• Title/Summary/Keyword: open loop characteristics

Search Result 165, Processing Time 0.027 seconds

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

A Design of a 5 GHz Low Phase Noise Voltage Tuned Dielectric Resonator Oscillator Using Loop Group Delay (루프 군지연을 이용한 저위상 잡음 5 GHz 전압제어 유전체 공진기 발진기 설계)

  • Son, Beom-Ik;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.269-281
    • /
    • 2014
  • In this paper, a systematic design of a low phase noise voltage-tuned dielectric resonator oscillator(VTDRO) using loop group delay is proposed. Designed VTDRO is closed-loop type and consists of a cascade connection of a resonator, phase shifter, and amplifier. Firstly, a reference VTDRO is fabricated and its phase noise and electrical frequency tuning range are measured. Both the phase noise and electrical frequency tuning range depend on the loop group delay. Then, a required value of loop group delay for a new VTDRO with a low phase noise can be systematically computed. In addition, its phase noise and electrical frequency tuning range can be theoretically estimated using those obtained from the measurement of the reference VTDRO. When the loop group delay increases, the phase noise decreases and the electrical frequency tuning range also decreases. The former predominantly depends on the resonator structure. Therefore we propose a systematic design procedure of a resonator with high group delay characteristics. The measured loop group delay of the new VTDRO is about 700 nsec. The measured phase noise of the new VTDRO show a state-of-the-art performance of 154.5 dBc/Hz at 100 kHz frequency offset and electrical frequency tuning range of 448 kHz for a voltage change of 0~10V. The oscillation power is about 4.39 dBm.

Design and fabrication of a 300A class general-purpose current sensor (300A급 일반 산업용 전류센서의 설계 및 제작)

  • Park, Ju-Gyeong;Cha, Guee-Soo;Ku, Myung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current sensors are used widely in the fields of current control, monitoring, and measuring. They have become more popular with the increasing demand for smart grids in a power network, generation of renewable energy, electric cars, and hybrid cars. Although open loop Hall effect current sensors have merits, such as low cost, small size, and weight, they have low accuracy. This paper describes the design and fabrication of a 300A open loop current sensor that has high accuracy and temperature performance. The core of the current sensor was calculated numerically and the signal conditioning circuits were designed using circuit analysis software. The characteristics of the manufactured open loop current sensor of 300 A class was measured at currents up to 300 A. According to the test of the current sensor, the accuracy error and linearity error were 0.75% and 0.19%, respectively. When the temperature compensation was carried out with the relevant circuit, the temperature coefficients were less than $0.012%/^{\circ}C$ at temperatures between $-25^{\circ}C$ and $85^{\circ}C$.

A Study on the Estimation of Automatic Steering of Ships in Multi-directional Waves (다방향파중에서의 선박 자동조타 시스템의 평가 기법에 관한 연구)

  • 이경우;손경호;윤순동
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.1
    • /
    • pp.79-89
    • /
    • 1998
  • When an automatic course-keeping is concerned , as is quite popular in modern navigation, the closed-loop steering system consists of autopilot device, power unit(or telemotor unit), steering gear, magnetic or gyro compass and ship dynamics. In order to estimate steering system of ship in open seas, we need to know the characteristics of each component of the system and also to know the characteristics of disturbance to ship dynamics. Calculation methods of irrgular disturbances are based on the linear superposition principle. In this paper, for the purpose of evaluation of automatic steering of ships , the influences of linear control constants of autopilot on propulsive energy loss are investigated bya performance index is introduced from the viewpoint of energy saving. Numberical calculations are carried out for an are carrier and for a fishing boat in multi-directional waves.

  • PDF

Adaptive Control Method for a Feedforward Amplifier

  • Kang, Sang-Gee;Yi, Hui-Min;Hong, Sung-Yong
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.108-112
    • /
    • 2003
  • A feedforward amplifier, which is composed of several components, is an open loop system. Therefore, feedforward amplifiers are apt to deteriorate the performance according to the environmental changes even though the cancellation performance and the linearization bandwidth of feedforward systems are superior to other linearization methods. A control method is needed for maintaining the original performance of feedforward amplifiers or to keep the performance within a little error bounds. In this paper, an adaptive control method, which has a good convergence characteristic and is easy to implement, is suggested. The characteristics of the suggested control method compare with the characteristics of other control methods and the simulation results are presented.

