• Title/Summary/Keyword: operating algorithm

Search Result 1,724, Processing Time 0.025 seconds

Module Type Parallel Driving Algorithm for High Voltage Direct-Current source (고전압 소스를 위한 모듈식 병렬운전 알고리즘)

  • Woo, Byung-Guk;Lee, Yong-Hwa;Kang, Chan-Ho;Cho, Kwan-Yuhl
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.24-27
    • /
    • 2008
  • For high voltage DC-DC converters, the parallel operation of several high voltage source modules is necessary to reduce the material cost. In the conventional parallel operation with HDC module control unit, it is difficult to repair the HDC system for the failure of control unit. To overcome these problems, new parallel operating algorithm for high voltage DC-DC converter is presented. The proposed algorithm has no main control unit and each module can be selected as the master according to the operating conditions. Therefore, one of modules can be replaced as the master immediately when the previous master module is failed. In addition, the extension of extra modules can be simple.

  • PDF

Study on the Effective Operating Method of on-off Valves for a Pneumatic Servo System (개폐식 밸브를 사용한 공기압 서보 시스템의 효율적 밸브 개폐 방법에 관한 연구)

  • 황웅태;최서호;이정오
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.109-116
    • /
    • 1998
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone (MPWMD). The pneumatic system using on-off valves has advantage of simple construction and low cost compared with a system with servo-valves. The performance of the proposed control method is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control compared to the conventional PWMD algorithm. It is also shown that the use of the proposed MPWMD algorithm for the position control significantly reduces the number of valve switching and noise.

  • PDF

A New Algorithm to Reduce the Mal-Operation of DOCR in Bi-directional Power Distribution Systems

  • Jang, Su-Hyeong;Oh, Joon-Seok;Jeong, Ui-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.585-591
    • /
    • 2016
  • DOCR can be used to efficiently increase the reliability and to protect the bi-directional D/L(Distribution Lines). As more DG(Distributed Generation)s attempt to connect the bi-directional D/L, there is an increasing need for studies of how to use DOCR installed in the D/L. This paper investigates the operating principles of DOCR and presents the results an effect of sequence and fault impedance in L-L(Line to Line) fault. An advanced DOCR operating algorithm is proposed to reduce the mal-operation of conventional DOCR. The proposed algorithm is applied to the bi-directional power flow system and shows that it decreases the mal-operation of DOCR through the computer simulation.

A study on modified algorithm to operating train simulation of AT feeding systems (전기철도 AT급전계통의 열차 운형 모의 해석 알고리즘 연구)

  • Choo, Dong-Woog;Kim, Jae-Chul;Jung, Yong-Chul;Jun, Yong-Ju;Lim, Seong-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.449-451
    • /
    • 2001
  • This study presents a study on modified algorithm to operating train simulation of AT feeding systems. In this study equivalent impedance is constructed by $Z_c,\;Z_r,\;Z_f,\;Z_{cr},\;Z_{rf},\;Z_{fc}$. The train current flows through the all auto-transformer corresponding to track impedance. To calculate train voltage from analyzing the railway systems, the algorithm is based on the K. C. L, K. V. L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that the proposed method is easily applied.

  • PDF

A Study on the File Allocation in Distributed Computer Systems (분산 컴퓨터 시스템에서 파일 할당에 관한 연구)

  • 홍진표;임재택
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.4
    • /
    • pp.571-579
    • /
    • 1990
  • A dynamic relocation algorithm for non-deterministic process graph in distributed computer systems is proposed. A method is represented for determining the optimal policy for processing a process tree. A general database query request is modelled by a process tree which represent a set of subprocesses together with their precedence relationship. The process allocation model is based on operating cost which is a function fo selection of site for processing operation, data reduction function and file size. By using expected values of parameters for non-deterministic process tree, the process graph and optimal policy that yield minimum operating cost are determined. As process is relocated according to threshold value and new information of parameters after the execution of low level process for non-deterministic process graph, the assigned state that approximate to optiaml solution is obtained. The proposed algorihtm is heuristic By performing algorithm for sample problems, it is shown that the proposed algorithm is good in obtaining optimal solution.

