• Title/Summary/Keyword: oneM2M standards

Search Result 148, Processing Time 0.035 seconds

Correlation between the Geographical-name and Scale of Space Surrounded with Hills - Focused on Jinan-gun in Jeollabukdo - (지명과 지형적 위요(圍繞) 및 공간규모 인식의 관계 - 전북 진안군을 중심으로 -)

  • Lee, Jin-Dong;Kim, Jung-Kyu;Jung, Tae-Yeol;Kim, Yu-Ill
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.1
    • /
    • pp.81-92
    • /
    • 2010
  • The purpose of this study is to find one of the standard scales of outside space. Fortunately, Korea has interesting old geographical name representing the environment where people feel comfortable by being enclosed by hills or mountains like in a room. The name of Chinese letter "谷" meaning valley is enunciated as "Gog", and Korean native equivalent word is "Sil." We thought we can find the standards of scale of the villages with name that ends with "Gog" or "Sil" by examining the scale of the village of the certain geographical name. We could collect 33 village's geographical names in Jin An Gun area, examined the scale, and considered the results from various aspects. The main conclusions are following: 1) Almost of the 33 villages with geographical names of "Gog", or "Sil" were surrounded by the hills of mountains, and the scales of the spaces surrounded were roughly 10~25ha. 2) Our ancestors felt comfortable be being enclosed with hills or mountains like in a room, and they have recognized the certain scale of the enclosed spaces. 3) After converting the 33 areas into squares for convenience, the scales of the spaces with the geographical name of "Gog" or "Sil" were roughly $300m{\times}300m{\sim}500m{\times}500m$.

An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas (헬륨을 이용한 열유속센서 검정방법의 실험적 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF

A Survey on the Actual State of Laboratory Facilities and Equipments at Nursing Schools (간호교육기관의 실험실습설비 보유실태 조사)

  • Lim, N.Y.;Lee, S.O.;Suh, M.J.;Kim, H.S.;Kim, M.S.;Oh, K.O.
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.108-117
    • /
    • 1997
  • This study was carried out to examine the standards for evaluation of laboratory facilities and equipment. These constitute the most important yet vulnerable area of our system of higher education among the six school evaluation categories provided by the Korean Council for University Education. To obtain data on the present situation of holdings and management of laboratory facilities and equipment at nursing schools in Korea, questionnaires were prepared by members of a special committee of the Korea Nursing Education Society on the basis of the Standards for University Laboratory Facilities and Equipment issued by the Ministry of Education. The questionnaires were sent to nursing schools across the nation by mail on October 4, 1995. 39 institutions completed and returned the questionnaires by mail by December 31 of the same year. The results of the analysis of the survey were as follows: 1. The Physical Environment of Laboratories According to the results of investigation of 14 nursing departments at four-year colleges, laboratories vary in size ranging from 24 to 274.91 pyeong ($1{\;}pyeong{\;}={\;}3.3m^2).$. The average number of students in a laboratory class was 46.93 at four-year colleges, while the number ranged from 40 to 240 in junior colleges. The average floor space of laboratories at junior colleges, however, was almost the same as those, of laboratories at four-year colleges. 2. The Actual State of Laboratory Facilities and Equipment Laboratory equipment possessed by nursing schools at colleges and universities showed a very wide distribution by type, but most of it does not meet government standards according to applicable regulations while some types of equipment are in excess supply. The same is true of junior colleges. where laboratory equipment should meet a different set of government standards specifically established for junior colleges. Closer investigation is called for with regard to those types of equipment which are in short supply in more than 80 percent of colleges and universities. As for the types of equipment in excess supply, investigation should be carried out to determine whether they are really needed in large quantities or should be installed. In many cases, it would appear that unnecessary equipment is procured, even if it is already obsolete, merely for the sake of holding a seemingly impressive armamentarium. 3. Basic Science Laboratory Equipment Among the 39 institutions, five four-year colleges were found to possess equipment for basic science. Only one type of essential equipment, tele-thermometers, and only two types of recommended equipment, rotators and dip chambers, were installed in sufficient numbers to meet the standards. All junior colleges failed to meet the standards in all of equipment categories. Overall, nursing schools at all of the various institutions were found to be below per in terms of laboratory equipment. 4. Required Equipment In response to the question concerning which type of equipment was most needed and not currently in possession, cardiopulmonary resuscitation (CPR) machines and electrocardiogram (ECG) monitors topped the list with four respondents each, followed by measuring equipment. 5. Management of Laboratory Equipment According to the survey, the professors in charge of clinical training and teaching assistants are responsible for management of the laboratory at nursing schools at all colleges and universities, whereas the chief of the general affairs section or chairman of the nursing department manages the laboratory at junior colleges. This suggests that the administrative systems are more or less different. According to the above results, laboratory training could be defined as a process by which nursing students pick up many of the nursing skills necessary to become fully qualified nurses. Laboratory training should therefore be carefully planned to provide students with high levels of hands-on experience so that they can effectively handle problems and emergencies in actual situations. All nursing students should therefore be thoroughly drilled and given as much on-the-job experience as possible. In this regard, there is clearly a need to update the equipment criteria as demanded by society's present situation rather than just filling laboratory equipment quotas according to the current criteria.

