• Title/Summary/Keyword: open radiation field

Search Result 86, Processing Time 0.02 seconds

Aperture-Miniaturized Antenna Loaded with Split Ring Resonator Array

  • Oh, Soon-Soo;Park, Wook-Ki;Kang, Suk-Youb;Park, Hyo-Dal
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.315-317
    • /
    • 2009
  • In this letter, a novel antenna with a miniaturized aperture is proposed. The substrate including a split-ring resonator array is inserted into a size-reduced open-ended waveguide. For a low return loss and high radiation efficiency, the ring arrangement is optimized, and a stepped transition using H-plane discontinuity is proposed. The proposed antenna achieves a 70% aperture reduction compared to a conventional standard waveguide antenna of WR-187 (47.6 mm${\times}$22.2 mm). The return loss drops significantly at three frequencies, and a reasonable gain is achieved. The aperture-miniaturized antenna can be used in many antenna applications such as near-field measurement.

  • PDF

The analysis of aoustic scattering problems by Indirect PFBEM with cylinder model (파워흐름경계요소법을 이용한 원통형 구조물에 대한 음파산란해석)

  • Jeong, Pill-Woo;Hong, Suk-Yoon;Lee, Ho-Won;Kwon, Hyun-Wung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.90-93
    • /
    • 2005
  • Power Flow Boundary Element Method(PFBEM) has been used as a promising tool for radiation problems in the midium-to-high frequency. PFBEM is the numerical method that applies boundary element technique to Power Flow Analysis (PFA). Indirect PFBEM is developed for acoustic scattering problems in the open field and in various frequency. To verify the analytic results of indirect PFBEM for acoustic scattering problems are compared with those of SYSNOISE, and the results using two analytic methods show a good agreement.

  • PDF

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

AKARI FAR-INFRARED ALL-SKY SURVEY MAPS

  • Doi, Yasuo;Komugi, Shinya;Kawada, Mitsunobu;Takita, Satoshi;Arimatsu, Ko;Ikeda, Norio;Kato, Daisuke;Kitamura, Yoshimi;Nakagawa, Takao;Ootsubo, Takafumi;Morishima, Takahiro;Hattori, Makoto;Tanaka, Masahiro;White, Glenn J.;Etxaluze, Mireya;Shibai, Hiroshi
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.111-116
    • /
    • 2012
  • Far-infrared observations provide crucial data for the investigation and characterisation of the properties of dusty material in the Interstellar Medium (ISM), since most of its energy is emitted between ~ 100 and $200{\mu}m$. We present the first all-sky image from a sensitive all-sky survey using the Japanese AKARI satellite, in the wavelength range $50-180{\mu}m$. Covering > 99% of the sky in four photometric bands with four filters centred at $65{\mu}m$, $90{\mu}m$, $140{\mu}m$, and $160{\mu}m$ wavelengths, this achieved spatial resolutions from 1 to 2 arcmin and a detection limit of < 10 MJy $sr^{-1}$, with absolute and relative photometric accuracies of < 20%. All-sky images of the Galactic dust continuum emission enable astronomers to map the large-scale distribution of the diffuse ISM cirrus, to study its thermal dust temperature, emissivity and column density, and to measure the interaction of the Galactic radiation field and embedded objects with the surrounding ISM. In addition to the point source population of stars, protostars, star-forming regions, and galaxies, the high Galactic latitude sky is shown to be covered with a diffuse filamentary-web of dusty emission that traces the potential sites of high latitude star formation. We show that the temperature of dust particles in thermal equilibrium with the ambient interstellar radiation field can be estimated by using $90{\mu}m$, $140{\mu}m$, and $160{\mu}m$ data. The FIR AKARI full-sky maps provide a rich new data set within which astronomers can investigate the distribution of interstellar matter throughout our Galaxy, and beyond.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters (선량계측인자에 따른 기능강화동적쐐기와 금속쐐기의 비교)

