• Title/Summary/Keyword: operating characteristic curve

Search Result 585, Processing Time 0.029 seconds

Design of White Balance Correction Processor for High Resolution Full Color LED Display System (고해상도 천연색 LED 디스플레이 시스템을 위한 흰색 보정프로세서의 설계)

  • Lee, Jong-Ha;Ko, Duck-Young
    • 전자공학회논문지 IE
    • /
    • v.46 no.3
    • /
    • pp.12-18
    • /
    • 2009
  • In this paper, we developed white balance correction processor for Full Color LED Display System which could be display uniformity color and soft light by adjusting brightness of red, green, blue pixel, individually. This processor correct brightness by calculating operating current of each pixel(red, green, blue LED) on the basis of characteristic curve of LED device when we named "a" as a specific characteristic value, "b" as a brightness correction value according to using time, "X" as a operating current value, and "Y" as brightness value. As the results, we solved the reduction problem of brightness for long used LED devices, according to increase entire mean of brightness value by adjusting "b" value from the brightness characteristic function.

Intelligent Energy Saving Power System Controller for Telecom DC Power Plant (통신교환기용 DC 전원시스템을 위한 에너지 절약형 지능제어기)

  • Kim, I.J.;Gu, S.W.;Kim, T.Y.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.323-325
    • /
    • 1996
  • The design of Intelligent Energy Saving Power System Controller (IESPSC) for Telecom DC power plants is proposed and presented in this paper. From the past experience. rectifiers for Telecom DC power plants have been operated inefficiently at light loads. IESPSC offers "novel load sharing" approach based on the knowledge of each unit's efficiency of paralleled rectifiers. Neural networks is used for identifying each rectifier's efficiency characteristic curve corresponding to load currents, which is in turn utilized to produce a system efficiency close to the maximum under all operating conditions. In addition, by limiting the number of operating units to the minimum while maintaining high efficiency at the determined loads, a drastic savings in operating cost can be achieved.

  • PDF

Operation and Generation Characteristic of 100MW-Class Wound Rotor Synchronous Generator According to Number of Slots (슬롯 수에 따른 100MW급 권선형 동기발전기 발전특성 및 운전특성 비교)

  • Kim, Chang-Woo;Park, Yo-Han;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.4
    • /
    • pp.523-531
    • /
    • 2019
  • This paper deals with a wound-field synchronous machines(WFSM), with an electromagnet on its salient rotor, as an alternative to a permanent magnet in the rotor. We then examine the power performance characteristics, loss characteristics, V-curves and large short-circuit ratios for a large-scale synchronous generator, considering the leading and lagging operations, based on the finite-element method. We predict the performance of a 100MVA-class generator based on the operating range for a constant short-circuit ratio. At the last, We compared with the electromagnetic characteristics of three model according to number of slots.

Interpretation of Receiver Operating Characteristics (ROC) (ROC(receiver operating characteristics) 해석)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.155-158
    • /
    • 2000
  • The purpose of this paper is to explain the making procedure and the usage of receiver operating characteristic (ROC) curve for interpretation of radiographic images. The conventional radiograms obtained after the creation of the lesions in the acrylic plates and were enhanced in color. The observer were informed of which tooth to examine, the 'a priori' probability of a lesion present and the approximate diameter of the lesions. The two groups of films were interpreted separately by the same observer using the same rating scale. The following rating scale was used: A; definitely no lesion, B; probably no lesion, C; not sure, D; probably a lesion, and E; definitely a lesion. In analysis, for each observer the diagnostic results in terms of true positive (TP) and false positive (FP) decisions were plotted on a graph. The lowest point on the graph represents the TP and FP when only decisions designated as E according to the rating scale are included. The next point shows the TP and FP values when diagnoses designated as D are added and so forth. By connecting such plot points, a receiver operating characteristic (ROC) curves is obtained. The area under the curve represents the diagnostic accuracy resulting from a diagnostic performance at pure chance level and a value of 1.0 at perfect performance. This method has been known as an useful method to detect the minute difference for each radiographic technic, each observer and for the different lesion depths.

