• Title/Summary/Keyword: oneM2M standards

Search Result 148, Processing Time 0.031 seconds

Design and Characterization of Low-noise Dewar for High-sensitivity SQUID Operation (고감도 SQUID 냉각을 위한 저잡음 듀아의 설계 및 특성 조사)

  • Yu, K.K.;Lee, Y.H.;Kim, K.;Kwon, H.;Kim, J.M.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.152-157
    • /
    • 2010
  • We have fabricated the low noise liquid helium(LHe) dewar with a different shape of thermal shield to apply the 64-channel SQUID(Superconducting Quantum Interference Device) gradiometer. The first shape of thermal shield was made of an aluminum plate with a wide width of 100 mm slit and the other shape was modified with a narrow width of 20 mm slit. The two types of dewars were estimated by comparing the thermal noise and the signal-to-noise ratio(SNR) of magnetocardiography(MCG) using the $1^{st}$ order SQUID gradiometer system cooled each dewar. The white noise was different as a point of the dewar. The noise was increased as close as the edge of dewar, and also increased at the thermal shield with the more wide width slit. The white noise of the dewar with thermal shield of 100 mm slit was 6.5 fT/$Hz^{1/2}$ at the center of dewar and 25 fT/$Hz^{1/2}$ at the edge, and the white noise of the other one was 3.5 - 7 fT/$Hz^{1/2}$. We measured the MCG using 64-channel SQUID gradiometer cooled at each LHe dewar and compared the SNR of MCG signal. The SNR was improved of 10 times at the LHe dewar with a modified thermal shield.

A Study on Developing the Optimal Sizing System for Ready-to-wear - Based on Elementary School Girls - (기성복의 최적 사이즈 시스템 개발을 위한 연구 - 학령기 여아를 중심으로 -)

  • Kim Ran-do;Lee Sang-youl;Kim Seon-young;Nam Yun-ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.8 s.145
    • /
    • pp.1102-1113
    • /
    • 2005
  • The propose of this study is to develop the optimal sizing system of ready-to-wear f3r elementary school girls using a newly invented statistical technique. The body measurements was classified by the method that equalizes the distribution of the subjects using the probability density function, to theoretically systemize a method to determine a size range of ready-to-wear for elementary school girls between 6 to 12 years old. The statistical method were 1) The total of 11 height groups, which size interval from one another is 6 cm that is an average height gap between each age. 2) In order to determine an approximate figure (m ${\times}$ n) to establish the appropriate sizes far each height group that fit to the combinations of bust and hip girth, which based on their means and standard deviations on the probability density curve to produce the standard normal distribution. 3) m and n were aligned by 4cm -the grading increments used for patterns making- and determined the size ranges by confirming the approximate figures of m and n. 4) The representative values were determined by an area ratio calculated by dividing the area determined from the range of bust and hip girth with the representative value. Considering the characteristics of subjects' distribution, the area ratios was used. 5) Weight was calculated by seeking a growth exponent for each age and multiplying it by the number of girls that fit to each size range. As sections that show the highest weight are more likely sought by the consumers, these sections were determined as the optimal size standards. 6) This optimal sizing system consists of sizes determined by the optimal size standards and its sizes are marked with height, bust and hip girth.

4-Channel 3.2/6.4-Gbps Dual-rate Transmitter (채널 3.2/6.4 Gbps 이중 전송률 송신기)

  • Kim, Du-Ho;Choi, Woo-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.37-43
    • /
    • 2010
  • As the speed of A/V streaming, the transmission-speed requirement of serial link is continuously increasing. Consequently, commercial standards, which are released previously, are increasing transmission speed in their newly-updated versions. The flexibility between previous and updated versions is very important requirement, therefore, the transceiver which can operates at more than one data rate is important market demand. This paper demonstrates 4-channel 3.2/ 6.4 Gbps transmitter, which is capable of selecting 1, 1.5, 2, and 3 times of pre-emphasis and 200, 300, 400, and 600 mVdiff,p2p of output swing. The prototype chip was fabricated using $0.13{\mu}m$ CMOS process. Its performances are verified on PCB using COB packaging.