  • PDF

Establishing Quantitative Standards for Residual Alkaline Phosphatase in Pasteurized Milk

  • Kim, Dong-Hyeon;Chon, Jung-Whan;Lim, Jong-Soo;Kim, Hong-Seok;Kang, Il-Byeong;Jeong, Dana;Song, Kwang-Young;Kim, Hyunsook;Kim, Kwang-Yup;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.36 no.2
    • /
    • pp.194-197
    • /
    • 2016
  • The alkaline phosphatase (ALP) assay is a rapid and convenient method for verifying milk pasteurization. Since colorimetric ALP assays rely on subjective visual assessments, their results are especially unreliable near the detection limits. In this study, we attempted to establish quantitative criteria for residual ALP in milk by using a more objective method based on spectrophotometric measurements. Raw milk was heat-treated for 0, 10, 20, 30, and 40 min and then subjected to ALP assays. The quantitative criteria for residual ALP in the milk was determined as 2 μg phenol/mL of milk, which is just above the ALP value of milk samples heat-treated for 30 min. These newly proposed methodology and criteria could facilitate the microbiological quality control of milk.

The external and internal morphological standard of original plants and herbal states in 2 kinds of Arisaematis Rhizoma (2종 천남성(天南星)의 외부(外部) 및 내부형태(內部形態)에 대한 연구)

  • Kang Jun-Hyug;Yun Ju-Bong;Ju Young-Sung
    • Herbal Formula Science
    • /
    • v.11 no.2
    • /
    • pp.213-232
    • /
    • 2003
  • Objectives : This study was designed to establish a characteristic discrimination of internal and external morphological standard of original plants and herbal states in Arisaema amurense var. serratum $N_{AKAI}$ and A. amurense $M_{AXIM}.$. Methods : In this studies, the external-internal morphological standards were determined by using stereoscope and butanol series. Results : 1. In the external shape of original plant, Arisaema amurense var. serratum $N_{AKAI}$ has high stem, an oval-elliptic leaflet and a serrate leaf margin. But A. amurense $M_{AXIM}$ has a relatively low stem, an upside oval leaflet and no serrate leaf margin. 2. On the herbs character of original plant, Arisaema amurense var. serratum $N_{AKAI}$ is small in height and diameter, but A. amurense $M_{AXIM}$ is relatively large in height and diameter. 3. On the gathered herbs character of original plant, the section of Arisaema amurense var. serratum $N_{AKAI}$ is brightly white, easily spilt and strong scent. But the section of A. amurense $M_{AXIM}$ is thin yellowish brown, not easily spilt and weak scent. Also the grade of gathered herbs, both can be classified by diameter and external scent. 4. In the current herbs character, Korean and Sichuan Province products are irregullar shape and have no scent, Jilin Province products are regular shape. Also, Guangxi Province products are small size and concave in one side, Hebei Province products are irregular size and shape. 5. In internal shape of original plant, epidermal cell of Arisaema amurense var. serratum is very tight. With the except of micro difference in parenchyma cell of cortex, on the whole there are nearly no differences with A. amurense $M_{AXIM}.$ Also, samely in the internal shape, according to collecting sites, epidermis exhibits a lot layer in curving state and secreting duct is developed and vascular bundle and exists between parenchyma cell of cortex. Conclusion : In the future, additional study is needed to distinguish herb and effect between same genus-degree of relatedness.

