• Title/Summary/Keyword: open-path

Search Result 386, Processing Time 0.02 seconds

Void Closing Conditions of Large Ingot by Path Schedules (대형 잉곳의 기공압착 효과 향상을 위한 폐쇄조건 연구)

  • Choi, I.J.;Choi, H.J.;Kim, D.W.;Choi, S.;Lim, S.J.
    • Transactions of Materials Processing
    • /
    • v.19 no.8
    • /
    • pp.480-485
    • /
    • 2010
  • In this work, the closing behavior of cylindrical-shaped voids was experimentally investigated according to various parameters such as reduction ratio in height, initial void size and billet rotation during hot open die forging process. The reduction ratio in height, number of path, and billet rotation were chosen as key process parameters which influence the void closing behavior including the change of void shape and size. On the other hand, values of die overlapping and die width ratio were set to be constant. Void closing behavior was estimated by microscopic observation. Based on the observations, it was confirmed that application of billet rotation is more efficient to eliminate the void with less reduction ratio in height. The experimental results obtained from this study could be helpful to establish the optimum path schedule of open die forging process.

A Hybrid Genetic Algorithm for Optimizing Torch Paths to Cut Stock Plates Nested with Open Contours (열린 윤곽선 부재로 이루어진 판재의 절단가공경로 최적화를 위한 혼합형 유전알고리즘)

  • Lee, Moon-Kyu
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.3
    • /
    • pp.30-39
    • /
    • 2010
  • This paper considers a problem of optimizing torch paths to cut stock plates nested with open contours. For each contour, one of the two ending points is to be selected as a starting point of cutting with the other being the exit point. A torch path is composed of a single depot and a series of starting and ending points of contours to be cut. The torch path optimization problem is shown to be formulated as an extended version of the standard travelling salesman problem. To solve the problem, a hybrid genetic algorithm with the local search of torch paths is proposed. The genetic algorithm is tested for hypothetical problems whose optimal solutions are known in advance due to the special structure of them. The computational results show that the algorithm generates very near optimal solutions for most cases of the test problems, which verifies the validity of the algorithms.

A Study on the Performance Analysis of an Extended Scan Path Architecture (확장된 스캔 경로 구조의 성능 평가에 관한 연구)

  • 손우정
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.105-112
    • /
    • 1998
  • In this paper, we propose a ESP(Extended Scan Path) architecture for multi-board testing. The conventional architectures for board testing are single scan path and multi-scan path. In the single scan path architecture, the scan path for test data is just one chain. If the scan path is faulty due to short or open, the test data is not valid. In the multi-scan path architecture, there are additional signals in multi-board testing. So conventional architectures are not adopted to multi-board testing. In the case of the ESP architecture, even though scan path is either short or open, it doesn't affect remaining other scan paths. As a result of executing parallel BIST and IEEE 1149.1 boundary scan test by using the proposed ESP architecture, we observed that the test time is short compared with the single scan path architecture. By comparing the ESP architecture with single scan path responding to independency of scan path, test time and with multi-scan path responding to signal, synchronization, we showed that the architecture has improved results.

  • PDF

On the Effect of Tube Attenuation on Measuring Water Vapor Flux Using a Closed-path Hygrometer (폐회로 습도계를 이용한 수증기 플럭스 관측시관의 감쇠 효과에 관하여)

  • Hong Jinkyu;Kim Joon;Choi Taejin;Yun Jin-il;Tanner Bert
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.3
    • /
    • pp.80-86
    • /
    • 2000
  • Eddy covariance method is widely used in measuring vertical fluxes of mass and energy between the atmosphere and the biosphere. In this method, scalar concentration is measured with either open-path or closed-path sensors. For the latter, fluctuations of scalar concentration are attenuated as the sample travels through a long tube, resulting in flux loss. To quantify this tube attenuation, water vapor concentrations measured with both closed-path and open-path sensors were analyzed. Our statistical analysis showed that the power spectral density obtained from the closed-path sensor was different from that from the open-path sensor in the frequency range of > 0.5 Hz. The loss of water vapor flux due to tube attenuation was < 5% during midday. At nighttime, however, the flux loss increased significantly because of the low wind speeds and the weak turbulence sources. Theoretical calculation for the tube attenuation showed a small bias in high frequency range probably because of the interaction of sticky water vapor with a tube wall.

  • PDF

OpenFlow Network Performance Evaluation under Heterogeneous Traffic (혼합트래픽 환경에서 Open Flow 네트워크 성능 평가)

  • Yeom, Jae Keun;Lee, Chang-Moo;Choi, Deok Jae;Seok, Seung Jun;Song, Wang Cheol;Huh, Jee-Wan
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.46-53
    • /
    • 2012
  • The traffic in research network for the new structure of the network and new service research has the various properties. From the perspective of a specific traffic point of view, transmission of traffic with different requirements using a single routing protocol is an obstacle to satisfy requirements. In this study, we classify the properties of the traffic into two types. We propose the way that we can get the overall optimization effect, the experiment proves it by providing independent multiple forwarding path by applying optimized algorithm by types. In order to distinguish each type of traffic we use the ports on the switch and in order to implement independent path we apply OpenFlow system. In other words, we present the measure that can be implemented to improve the satisfaction of the traffic by making multiple paths by OpenFlow controller according to the type of traffic and by enforcing in Forwarder.