  • Lee Jeong-Woo;Hong Semie;Choi Kyoung-Sik;Chung Jin-Beom;Choe Bo-Young;Jang Hong Seok;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.70-76
    • /
    • 2005
  • For clinical implementation of Enhanced Dynamic Wedge (EDW), it is necessary to adequately analyze and commission its dosimetric properties in comparison to common physical metal wedge (MTW). This study was implemented with the essential measurements of parameters for clinical application, such as percentage depth dose, peripheral dose, surface dose, effective wedge factor, and wedge profile. In addition, through the comparison study of EDW with open and MTW, the analysis was performed to characterize the EDW. We also compared EDW dose profiles of measured values using chamber array 24 (CA24) with calculated values using radiation treatment planning system. PDDs of EDW showed good agreements between $0.2\~0.5\%$ of open beam, but $2\%$ differences with MTW. In the result of the measurements of peripheral dose, it was shown that MTW was about $1\%$ higher than open field and EDW. The surface doses of $60^{\circ}$ MTW showed 10% lower than the others. We found that effective wedge factor of EDW had linear relationships according to Y jaw sizes and was independent of X jaw sizes and was independent of X jaw sizes and asymmetric Y jaw opening. In comparison with measured values and calculate values from Golden-STT based radiation treatment planning system (RTP system), it showed very good agreement within difference of $1\%$. It could be concluded that EDW is a very reliable and useful tool as a beam modification substitute for conventional MTW.

  • PDF

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF

Measurement and Assessment of Alpha Activity in Ground Air (지표공기중(地表空氣中)의 ${\alpha}$ 방사능측정(放射能測定) 및 해석(解析))

  • Jun, Jae-Shik;Myung, Dong-Bun
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.130-138
    • /
    • 1986
  • A study on the measurement of alpha activity in ground air has been carried out using CA 80-15 and LR 115-1 cellulose nitrate nuclear track detectors. The detection efficiency of the detectors were determined by making use of an $^{241}Am$ alpha source of $0.1{\mu}Ci$ in activity under a known geometrical arrangement. For the field measurement of alpha activity of emanated radon and its progeny in ground air two different radon cups were installed for a certain period of time in two neighbouring ground holes of about 15 cm in diameter and 45 cm in depth. Of the two radon cups one kept closed space during the detecting period, while the other kept open space with a hole enabling the air to ventilate. The etched tracks were read out by a microscope and the results obtained through statistical analysis were evaluated in terms of alpha activity per unit volume of air.

  • PDF

Linear Tapered Slot Rectifying Antenna for Portable UHF-Band RFID System (휴대용 UHF대역 RFID 시스템을 위한 선형 테이퍼드 슬롯 정류 안테나)

  • Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.368-371
    • /
    • 2020
  • In this paper, we propose a linear tapered slot rectifying antenna for a portable UHF-band RFID system. Since the proposed rectifying antenna does not use a dielectric substrate, the planar antenna is implemented with a thin metal thickness. The rectifier circuit converts input RF power into output DC voltage using a voltage doubler circuit based on two anti-parallel schottky diodes. The rectifying antenna is integrated by the voltage doubler circuit into a linear tapered slot antenna. For conjugate impedance matching of the rectifying circuit and the linear tapered slot antenna, the source-pull method was utilized by adjusting the angle of the tapered slot and the length of the antenna feed line. The proposed antenna prototype has been verified with the electrical and radiation characteristics through RF-DC conversion and far-field radiation test in open space measurement environment. Finally, the proposed antenna is realized to 0.23-wavelength (75 mm) and 0.18-wavelength (60 mm) at 915 MHz center frequency.

The Analysis of the Wideband T-shaped Microstripline-fed Slot Antenna with a Rectangular Stub (광대역성을 위한 장방형 스터브를 갖는 T-모양 급전선 마이크로스트립 슬롯 안테나의 해석)

  • 장용웅;윤종철;박익모;신철재
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.9
    • /
    • pp.13-19
    • /
    • 1998
  • It was shown that the bandwidth of T-shaped microstripline fed slot antenna is wider than many of the conventional feeding structures. In this paper, we proposed a new method of enhancing the bandwidth of T-shaped microstripline fed slot antenna with a shunt open stub, and analyzed this antenna by using the FDTD method. We have computed waves and electric field distribution in the time domain, and VSWR, input impedance and radiation pattern in the frequency domaim by Fourier transforming the time domain results. It was found that the bandwidth of this antenna depend on the position(L$_1$) and length(L$_2$) of a shunt open stub. When these parameters are L$_1$=30 mm and L$_2$=33mm, we obtained the maximum bandwidth at the center frequency of 2.3 GHz. From the computed results, the optimum antenna is designed and fabricated. The fractional bandwidth of this antenna was 53.9 %. The measured results were in relatively good accordance with computed values.

  • PDF