  • PDF

Creating Cultural Cluster through Reuse of Industrial Heritage in the Inner city - Case Studies of M50, BankART1929, ARTPlatform - (구도심 내 근대산업유산의 재생을 통한 문화클러스터 조성에 관한 연구 - M50, 뱅크아트1929, 아트플랫폼 사례를 중심으로 -)

  • Park, So-Yeon;Lee, Kyung-Hoon
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.6
    • /
    • pp.192-201
    • /
    • 2015
  • This research aims to find planning issues on reuse of an industrial heritage as a cultural cluster and to suggest planning factors which can be referred when designing the similar cases. Analysis standards were formed through reviewing of precedent literatures, and the selected cases(i.e Shanghai M50, Yokohama BankART1929, and Incheon ArtPlatform) were analyzed to identify both physical and nonphysical planning characteristics. By combining analyses, the following results were obtained; (1) The demand and supply of the arts coexist in one place, and the studios and galleries are designed with high ceilings; (2) The regional and historical characteristics are revealed from preserving major architectural elements of previous buildings, and open spaces are provided to promote a variety of activities for local residents; (3) Various strategies to overcome disadvantage in location are developed, and the concepts of design can be easily recognized by buildings' exterior as the reused industrial heritage and the cultural cluster; (4) Diverse supports for artists make it possible to gather many competent artists, and the cooperative networks among artists play a pivotal role in the development of cultural cluster; (5) The cluster runs educational programs reflecting the needs of local residents, and builds a strong relationship with the local community by supporting regional art industry or developing linked programs; (6) The cluster serves various functions such as cafes, pubs, restaurants, art shops, and bookstores, and hosts appealing events and festivals to attract many people even who are not interested in arts.

Assessment of Pollution Levels in the Jangsungcheon Watershed Using Load Duration Curves and Analysis of the Causes

  • Cho, Sohyun;Bak, Jonghun;Lee, Yeong Jae;Kim, Kyunghyun;Jung, Kang Young
    • Journal of Environmental Science International
    • /
    • v.28 no.10
    • /
    • pp.873-885
    • /
    • 2019
  • In this study, a load duration curve was applied to the Jangseongcheon, one of the tributaries of the Yeongsan River, to assess whether the target water quality was achieved. In addition, pollution of the water body was investigated to develop and suggest the optimal management time with respect to polluted flow sections and monthly conditions. The average flow rates of sections JS1 and JS2 were $0.25m^3/s$ and $1.08m^3/s$, respectively. The BOD and T-P for water-quality standards at JS1 were rated at II, whereas the COD and TOC were rated at III, thus indicating a fair level of water quality. By contrast, the BOD at JS2 was rated at III, the T-P at IV, and the TOC at V, indicating poor water quality in this section. The load duration curve was plotted using the actual flow data measured in eight-day intervals for eight years from 2011 to 2018 at locations JS1 and JS2 in the Jangsungcheon Basin. In an assessment using the load duration curve on whether the target water quality was met at location JS1, all of the water quality parameters (BOD, COD, TOC, T-N, T-P, and SS) satisfied the target water quality. By contrast, at location JS2, parameters COD, TOC, T-N, and T-P exceeded target values by more than 50%, indicating the target water quality was not met. The discharge loads of locations JS1 and JS2 were analyzed to identify the reasons the target water quality was exceeded. Results revealed that the land system contributed considerably. Furthermore, the discharge load of JS2 accounted for more than 80% of the load on the entire basin, excluding that of JS1. Therefore, the best method for restraining the inflow of pollutants into the stream near location JS2 must be applied to manage the water quality of the Jangsungcheon.