  • PDF

Shift Characteristics Analysis and Smooth Shift for an Automatic Power Transmission

  • Jeong, Heon-Sul;Lee, Kyo-Ill
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.499-507
    • /
    • 2000
  • Smooth shift is one of the key issues in automatic power transmission control systems. However, the torque sensors are too expensive to be used in shift controllers on production vehicles. In order to provide a basic strategy for smooth shifting by using RPM sensors only and in order to accomplish the shift within a designated time, this paper studies detailed characteristics of the smooth shift for clutch-to-clutch shift mechanism. A desired trajectory of slip speed is proposed for smooth acceleration shift defined in this paper. Also the clutch torque needed to achieve this trajectory is derived, and it may be used as a open loop shift control law.

  • PDF

Implementation and Design of Wideband IFIU using Aperture Open Loop Resonator and Reversed Phase Technique (역 위상 기법과 Aperture를 갖는 개방형 루프 공진기를 사용한 광대역 IF 모듈 설계 및 제작)

  • 김영완
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.11
    • /
    • pp.17-23
    • /
    • 2004
  • The implementation and design of the wideband IFIU using aperture open loop resonator and reversed phase technique to reduce the local oscillator leakage signal was represented in this paper. The local oscillator leakage signal is generated in stage of frequency conversion, especially in frequency conversion of fully digital modulation signal close to DC signal. The leakage signal and spurious signals, which have effects on adjacent channel or in-band channel as interference signals, were reduced below -60 dBc for 45 Mbps and 155 Mbps IF interface units. The group delay for both IFIUs shows low ripple characteristics of 15 ns and 8 ns, respectively. Also, the amplitude ripple characteristic in 150 MHz bandwidth with L-band center frequency satisfies the required specification of 2 dB. The implemented IFIU provides the required specifications for wideband satellite communication system.

Trajectory Control of Excavator Actuators Using IMV (IMV를 이용한 굴착기 작업장치 궤적제어)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.45-54
    • /
    • 2020
  • The IMV is a combination of four two-way valve systems which replace a conventional four-way spool valve to improve efficiency mostly in excavator hydraulics. As the environmental regulations for construction equipment have tightened, some overseas advanced companies have released commercial excavators in which the MCV is implemented with the IMVs. Development of the IMV type MCV relies on the control algorithm as well as the robust performance of proportional flow control valves. In this study, the IMV controller was designed and verified with experiments for the excavator working unit, which determines the IMV mode of operation and the extent of the valve opening in consideration of the load conditions on hydraulic actuators. First, the open-loop controller was designed with a joystick command vs. a PSV reference current map comprising several control parameters in to compensate for the different flow characteristics and non-linearities of two-way flow control valves. Second, the closed-loop controller was designed with the PI control fed by the actuator displacement and outputs actuator percent effort equivalent to the operator's joystick command. Finally, the performance of the IMV type MCV was verified with the trajectory control of position references derived from the energy consumption test standard. Experimental results showed the control performance of the IMV developed in this study, and suggest that future studies to be conducted to advance technical progress.

On the Application of MIMO systems for railway environment (철도 환경에서의 MIMO시스템의 응용 방안)

  • Lee Cheol Jin;Hwang Hyun Chyeol;Cho Bong Kwan;Shin Seung Hoon;Kwak Kyung Sup
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.2 s.5
    • /
    • pp.9-17
    • /
    • 2004
  • In this paper, we examine the MIMO(Multiple Input Multiple Output) system in the point of mobile communication that is used for railway environment. First, under the radio environment, wireless channel characteristics are analyzed between moving train and base station, both assuming track side base stations and non-track side base stations. Next, the paper introduces the MIMO system which can be used to solve the problem of performance degradation in railway environment, and analyzes its performance in terms of channel capacity and diversity. We especially compares open-loop scheme with closed loop scheme at the diversity and analyses their performance according to antenna correlation. Finally, the we presents experimental result from the ESCORT project that was studied in railway environment with the MIMO system.

  • PDF

A Novel Controller for Electric Springs Based on Bode Diagram Optimization

  • Wang, Qingsong;Cheng, Ming;Jiang, Yunlei
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1396-1406
    • /
    • 2016
  • A novel controller design is presented for the recently proposed electric springs (ESs). The dynamic modeling is analyzed first, and the initial Bode diagram is derived from the s-domain transfer function in the open loop. The design objective is set according to the characteristics of a minimum phase system. Step-by-step optimizations of the Bode diagram are provided to illustrate the proposed controller, the design of which is different from the classical multistage leading/lagging design. The final controller is the accumulation of the transfer function at each step. With the controller and the recently proposed δ control, the critical load voltage can be regulated to follow the desired waveform precisely while the fluctuations and distortions of the input voltage are passed to the non-critical loads. Frequency responses at any point can be modified in the Bode diagram. The results of the modeling and controller design are validated via simulations. Hardware and software designs are provided. A digital phase locked loop is realized with the platform of a digital signal processor. The effectiveness of the proposed control is also validated by experimental results.