• Title/Summary/Keyword: open-circuit fault

Search Result 74, Processing Time 0.028 seconds

A Study on the Neutral Point Potential Variation under Open-Circuit Fault of Three-Level NPC Inverter (3레벨 NPC 인버터 개방성 고장 시 중성점 전압변동에 관한 연구)

  • Park, Jong-Je;Park, Byoung-Gun;Ha, Dong-Hyun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.333-342
    • /
    • 2009
  • Three-level Diode Clamped Multilevel Inverter, generally known as Neutral-Point-Clamped (NPC) Inverter, has an inherent problem causing Neutral Point (NP) potential variation. Until now, in many literatures NP potential problem has been investigated and lots of solutions have also been proposed. However, under fault and fault tolerant control, distinctive feature for NP potential variation problem was rarely published from the standpoint of reliability. In this paper, NP potential is analytically investigated both normal and faulty conditions under carrier based PWM. Subsequently, relation between fault detection time and size of capacitor is analyzed. This information is explored by simulation and experiment results, which contribute to enhance the reliability of inverter system.

Variation of Transient-response in Open-ended Microstrip Lines with Optically-controlled Microwave Pulses

  • Wang, Xue;Kim, Kwan-Woong;Kim, Yong-K.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.53-57
    • /
    • 2009
  • In this paper we develop a method to observe faults in semiconductor devices and transmission lines by calculating the variation of the reflection function in a dielectric microstrip line that has an open-ended termination containing an optically induced plasma region. It is analyzed with the assumption that the plasma is distributed homogeneously in laser illumination. With the non linear material of degradation, the concentration of the carrier in the part of the material has changed. Since the input wave has produced the phenomenon of reflection, the input signal to the open-ended microstrip lines can be observed on reflection to identify the location of the fault. The characteristic impedances resulting from the presence of plasma are evaluated by the transmission line model. The variation of the reflection wave in the microwave system has been calculated by using an equivalent circuit model. The transient response has been also evaluated theoretically for changing the phase of the variation in the reflection. The variation of characteristic response in differentially localized has been also evaluated analytically.

Characterization Method for Testing Circuit Patterns on MCM/PCB Modules with Electron Beams of a Scanning Electron Microscope (MCM/PCB 회로패턴 검사에서 SEM의 전자빔을 이용한 측정방법)

  • Kim, Joon-Il;Shin, Joon-Kyun;Jee, Yong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.9
    • /
    • pp.26-34
    • /
    • 1998
  • This paper presents a characterization method for faults of circuit patterns on MCM(Multichip Module) or PCB(Printed Circuit Board) substrates with electron beams of a SEM(Scanning Electron Microscope) by inducing voltage contrast on the signal line. The experimentation employes dual potential electron beams for the fault characterization of circuit patterns with a commercial SEM without modifying its structure. The testing procedure utilizes only one electron gun for the generation of dual potential electron beams by two different accelerating voltages, one for charging electron beam which introduces the yield of secondary electron $\delta$ < 1 and the other for reading beam which introduces $\delta$ > 1. Reading beam can read open's/short's of a specific net among many test nets, simultaneously discharging during the reading process for the next step, by removing its voltage contrast. The experimental results of testing the copper signal lines on glass-epoxy substrates showed that the state of open's/short's had generated the brightness contrast due to the voltage contrast on the surface of copper conductor line, when the net had charged with charging electron beams of 7KV accelerating voltages and then read with scanning reading electron beams of 2KV accelerating voltages in 10 seconds. The experimental results with Au pads of a IC die and Au plated Cu pads of BGA substrates provided the simple test method of circuit lines with 7KV charging electron beam and 2KV reading beam. Thus the characterization method showed that we can test open and short circuits of the net nondestructively by using dual potential electron beams with one SEM gun.

  • PDF

Implementation of a Network Provisioning System with User-driven and Trusty Protection Management

  • Lim, H.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.11
    • /
    • pp.4720-4738
    • /
    • 2015
  • Proper management on user-driven virtual circuits (VCs) is essential for seamless operation of virtual networks. The Network Provisioning System (NPS) is useful software for creating user-driven VCs automatically and must take fault management into account for physical layer impairments on user-driven VCs. This paper addresses a user-driven and trusty protection management in an NPS with an open standard Network Service Interface (NSI), as a contribution to show how to implement the user-driven and trusty protection management required for user-driven VCs. In particular, it provides a RESTful web service Interface for Configuration and Event management (RICE) that enable management of a distinguished data and control plane VC status between Network Service Agents (NSAs) in the event of a node or link fault and repair in a domain. This capability represents a contribution to show how network and protection events in a domain can be monitored between NSAs (NPSs with the NSI) in multiple domains. The implemented NPS controls and manages both the primary and backup VC with disjoint path in a user-driven manner. A demonstration to verify RICE API's capability is addressed for the trusty protection in the dynamic VC network.