OFPT: OpenFlow based Parallel Transport in Datacenters

  • Liu, Bo;XU, Bo;Hu, Chao;Hu, Hui;Chen, Ming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.10
    • /
    • pp.4787-4807
    • /
    • 2016
  • Although the dense interconnection datacenter networks (DCNs) (e.g. FatTree) provide multiple paths and high bisection bandwidth for each server pair, the single-path TCP (SPT) and ECMP which are widely used currently neither achieve high bandwidth utilization nor have good load balancing. Due to only one available transmission path, SPT cannot make full use of all available bandwidth, while ECMP's random hashing results in many collisions. In this paper, we present OFPT, an OpenFlow based Parallel Transport framework, which integrates precise routing and scheduling for better load balancing and higher network throughput. By adopting OpenFlow based centralized control mechanism, OFPT computes the optimal path and bandwidth provision for each flow according to the global network view. To guarantee high throughput, OFPT dynamically schedules flows with Seamless Flow Migration Mechanism (SFMM), which can avoid packet loss in flow rerouting. Finally, we test OFPT on Mininet and implement it in a real testbed. The experimental results show that the average network throughput in OFPT is up to 97.5% of bisection bandwidth, which is higher than ECMP by 36%. Besides, OFPT decreases the average flow completion time (AFCT) and achieves better scalability.

The study for VOCs analysis in long path by open path FT-IR spectrometer (Open path FT-IR spectrometer를 사용한 원거리의 VOCs 측정에 관한 연구)

  • Cho, Nam Wook;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.108-113
    • /
    • 2014
  • The harmful materials as volatile organic compounds (VOCS) that is easy for gas to be changed from liquid on ambient temperature, those should be controlled by Korea Chemicals Management Association. The VOCs samples should be collected directly in place so that those could be analyzed. Generally but it couldn't avoid to have the risk of analyst. Moreover, if there is the place limited to entrance, it is impossible to collect directly and measure. Owing to such problem, it tried to be solved by open path FT-IR spectrometer that could be studied on the combustion gases within long path and VOCs samples were tried to measure to large volume by remote and real time. Firstly, it was to investigate optimized measured length between the system and benzene sample of VOCs. As result, The optimized measured length was confirmed with 15 meter length and the qualitative analysis could be measured on seven VOC samples. The calibration curve as quantitative analysis of benzene samples could be worked. On the basis of the result, the system as remote monitor could show to have potentiality.

A STUDY ON THE DESIGN OF SIMPLE RECORDING DEVICE TO TRACE THE MANDIBULAR MOVEMENTS (하악골운동 추적을 위한 단순기록장치 고안에 관한 연구)

  • Kim, Sang-Soo;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.253-267
    • /
    • 1987
  • The purpose of this study was to improve limitations and disadvantages of the mechanical pantograph and the Visi-Trainer, and to design the reliable and reproducible device mandibular movement tracking device (MMTD) that is more simple, convenient and save the chair time than the mechanical pantograph and Visi-Trainer. MMTD was consist of head frame, horizontal bar, condylar path tracking stylus holders, anterior path tracking stylus holder, two condylar path plastic recording plates, one anterior path plastic recording plate, toggles and open occlusal clutch. To prove the reliability and reproducibility of MMTD, a five adults were selected and mandibular condylar movement was recorded one time by the mechanical pantographic tracing and MMTD. The border movement recording of the mandibular incisor (frontal, sagittal and horizontal) was also recorded by Visi-Trainer and the MMTD. The obtained results were as follows; 1. The condylar movement path (sagittal, horizontal) of the MMTD was not coincidence with that of mechanical pantograph. 2. Measurements of the angulation which established between working and balancing path records by use of the mechanical pantograph and MMTD, there was no significance. 3. In a view of MMTD's reproducibility, there was revealed almost similar recording pattern. 4. The border movement recording of the mandibular incisor by the MMTD and the Visi-Trainer showed almost same reliability and reproducibility. 5. The subjects were able to his original mandibular movements by use of open occlusal clutch in the MMTD.

  • PDF

Modelling and performance analysis for the end-to-end path tracing managment in ATM network (ATM망의 단대단 통신로 추적관리의 모델링 및 성능분석)

  • 박명환;안중영;조규섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.9
    • /
    • pp.2385-2401
    • /
    • 1996
  • In this paper, a management model and a path trace algorithm are proposed for the end-to-end path tracing management in ATM network. Proposedmodel is based on the TINA(Telecommunication Information Networking Architecture) and computational object(CO) of ODP(Open Distributed Processing).We related computational object for the path trace to another computational object which covers the ATM routing and established operational procedure according to this relationship. This procedure identifies the end-to-end by way of tracing the ATM connections then collect identification information on the that path. End-to-end trace is performed on the network management level. Broadcasting-with-synchronized-control and GTM(Global Ticket Method) are proposed as path trace algorithm considering the real time properties and data ingetrity. Computer simulations are also performed to evaluate the performance of the proposed algorithm and its resuls are shown in this paper.

  • PDF