• Title/Summary/Keyword: opening a door

Search Result 187, Processing Time 0.028 seconds

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

A Research on Predicting Dynamic Behavior of Door Locking System for Side Impact Safety

  • Kwak, K.T.;Choi, D.W.;Seo, S.W.
    • Journal of Auto-vehicle Safety Association
    • /
    • v.5 no.1
    • /
    • pp.25-30
    • /
    • 2013
  • The main purpose of this research is to predict dynamic behavior of door locking system for side impact safety and the design process to avoid door opening is introduced. The equations of motion that represent the system are obtained from the energy equation. From them, the motion of door handle is predicted by using Runge-Kutta $4^{th}$ order method and the simulation result is compared with the real crash data. Also, the design guide to define the properties of door locking system from the standpoint of avoiding door opening phenomenon is introduced.

A study on the Beehive Door Opening and Closing System using a Hornet Sound Analysis

  • Kim, Joon Ho;Han, Wook;Chung, Wonki
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.393-396
    • /
    • 2022
  • Recently, rapid climate change has had a significant impact on the ecosystem of honeybees. In addition, the problem of Vespa Hornets invasion of colonies has a fatal impact on the bee ecosystem, independent of climate change. Especially in late summer. This study relates to a method for preventing Vespa Hornets attack. In this study, we developed a Vespa Hornets sound detection device was developed by collecting and analyzing the sound of a Vespa Hornets and applying IoT technology. The developed device detects the sound of a Vespa Hornets when Vespa Hornets appears around the hive of the bees and sends a signal to automatically close the door of the beehive. The device that receives the signal drives the motor that controls the honeycomb door to close the beehive door. The Vespa Hornets sound detection device operates until no Vespa Hornets sound is detected. The system developed by us is expected to be installed in the beehives of actual beekeeping farms to dramatically reduce the damage caused by by Vespa Hornets.

Position Control Algorithm of a PMSM for the Elevator Door System (엘리베이터 도어 시스템을 위한 PMSM의 위치제어 알고리즘)

  • Song, Ki-Young;Cho, Kwan-Yuhl;Kim, Hag-Wone;Oh, Hyun-Cheal
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.17-18
    • /
    • 2012
  • Generally, speed control system is used to control the elevator door. The whole speed profile must be installed in the speed controller of the door control system. However, it is not easy to modify the speed profile when door opening size and time are changed. In this paper, the making speed profile is discussed by the door opening size and time. The position control algorithms of PMSM for elevator door system are compared with general speed control, position control method with speed controller, and position control with speed command feedforward compensation by simulation using MATLAB/SIMULINK.

  • PDF

Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door (굴뚝효과와 외부출입문 개방을 고려한 부속실 제연)

  • Yongkwang Kim;Zudal Son;Seoyoung Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

The Interface Scheme and Application Between Rolling Stock System and PSD (철도차량시스템과 PSD간 인터페이스 방안 및 적용 현황)

  • Lee Jong-Seong;Min Young-Ki;Kim Kyoung-Shik;Choi Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1510-1512
    • /
    • 2004
  • Platform Screen Door System is a facility on platform to separate platform from track, having automatic sliding door structures interlocked to opening and closing of train door with integrated control unit. When a train comes to a stop at a designed position at a station, onboard ATC/ATO system transmits train berth signal to wayside signaling system. In case of automatic/driverless operation, opening and closing of the Platform Screen Door will be controlled by wayside signaling system. Unfortunately, we often see the case in news that passengers fall into track and their contact with train lead to critical accidents. However, passengers will be free from such accidents on the platform with the Platform Screen Door System. Especially during the rush hours, to ensure passenger's safety and smooth getting on & off, it is necessary to arrange. some station staffs on the platform without the Platform Screen Door System. On the other hand, the Platform Screen Door System will realize such operation by fewer staffs. Due to the above reasons, the Platform Screen Door System is becoming more popular in subway system recently.