  • PDF

Effect the I-T curve and electrical characteristic of fuse elements by plated tin thickness (주석 도금 두께에 따른 퓨즈 가용체의 I-T 커브 및 전기적 특성의 영향)

  • Jin, Sang-Jun;Kim, Eun-Min;Youn, Jae-Seo;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.80-87
    • /
    • 2018
  • In recent years, due to the spread of various renewable energy power sources and the pursuit of high efficiency and low-power consumption, not only trends in the electric power industry but also the consumption, control methods, and characteristics are diversified. However, in this diversified electric power industry, the fuse (which is the core part responsible for safety) has not developed significantly in classical operation mode, and thus, fires continue to occur. In this paper, the effects of low melting-point metal plating and high melting-point metal plating on operating characteristics and IT curve movement of the fuse are investigated in a cartridge fuse, which is a classic fuse manufacturing method. The effects of plating on the thickness of the fuse are investigated, and various operating characteristics of the fuse are implemented. In addition, it is suggested that the plating of the low melting-point metal moves the rated current line of the fuse to a low rating, and moves operating characteristics to characteristics of delay operation. It is possible to design various operating characteristics using this characteristic.

A Study of Test for the Reliability of Weibull Distribution Using Hybrid Censoring (혼합중도중단에 의한 Weibull분포의 신뢰도에 관한 검정의 연구)

  • Yeom, Jun-Geun;Ham, Hyeong-Beom
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.1
    • /
    • pp.48-58
    • /
    • 1992
  • This paper deals with a test procedures on reliablity using hybrid censoring when failure time follows two parameter Weibull distribution. In each case of single and two stage test with hybrid censoring, we construct a operating characteristic curve, and then obtain the censoring number and sample size which the producer's risk and the consumer's risk are both satisfied. This study suggests to determine the expected waiting time at a decision.

  • PDF

Comparisons of the Modified Skip-Lot Sampling Inspection Plans

  • Yang, Chang-Soo;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.4
    • /
    • pp.1183-1189
    • /
    • 2008
  • The general formulas of the operating characteristic(OC) function, average sample number(ASN) and average outgoing quality(AOQ) for the modified n-level skip-lot sampling plan(MMSkSP2) were derived using Markov chain properties by Cho(2008). In this paper, the OC curve, ASN and AOQ of a reference plan, modified two-level, three-level and five-level skip-lot sampling plans are compared.

  • PDF

Prognostic Value of Preoperative Serum CA 242 in Esophageal Squamous Cell Carcinoma Cases

  • Feng, Ji-Feng;Huang, Ying;Chen, Qi-Xun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1803-1806
    • /
    • 2013
  • Purpose: Carbohydrate antigen (CA) 242 is inversely related to prognosis in many cancers. However, few data regarding CA 242 in esophageal cancer (EC) are available. The aim of this study was to determine the prognostic value of CA 242 and propose an optimum cut-off point in predicting survival difference in patients with esophageal squamous cell carcinoma (ESCC). Methods: A retrospective analysis was conducted of 192 cases. A receiver operating characteristic (ROC) curve for survival prediction was plotted to verify the optimum cuf-off point. Univariate and multivariate analyses were performed to evaluate prognostic parameters for survival. Results: The positive rate for CA 242 was 7.3% (14/192). The ROC curve for survival prediction gave an optimum cut-off of 2.15 (U/ml). Patients with CA 242 ${\leq}$ 2.15 U/ml had significantly better 5-year survival than patients with CA 242 >2.15 U/ml (45.4% versus 22.6%; P=0.003). Multivariate analysis showed that differentiation (P=0.033), CA 242 (P=0.017), T grade (P=0.004) and N staging (P<0.001) were independent prognostic factors. Conclusions: Preoperative CA 242 is a predictive factor for long-term survival in ESCC, especially in nodal-negative patients. We conclude that 2.15 U/ml may be the optimum cuf-off point for CA 242 in predicting survival in ESCC.