• Title/Summary/Keyword: open end assumption

Search Result 7, Processing Time 0.022 seconds

Analysis for Lubrication of the Piston Ring Considering Oil Transport (오일이송을 고려한 피스톤 링의 윤활 해석)

  • 이재선;한동철
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.51-58
    • /
    • 1998
  • This paper considers analysis of the lubrication between the piston ring and the cylinder liner. Piston ring lubrication analysis considering oil transport is important because oil consumption is an essential factor to design the piston assembly. To develop the lubrication analysis program for the piston ring, oil continuity condition and open-end boundary assumption are used for computational boundaries. Results show that oil continuity can be almost satisfied at any crank angle in and out of the piston ring clearance. Therefore the amount of oil consumption and the dynamic behavior of ring pack can be estimated using this algorithm. And it can be known that the effective width may be smaller than the full width of the piston ring, so oil starvation condition should be considered for the lubrication analysis of the piston ring.

Analysis of Ring Pack Lubrication

  • Lee, Jae-Seon;Han, Dong-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.9
    • /
    • pp.928-934
    • /
    • 2000
  • This paper describes a method developed for the simulation of ring pack lubrication characteristic in an internal combustion engine. In general, the quantity of oil supply for piston ring lubrication may be insufficient in filling the entire volume formed at the interference between the piston ring and the cylinder liner. Thus the oil starvation condition should be considered in analyzing piston ring lubrication. In order to reasonably estimate the amount of oil left over on the cylinder liner, the flow rate at the posterior portion of the interface should be calculated with an adequate boundary condition that confirms flow continuity condition. In this analysis, oil starvation and open-end boundary conditions are considered at the inlet and outlet of the piston rings. The lubrication characteristic of each piston ring is obtained by an iterative method with sequential steps. It is revealed that piston rings are operated under oil starvation in most operating cycles and the result under these conditions are quite different from that with the fully-flooded assumption.

  • PDF

Analysis for Lubrication of the Piston Ring Considering Oil Transport-Examples (오일이송을 고려한 피스톤 링의 윤활 해석-예제)

  • 이재선;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.358-364
    • /
    • 1998
  • Lubricational characteristics at the interface between the piston ring and the cylinder liner are considered in this paper. To verify that surface shape and operating conditions of the engine can affect the state of lubrication, the changes of the minimum film thickness and friction force are calculated with various conditions. Oil starvation and open-end boundary condition are used to determine computational boundaries as reported on previous paper for lubrication analysis for the piston ring. From this analysis, it can be found that lubricational characteristics are seriously affected by degree of oil starvation, surface shape and operating conditions.

  • PDF

Transient Response of Optically-Controlled Microwave Pulse through an Open-Ended Microstrip Lines

  • Kim, Jin-S.;Kim, Yong-K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1187-1190
    • /
    • 2004
  • In this paper we analyze the reflection characteristics of a dielectric microstrip line with an open-end termination containing optically induced plasma region, which are analyzed by the assumption that the plasma is distributed homogeneously in the laser illumination. The characteristics impedances resulting from the presence of plasma are evaluated the transmission line model. To estimate theoretically the characteristic response of same systems in the time domain, the Fourier transformation method is evaluated. The reflection characteristics of time response in microwave systems have been calculated.

  • PDF

Analysis of Ring Pack Lubrication (다중 피스톤 링계의 피스톤 링 윤활 해석)

  • 이재선;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.232-239
    • /
    • 1999
  • Generally quantity of supply oil for piston ring lubrication in an internal combustion engine may be insufficient to fill the entire volume formed in the clearance between piston ring and cylinder liner. Thus oil starvation condition should be considered for the analysis of piston ring lubrication. In order to reasonably estimate amount of oil left on the cylinder liner, adequate boundary condition should be adapted for the analysis of ring pack lubrication. In this analysis of ring pack lubrication of an internal combustion engine, oil starvation and open-end boundary conditions are considered at inlet and outlet of piston rings. It is revealed that piston rings are operated under oil starvation in most operating cycle and the result with these conditions are quite different from that with fully-flooded assumption.

  • PDF

Analysis of Ring Pack Lubrication Considering Oil Transport (오일 이송을 고려한 다중 피스톤 링계의 피스톤 링 윤활 해석)

  • 이재선;한동철
    • Tribology and Lubricants
    • /
    • v.15 no.3
    • /
    • pp.233-239
    • /
    • 1999
  • Generally quantity of supply oil for piston ring lubrication in an internal combustion engine may be insufficient to fill the entire volume formed in the clearance between piston ring and cylinder liner. Thus oil starvation condition should be considered for the analysis of piston ring lubrication. In order to reasonably estimate amount of oil left on the cylinder liner, adequate boundary condition should be adapted for the analysis of ring pack lubrication. In this analysis of ring pack lubrication of an internal combustion engine, oil starvation and open-end boundary conditions are considered at inlet and outlet of piston rings. It is revealed that piston rings are operated under oil starvation in most operating cycle and the result with these conditions are quite different from that with fully-flooded assumption.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.