Inhibition of Jurkat T Cell Proliferation by Active Components of Rumex japonicus Roots Via Induced Mitochondrial Damage and Apoptosis Promotion

  • Qiu, Yinda;Li, Aoding;Lee, Jina;Lee, Jeong Eun;Lee, Eun-Woo;Cho, Namki;Yoo, Hee Min
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.12
    • /
    • pp.1885-1895
    • /
    • 2020
  • Rumex japonicus Houtt (RJH) is a valuable plant used in traditional medicine to treat several diseases, such as scabies and jaundice. In this study, Jurkat cell growth inhibitory extracts of R. japonicus roots were subjected to bioassay-guided fractionation, resulting in the isolation of three naphthalene derivatives (3-5) along with one anthraquinone (6) and two phenolic compounds (1 and 2). Among these compounds, 2-methoxystypandrone (5) exhibited potent anti-proliferative effects on Jurkat cells. Analysis by flow cytometry confirmed that 2-methoxystypandrone (5) could significantly reduce mitochondrial membrane potential and promote increased levels of mitochondrial reactive oxygen species (ROS), suggesting a strong mitochondrial depolarization effect. Real-time quantitative polymerase chain reaction (qPCR) analysis was also performed, and the results revealed that the accumulation of ROS was caused by reduced mRNA expression levels of heme oxygenase (HO-1), catalase (CAT), glutathione peroxidase (GPx), and superoxide dismutase (SOD). In addition, 2-methoxystypandrone (5) triggered strong apoptosis that was mediated by the arrest of the G0/G1 phase of the cell cycle. Furthermore, 2-methoxystypandrone (5) downregulated p-IκB-α, p-NF-κB p65, Bcl2, and Bcl-xl and upregulated BAX proteins. Taken together, these findings revealed that 2-methoxystypandrone (5) isolated from RJH could potentially serve as an early lead compound for leukemia treatment involving intracellular signaling by increasing mitochondrial ROS and exerting anti-proliferative effects.

The need for mechanization in todays canal building program in korea and overseas (수로의 기계화 시공의 필요성)

  • Ha, Gordon P.wkins
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.2
    • /
    • pp.21-27
    • /
    • 1979
  • Canal construction is not the only area in which mechanization has advanced with great strides. All phases of the construction industry, including earthmoving, land clearing and levelling, road construction, and drainage and water control projects, have benefited from today's technological advancements. Lasers, an excellant example of advanced technology, have been refined for use as guidance systems for construction machinery, increasing accuracy and the speed of operation. The use of explosives by contractors is becoming more commonplace. One of the most valuable modern tools available today is the two-way radio. On today's sophisticated projects a single machine being down can frequently stop the progress of the entire project, delaying hundreds of men and machines from completing their assigned work for the day. The use of two-way radios in all the pickups and cars being used on a project facilitates communication so that emergency repairs can be effected immediately, and costly down time on any project can be reduced to a minimum. Not every construction project is suitable to mechanization. However, on the majority of projects mechanization has a great deal to offer the Korean contractor, and all contractors, in savings of time and money. Each and every project being considered by a contractor, should be closely examined for the most effective and efficient machinery application available. The International Commission on Irrigation and Drainage (ICID) has formed a committee on construction techniques being used in canal construction today. Two publications are now available describing the advances made in recent years. Standards for construction have been established for mechanized systems and this information is being distributed worldwide.