  • PDF

Maximum power point tracking method for building integrated PV system (건물용 태양광 컨버터의 최대전력 추종 기법 개발)

  • Yu, Byung-Gyu;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.299-303
    • /
    • 2011
  • This paper proposes a novel sensorless maximum power point tracking (11PPT) algorithm for PV systems. The method is based on dividing the operating time into several intervals in which the PV terminals are short circuited in one interval and the calculated short-current of the PV is obtained and used to determine the optimum operating point where the maximum output power can be obtained. The proposed MPPT algorithm has been introduced into a current-controlled boost converter whose duty ratio is controlled to the maintain MPP condition. The same sequence is then repeated regularly capturing the PV maximum power. The main advantage of this method is eliminating the current sensor. Meanwhile, this MPPT algorithm reduces the power oscillations around the peak power point which occurs with perturbation and observation algorithms. In addition, the total cost will decrease by removing the current sensor from the PV side. Finally, simulation results confirm the accuracy of the proposed method.

  • PDF

Panoramic-Stereopic Monitoring System for Tele-Operating Excavator by Using Center-viewpoint Corresponding Algorithm (중심시점 일치 알고리즘 기반 원격제어 굴삭기의 파노라믹 입체 모니터링 시스템)

  • Kim, Bong-Seok;Park, Chang-Woo;Jun, Se-Woong;Lee, Jong-Bae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.74-77
    • /
    • 2007
  • In this paper, we propose a system which can display panoramic-stereopic image for tele-operating excavator. the system was implemented by using center-viewpoint corresponding algorithm and image mosaic process. We could obtain remarkable result from the survey among the ex-pert of excavator. We also design a control station with RF transfer module, H.264 codec module and suggested algorithm. Especially, our system shows a superb performance on cubic effect and presence sense of a field of excavating work.

  • PDF

A Study on the Development of the Minimization Algorithm of Total Operating Cost in a Multi-stage Distribution System by the Partial Delivery Method (분납조달 방법을 통한 다단계 분배시스템의 총운전비용 최소화 알고리즘 개발에 관한 연구)

  • 최진영
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.139-144
    • /
    • 1997
  • The objective of this study is to establish an actual optimization strategy for the traditional multi-stage distribution system which consists of factory warehouse, central distribution warehouse, and regional distribution warehouse under the basic assumption of distribution system. A minimization algorithm of total operating cost in a multi-stage distribution system was developed by expanding the previously existing algorithm through consideration of additional transportation environment. Alternative non-linear transportation costs for the same travel distance can be applied for the multi-stage distribution system by estimating the corresponding characteristic values through the collection of the actual data representing the change of transportation circumstances.

  • PDF

Fault Detection of BLDC Motor Based on Operating Characteristic (BLDC 전동기 운전 특성을 이용한 새로운 고장 검출 기법 구현)

  • Lee, Jung-Dae;Park, Byoung-Gun;Kim, Tae-Sung;Ryu, Ji-Su;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.325-327
    • /
    • 2007
  • This paper proposes a novel sensorless fault detection algorithm for a brushless DC(BLDC) motor drive system. This proposed method is configured without the additional sensor for fault detection and identification. The fault detection and identification are achieved by a simple algorithm using the operating characteristic of the BLDC motor. This proposed method can also be embedded into existing BLDC motor drive systems as a subroutine without excessive computational effort. The feasibility of a novel sensorless fault detection algorithm is validated in simulation.

  • PDF

C-link Ripple Voltage Compensation Algorithm for Integrated ESS and UPS System with PV Generation (태양광 발전을 갖는 통합 ESS 및 UPS 시스템의 직류 링크 맥동전압 보상 알고리즘)

  • Kim, Min-Gi;Choi, Bong-Yeon;Kang, Jin-Wook;Kim, Jun-Gu;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.443-444
    • /
    • 2014
  • Using the ESS(Energy Storage System) as a UPS(Uninterruptible Power Supply) is being studied recently. When the system is operating at UPS mode in integrated ESS and UPS system, the grid supplying power is disconnected and power from PV generation and battery are supplying to load. Operating in UPS mode, when PV generation power is diminished by partial or total clouded situation, DC-link voltage fluctuates. The fluctuation of DC-link voltage influences the load and system as sensitive loads may malfunction. This paper suggests the DC-link ripple voltage compensation algorithm in bi-directional converter. The algorithm stabilize the DC-link and load voltage.

  • PDF