Expression of Cu/Zn SOD according to H2O2 in Hepatoma cell line (Hepatoma 세포주에서 H2O2 처리에 의한 Cu/Zn SOD의 발현)

  • Kim, Young-Min;Seo, Won-Sook
    • Journal of Life Science
    • /
    • v.17 no.2 s.82
    • /
    • pp.230-234
    • /
    • 2007
  • Oxygen is required for many important aerobic cellular reactions, it may undergo electrontransfer reactions, which generate highly reactive membrane-toxic intermediates (reactive oxygen species, ROS), such as hydrogen peroxide, singlet oxygen, superoxide radical, hydroxyl radical, hydroperoxyl radical, hydroxy ion. Various mechanisms are available to protect cells against damage caused by oxidative free radicals, including scavenging enzyme systems such as superoxide dismutase (SOD), catalase (CAT), and glutathione peroxidase (GPx). This antioxidant defense system is a very complex and finely tuned system consisting of enzymes capable of detoxifying oxygen radicals as well as low molecular weight antioxidants. In addition, repair and turnover processes help to minimize subcellular damage resulting from free radical attack. $H_2O_2$,one of the major ROS, is produced at a high rate as a product of normal aerobic metabolism. The primary cellular enzymatic defense systems against $H_2O_2$ are the glutathione redox cycle and catalase. From Northern blot analysis of total RNAs from cultured cell with $H_2O_2$ treatment, various results were obtained. Expression of Cu/Zn SOD decreased when cell passage increased, but the level of the Cu/Zn SOD was scarcely expressed in 35 passage.

Preliminary Shielding Analysis of the Concrete Cask for Spent Nuclear Fuel Under Dry Storage Conditions (건식저장조건의 사용후핵연료 콘크리트 저장용기 예비 방사선 차폐 평가)

  • Kim, Tae-Man;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.391-402
    • /
    • 2017
  • The Korea Radioactive Waste Agency (KORAD) has developed a concrete cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. During long-term storage of spent nuclear fuel in concrete casks kept in dry conditions, the integrity of the concrete cask and spent nuclear fuel must be maintained. In addition, the radiation dose rate must not exceed the storage facility's design standards. A suitable shielding design for radiation protection must be in place for the dry storage facilities of spent nuclear fuel under normal and accident conditions. Evaluation results show that the appropriate distance to the annual dose rate of 0.25 mSv for ordinary citizens is approximately 230 m. For a $2{\times}10$ arrangement within storage facilities, rollover accidents are assumed to have occurred while transferring one additional storage cask, with the bottom of the cask facing the controlled area boundary. The dose rates of 12.81 and 1.28 mSv were calculated at 100 m and 230 m from the outermost cask in the $2{\times}10$ arrangement. Therefore, a spent nuclear fuel concrete cask and storage facilities maintain radiological safety if the distance to the appropriately assessed controlled area boundary is ensured. In the future, the results of this study will be useful for the design and operation of nuclear power plant on-site storage or intermediate storage facilities based on the spent fuel management strategy.

A Study on Worker Exposure to Chromium and Degreasing Solvent at Eleetroplating Operation in Small Industry in Korea (우리나라 중소기업 도금공정 근로자의 크롬 및 세척제 폭로에 관한 연구)

  • Paik, Nam Won;Zong, Moon Shik;Lee, Hong Keun;Yun, Chung Ski;Ceong, Hoe Kyeong;Lee, Kyeong Hee;Lee, Na Roo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.110-126
    • /
    • 1993
  • Worker exposures to total chromium, hexavalent chromium (VI), sulfuric acid and alkaline dust at electroplating operations and worker exposures to trichloroethylene (TCE) and methyl chloroform (MCM) at degreasing operations in eleven small industrial plants were evaluated. Appropriate local exhaust ventilation systems for both operations were designed and recommended. Results of the study are summarized as follows ; 1. Out of 134 measurements for airborne hexavalent chromium concentrations, seven were exceeding the Korean occupational health standard of $50{\mu}g/m^3$ and 45 were exceeding the NIOSH standard of $1{\mu}g/m^3$. With an exception of one measurement, concentrations of total chromium were below the Korean standard of $500{\mu}g/m^3$. 2. Worker exposures to chromium were closely related to the existing control methods at the electroplating operations. Local exhaust systems, partial coverage of the tank surface, and antifoaming agents on liquid surface were adopted as control methods. 3. With an exception of one sample, airborne concentrations of sulfuric acid and alkaline dusts were below the applicable occupational heatlth standards. 4. Three plants indicated that airborne concentrations of TCE and MCM were exceeding the Korean standards. Other plants showed lower concentrations than the standards. It should be noted that generally, the activities and workloads on the day of surveys were less than normal. 5. Since the most existing ventilation systems did not satisfy the ACGIH criteria, the ventilation systems should be improved. Some examples for designing appropriate ventilation systems are presented.