  • PDF

토양 및 지하수 Investigation 과 Remediation에 대한 현장적용

  • Wallner, Heinz
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.44-63
    • /
    • 2000
  • Situated close to Heathrow Airport, and adjacent to the M4 and M25 Motorways, the site at Axis Park is considered a prime location for business in the UK. In consequnce two of the UK's major property development companies, MEPC and Redrew Homes sought the expertise of Intergeo to remediate the contaminated former industrial site prior to its development. Industrial use of the twenty-six hectare site, started in 1936, when Hawker Aircraft commence aircraft manufacture. In 1963 the Firestone Tyre and Rubber Company purchased part of the site. Ford commenced vehicle production at the site in the mid-1970's and production was continued by Iveco Ford from 1986 to the plant's decommissioning in 1997. Geologically the site is underlain by sand and gravel, deposited in prehistory by the River Thames, with London Clay at around 6m depth. The level of groundwater fluctuates seasonally at around 2.5m depth, moving slowly southwest towards local streams and watercourses. A phased investigation of the site was undertaken, which culminated in the extensive site investigation undertaken by Intergeo in 1998. In total 50 boreholes, 90 probeholes and 60 trial pits were used to investigate the site and around 4000 solid and 1300 liquid samples were tested in the laboratory for chemical substances. The investigations identified total petroleum hydrocarbons in the soil up to 25, 000mg/kg. Diesel oil, with some lubricating oil were the main components. Volatile organic compounds were identified in the groundwater in excess of 10mg/l. Specific substances included trichloromethane, trichloromethane and tetrachloroethene. Both the oil and volatile compounds were widely spread across the site, The specific substances identified could be traced back to industrial processes used at one or other dates in the sites history Slightly elevated levels of toxic metals and polycyclic aromatic hydrocarbons were also identified locally. Prior to remediation of the site and throughout its progress, extensive liaison with the regulatory authorities and the client's professional representatives was required. In addition to meetings, numerous technical documents detailing methods and health and safety issues were required in order to comply with UK environmental and safety legislation. After initially considering a range of options to undertake remediation, the following three main techniques were selected: ex-situ bioremediation of hydrocarbon contaminated soils, skimming of free floating hydrocarbon product from the water surface at wells and excavations and air stripping of volatile organic compounds from groundwater recovered from wells. The achievements were as follows: 1) 350, 000m3 of soil was excavated and 112, 000m3 of sand and gravel was processed to remove gravel and cobble sized particles; 2) 53, 000m3 of hydrocarbon contaminated soil was bioremediated in windrows ; 3) 7000m3 of groundwater was processed by skimming to remove free floating Product; 4) 196, 000m3 of groundwater was Processed by air stripping to remove volatile organic compounds. Only 1000m3 of soil left the site for disposal in licensed waste facilities Given the costs of disposal in the UK, the selected methods represented a considerable cost saving to the Clients. All other soil was engineered back into the ground to a precise geotechnical specification. The following objective levels were achieved across the site 1) By a Risk Based Corrective Action (RBCA) methodology it was demonstrated that soil with less that 1000mg/kg total petroleum hydrocarbons did not pose a hazard to health or water resources and therefore, could remain insitu; 2) Soils destined for the residential areas of the site were remediated to 250mg/kg total petroleum hydrocarbons; in the industrial areas 500mg/kg was proven acceptable. 3) Hydrocarbons in groundwater were remediated to below the Dutch Intervegtion Level of 0.6mg/1; 4) Volatile organic compounds/BTEX group substances were reduced to below the Dutch Intervention Levels; 5) Polycyclic aromatic hydrocarbons and metals were below Inter-departmental Committee for the Redevelopment of Contaminated Land guideline levels for intended enduse. In order to verify the qualify of the work 1500 chemical test results were submitted for the purpose of validation. Quality assurance checks were undertaken by independent consultants and at an independent laboratory selected by Intergeo. Long term monitoring of water quality was undertaken for a period of one year after remediation work had been completed. Both the regulatory authorities and Clients representatives endorsed the quality of remediation now completed at the site. Subsequent to completion of the remediation work Redrew Homes constructed a prestige housing development. The properties at "Belvedere Place" retailed at premium prices. On the MEPC site the Post Office, amongst others, has located a major sorting office for the London area. Exceptionally high standards of remediation, control and documentation were a requirement for the work undertaken here.aken here.

  • PDF