Managed Object and Distributed Network Management Model in Open Interface of OBS Network (개방형 인터페이스가 적용된 OBS 망의 관리객체 및 분산 망 관리 모델)

  • Kwon TaeHyun;Kim ChoonHee;Cha YoungWook
    • The KIPS Transactions:PartC
    • /
    • v.12C no.3 s.99
    • /
    • pp.449-456
    • /
    • 2005
  • Optical burst switching (OBS) overcomes the inefficient resource usage of optical circuit switching and minimizes the optical buffering requirement of optical packet switching. General switch management protocol (GSMP) is an open interface between a label switch and a controller, and it provides connection, configuration, performance, event management and synchronization. GSMP open interface in the OBS network allows the implementation of OBS switch to be simple by separating the data forward plane from the control plane. We defined managed objects to support connection, configuration, performance, and fault management for the management of OBS network in the GSMP open interface. We proposed the network management model, in which the above managed objects are distributed in a controller and an OBS switch according to network management functions. We verified the possibility of connection management using distributed network management model in the GSMP open interface of OBS network by implementing GSMP and network management functions with managed objects of OBS.

Detection Method of an Open Circuit Fault in a Grid Connected NPC Inverter System (계통연계 형 NPC인버터 시스템의 개방성 고장진단)

  • Jang, Dae-Min;Choi, Ui-Min;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.417-418
    • /
    • 2011
  • 본 논문은 계통연계 형 3-레벨 NPC(Neutral Point Clamped)인버터의 고장진단 방법을 제안한다. 제안하는 고장진단 방법은 스위칭 소자의 개방고장 진단뿐만 아니라 고장 난 스위칭 소자의 위치 또한 판별 할 수 있다. 스위칭 소자의 고장 진단은 콘코디아 변환(Concordia transformation)에 의한 전류패턴의 반지름 변화로 판단 할 수 있다. 고장 난 스위칭 소자의 위치는 기존의 콘코디아 변환(Concordia transformation)에 의한 전류패턴을 분석하는 방법에 간단한 스위칭 동작을 추가함으로써 구분 할 수 있다. 제안하는 기법은 추가적인 센서가 필요하지 않고 전류신호에 기반을 두고 있으므로 시스템의 복잡한 모델링이 필요하지 않은 장점이 있다. 본 논문은 10kW급 태양광 계통연계 시스템을 모의한 시뮬레이션을 바탕으로 제안한 기법의 타당성을 검증한다.

  • PDF

A Study on Heat-Flux Evaluation for Cable Fire Including Diagnostic Methodology for Degradation in Nuclear Power Plants (원전 케이블 화재 열속평가 및 열화 진단방법에 관한 연구)

  • Lim, Hyuk-Soon;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.20-25
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments. The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a multi-core cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the characteristic of cable fire is investigated and the heat-flux evaluation for cable fire is studied. Moreover, a diagnostic methodology for degraded cable in nuclear power plants is presented.

An Integrated Setting-Coordination Program for Protective Relay of Transmission Systems (송전계통 보호계전기 정정협조 종합프로그램)

  • Kim, Young-Il;Lee, Seung-Jae;Choi, Myeon-Song;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.229-231
    • /
    • 1998
  • One of the most important requirements for the development of computerized relay setting system is its openness to accommodate the various changes like new panel additions. This paper describes the relay setting system(PROSET2000), which has an open system architecture and adopts the object oriented programming paradigm. Its main features include the intelligent fault type identification, automatic running of the short circuit analysis, run-time rulebase modification, automatic documentation, etc.

  • PDF

Design of Compensation Circuits for LED Fault in Constant Current Driving (정전류 구동에서 LED 고장 보상 회로 설계)

  • Lee, Kwang;Jang, Min-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.71-76
    • /
    • 2022
  • Since brightness is proportional to the operating current, a method of connecting several LEDs in series and driving with a constant current source is widely used for driving circuits of LED lights. Because several LEDs are connected in series, if some LEDs open due to a fault, the current path is broken and all other LEDs connected in series are turned off. In this paper, we designed a circuit to solve this problem by connecting a Zener diode having a breakdown voltage of about 0.4V higher than the LED operating voltage in parallel with each LED to create a current bypass in case of LED failure. Through simulations and experiments, it was confirmed that the current of the Zener diode hardly flows when the LED is operating normally, and that the Zener diode stably operates as a current bypass when the LED fails.

Inverter type High Efficency Neon Transformers for Neon Tubes (인버터식 고효율 네온관용 변압기)

  • 변재영;김윤호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.22-29
    • /
    • 2002
  • The conventional neon transformer systems are very bulky and heavy because it consist of leakage type transformers made of silicon steel plates. In addition, it has problems in noise by a neon transformer and in possibilities of fire and electrical shock when neon tubes are destroyed. A protection circuit is designed for all types of neon transformer loaded with one or more neon tubes. Whenever the neon tube fails to be started up, comes to the life end, encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. To improve such problems, in this paper, a new type of neon power supply systems for neon tube is designed and implemented using inverter type circuits and a newly designed lightweight transformer. In the developed neon transformer system, a 60[Hz]power input is converted to 20[KHz]high frequency using half-wave inverters, thereby the transformer reduces its size by 1/5 in volume and 1/10 in weight.