manual(IIMM). The FMMI includes 10 key areas to apply a diagnosis model into management capabilities, 113 detailed elements, and 5 maturity grades. As the importance of public facility asset management is increasing constantly, this is expected to identify previously the strengths and weaknesses of public facility operating institutions. Eventually, they can obtain the effective ways to improve their own capabilities, minimize the public funds, establish the strategies for innovating the current management structures, and operate stably the facilities in the required performance.

Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir (회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가)

  • Maeng, Minsoo;Shahi, Nirmal Kumar;Kim, Donghyeun;Shin, Gwyam;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

Fabrication of Soft Textile Actuators Using NiTi Linear Shape Memory Alloy and Measurement of Dynamic Properties for a Smart Wearable (스마트 웨어러블용 NiTi계 선형 형상기억합금을 이용한 소프트 텍스타일 액추에이터 제작 및 동적 특성 측정)

  • Kim, Sang Un;Kim, Sang Jin;Kim, Jooyong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.6
    • /
    • pp.1154-1162
    • /
    • 2020
  • In this study, the soft textile actuator is produced for a smart wearable with the shape memory effects from linear shape memory alloys of Nickel and Titanium using the driving force through the fabrication process. The measurement model was designed to measure dynamic characteristics. The heating method, and memory shape of the linear shape memory alloy were set to measure the operating temperature. A shape memory alloy at 40.13℃, was used to heat the alloy with a power supply for the selective operation and rapid reaction speed. The required amount of current was obtained by calculating the amount of heat and (considering the prevention of overheating) set to 1.3 A. The fabrication process produced a soft textile actuator using a stitching technique for linear shape memory alloys at 0.5 mm intervals in the general fabric. The dynamic characteristics of linear shape memory alloys and actuators were measured and compared. For manufactured soft textile actuators, up to 0.8 N, twice the force of the single linear shape memory alloy, 0.38 N, and the response time was measured at 50 s.

Synergy study on charge transport dynamics in hybrid organic solar cell: Photocurrent mapping and performance analysis under local spectrum

  • Hong, Kai Jeat;Tan, Sin Tee;Chong, Kok-Keong;Lee, Hock Beng;Ginting, Riski Titian;Lim, Fang Sheng;Yap, Chi Chin;Tan, Chun Hui;Chang, Wei Sea;Jumali, Mohammad Hafizuddin Hj
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1564-1570
    • /
    • 2018
  • Charge transport dynamics in ZnO based inverted organic solar cell (IOSC) has been characterized with transient photocurrent spectroscopy and localised photocurrent mapping-atomic force microscopy. The value of maximum exciton generation rate was found to vary from $2.6{\times}10^{27}m^{-3}s^{-1}$ ($J_{sat}=79.7A\;m^{-2}$) to $2.9{\times}10^{27}m^{-3}s^{-1}$ ($J_{sat}=90.8A\;m^{-2}$) for devices with power conversion efficiency ranging from 2.03 to 2.51%. These results suggest that nanorods served as an excellent electron transporting layer that provides efficient charge transport and enhances IOSC device performance. The photovoltaic performance of OSCs with various growth times of ZnO nanorods have been analysed for a comparison between AM1.5G spectrum and local solar spectrum. The simulated PCE of all devices operating under local spectrum exhibited extensive improvement with the gain of 13.3-3.7% in which the ZnO nanorods grown at 15 min possess the highest PCE under local solar with the value of 2.82%.

Thermal stability, magnetic and magnetocaloric properties of Gd55Co35M10 (M = Si, Zr and Nb) melt-spun ribbons

  • Jiao, D.L.;Zhong, X.C.;Zhang, H.;Qiu, W.Q.;Liu, Z.W.;Ramanujan, R.V.
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1523-1527
    • /
    • 2018
  • The thermal stability, magnetic and magnetocaloric properties of $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) melts-pun ribbons were studied. The relatively high reduced glass transition temperature ($T_{x1}/T_m$ > 0.60) and low melting point ($T_m$) resulted in excellent glass forming ability (GFA). The Curie temperatures ($T_C$) of melt-spun amorphous ribbons $Gd_{55}Co_{35}M_{10}$ for M = Si, Zr and Nb were 166, 148 and 173 K, respectively. For a magnetic field change of 2 T, the values of maximum magnetic entropy change $(-{\Delta}S_M)^{max}$ for $Gd_{55}Co_{35}Si_{10}$, $Gd_{55}Co_{35}Zr_{10}$ and $Gd_{55}Co_{35}Nb_{10}$ were found to be 2.86, 4.28 and $4.05J\;kg^{-1}K^{-1}$, while the refrigeration capacity (RC) values were 154, 274 and $174J\;kg^{-1}$, respectively. The $RC_{FWHM}$ values of amorphous alloys $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) are comparable to or larger than that of $LaFe_{11.6}Si_{1.4}$ crystalline alloy. Large values of $(-{\Delta}S_M)^{max}$ and RC along with good thermal stability make $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) amorphous alloys be potential materials for magnetic cooling operating in a wide temperature range from 150 to 175 K, e.g., as part of a gas liquefaction process.

A Study on the Standardization of Information for the Integrated Management of Researcher's Information (연구자정보 통합관리를 위한 정보 표준화 연구)

  • Jang, Kiman;Kim, Eunsung;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.741-747
    • /
    • 2021
  • The designated professional institutions are individually establishing and operating information systems to manage R&D projects and information of researchers; however, systems of each institution do not allow sharing of information, resulting in researchers entering their information and achievements multiple times in each individual system. This paper investigates and analyzes the factors that hinder the research, and designates duplicate entry of researcher information due to the current system designs as the cause. This paper proposes an integration of personnel information as a solution to the issue and suggests a standard for the subject areas and management items for the integration of information. Ultimately, this paper suggests an establishment of a standard database model that is based on the proposed standard, a model that enables the convenient establishment of an information system. According to the results, it is estimated that this process will be effective to over 30% of estimated researchers whose information is entered in duplicate in the individual information system.