  • PDF

A Numerical Analysis for Stress Concentration of Openings in Offshore Tubular Steel Tower under Design Loading Condition (설계하중조건에 따른 해상풍력 강재타워 출입구에 발생되는 응력집중에 대한 해석적 연구)

  • Reyno, Hannah;Park, Jong-Sup;Kang, Sung-Yong;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1516-1523
    • /
    • 2015
  • This study investigates the stress concentration factor of a door opening of an offshore tubular steel tower. The tubular steel tower is subjected to eight (8) different load combinations which are deemed to be normal and abnormal operating cases for the ultimate limit state and serviceability limit state. Analytical method using parametric equations and numerical method of finite element are used to analyze the stress components as well as any translations or rotations where the flow of stress is interfered with. A finite element program, ABAQUS, is used for the numerical method analysis. Trends of the stress concentration in the localized area near the opening are studied, and points of interest are defined for comparison among three different cases of tubular steel tower: without door and without reinforcement; without door opening and with reinforcement; and with door opening and with reinforcement. Findings are tabulated and shown in illustrative charts, and conclusions are made.

Development of Automatic Operating System for Exit Door using RF (무선을 이용한 비상문 자동개폐 시스템 개발)

  • Lim Youn-Sub;Hwang Byung-Kon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, we develop a control system with fire receiver and emergency light that controls (manages) emergency door by wireless signals which prevents crime but also helps evacuate in (fire) emergency. This automatic door operator can be installed on any buildings which have a problem of opening or shutting emergency doors, and it is especially good for buildings with high fire vulnerabilities such as complex buildings, apartments and multistoried buildings without easy control of rooftop doors.

  • PDF

Geometric Effects of Compartment Opening on Fuel-Air Mixing and Backdraft Behavior (개구부의 기하학적 형상이 구획실의 연료-공기 혼합특성 및 백드래프트 거동에 미치는 영향)

  • Ha, Suim;Oh, Chang Bo
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.30-38
    • /
    • 2019
  • Mixing characteristics and backdraft dynamics were investigated using large eddy simulation for compartments initially filled with methane fuel. Four different opening geometries, i.e. conventional door opening case (Door) and the cases where horizontal door was implemented on the upper ($Slot_U$), middle ($Slot_M$) and lower part ($Slot_L$) of side wall, were considered in the simulations. For cases without ignition, the amounts of inflow oxygen and outflow fuel from the compartment opening were, from largest to smallest, Door > $Slot_U$ ~ $Slot_M$ > $Slot_L$. However, the fuel and oxygen were the best mixed for the $Slot_U$ case while the fuel and oxygen were not well mixed and in relatively separated two layers for the $Slot_L$ case. The global equivalence ratio defined by the amounts of fuel and oxygen in the compartment was not correlated reasonably with the peak pressure of backdraft. The peak pressure during backdraft was the highest for the $Slot_U$ case, a well mixed condition of fuel and air, and backdraft was not found for the $Slot_L$ where the pressure rise was not so high due to the mixing status. The peak pressures for the Door and $Slot_M$ cases were in between Door and $Slot_L$ cases. The peak pressure during backdraft was well correlated with the total amount of heat release until the instance of backdraft occurrence.

Numerical analysis on the rapid fire suppression using a water mist nozzle in a fire compartment with a door opening

  • Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.410-423
    • /
    • 2019
  • Fire suppression using a water mist nozzle directly above an n-Heptane pool in a fire compartment with a door opening was numerically investigated using the Fire Dynamics Simulator (FDS) for the purpose of application in nuclear power plants. Input parameters for the numerical simulation were determined by experimental measurements. Water mist was activated 10 s after the fire began. The sensitivity analysis was conducted for three input parameters: total number of cubic cells of 6032-2,926,400, droplets per second of 1000-500,000, and extinguishing coefficient of 0-100. In a new simple calibration method of this study, the extinguishing coefficient yielding the fire suppression time closest to that measured by experiments was found for use as the FDS simulation input value. When the water mist jet flow made contact with the developed fire, the heat release rate instantaneously increased, and then rapidly decreased. This phenomenon occurred with a displacement of the flame near the liquid fuel pool. Changing the configuration of the door opening with different aspect ratios and opening ratios had impact on the maximum value of the heat release rate due to the flame displacement.