  • PDF

A Guideline for the Location of Bus Stop Type considering the Interval Distance of Bus Stops and Crosswalks at Mid-Block (Mid-Block상의 버스정류장과 횡단보도 이격거리를 고려한 버스정류장 배치형태 기준 연구)

  • Lee, Su-Beom;Gang, Tae-Uk;Gang, Dong-Su;Kim, Jang-Uk
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.2
    • /
    • pp.123-133
    • /
    • 2010
  • The national standards for the installation of pedestrian crosswalks prohibits installation of crosswalks within 200 meters of nearby overpasses, underpasses, or crosswalks. In case the exceptional installation is required, the feasibility study is to be thoroughly conducted by the local police agency. However, it is an undeniable fact that the specific installation standards for optimal types and locations of crosswalks are not yet to be established. This paper examines the development of traffic accident prediction model applicable to different types and locations of bus stops(type A and type B) at mid-block intersections. Furthermore, it develops the poisson regression model which sets the "number of traffic accidents" and "traffic accident severity" as dependent variables, while using "traffic volumes", "pedestrian traffic volumes" and "the distance between crosswalks and bus stops" as independent variables. According to the traffic accident prediction model applicable to the type A bus stop location, the traffic accident severity increases relative to the number of traffic volumes, the number of pedestrian traffic volumes, and the distance between crosswalks and bus stops. In case of the type B bus stop model, the further the bus stop is from crosswalks, the number of traffic accidents decreases while it increases when traffic volumes and pedestrian traffic volumes increase. Therefore, it is reasonable to state that the bus stop design which minimizes the traffic accidents is the type C design, which is the one in combination of type A and type B, and the optimal distance is found to be 65 meters. In case of the type A design and the type B design, the optimal distances are found to be within range 60~70meters.

The Study of Pressure Vacuum Measurement Techniques Using Ultrasonic Acoustic Impedance Transducers (초음파 음향임피던스 변환기를 이용한 저압 저진공 측정기술 연구)

  • Hong, S.S.;Shin, Y.H.;Cho, S.H.;Ahn, B.Y.;Lim, J.Y.;Choi, I.M.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.319-325
    • /
    • 2010
  • Pressure vacuum measurement technique using acoustic impedance change of ultrasonic transducers was studied. The sensor has been setup using two air-coupled ultrasonic transducers, one as a transmitter and the other as a receiver, and put it into vacuum chamber and measured pressure versus ultrasonic amplitude. The result confirms that the standard deviations of four repeat measurements were from 0.0093 to 0.3325 at pressure 6.66 kPa to 202.65 kPa(about two atmosphere), and the relative percents were 0.018% and 0.164% at pressure 133.32 kPa and 202.65 kPa, respectively.

Management Strategy of Indoor Hazardous Chemicals (실내.외 통합 모델링 및 인체 위해성 평가를 통한 실내 유해화학물질의 관리 전략)

  • Shin, Yong-Seung;Lim, Hye-Sook
    • Journal of Environmental Policy
    • /
    • v.7 no.2
    • /
    • pp.67-90
    • /
    • 2008
  • The purpose of this study is to develop indoor air quality management strategies regarding indoor air pollutants while considering various factors affecting indoor pollutants concentration. The Integrated Indoor Air Quality model(IIAQ) developed by Seoul National University is used for this study. The IIAQ model is a tool that can provide an integrated view to indoor environmental pollution by simulating suggested scenarios. The results of the modeling are used to assess health risk. The concentrations that are used for the risk characterization are weighted concentrations based on the period of time in each place and existing Indoor Air Quality(IAQ) standards. The estimated concentration of toluene and formaldehyde for 10 years through the IIAQ model was 207.3 $ug/m^3$ and 36.4 $ug/m^3$ in indoors, and 55.9 $ug/m^3$ and 8.62 $ug/m^3$ in outdoors. These concentrations are lower than the existing IAQ standards. The estimated carcinogenic risk of formaldehyde is up to 1.05E-03 for the adult male group and exceeds 1E-06 for all receptor groups. This value means that cancer could affect one person out of 1000. The estimated non-carcinogenic risk of toluene was lower than 1, which means that there was no serious non- carcinogenic risk. The result of modeling shows that using low emitting indoor sources is the most effective strategy for both formaldehyde and toluene. This risk assessment suggests that the total exposure levels of existing IAQ standards may cause serious carcinogenic risk. In order to avoid uncontrolled risk, it is suggested that the current IAQ standards should be adjusted by taking into account the total amount of exposure from all exposure pathways from indoor and outdoor sources.

  • PDF

A Survey of the Air Quality in Underground Environment (지하환경의 대기오염물질 규제에 관한 조사연구)

  • Lee M. H.;Han E. J.;Shin C. K.;Chung H. D.;Han J. K.
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.47-58
    • /
    • 1986
  • The underground living spaces have become one of the major environment of this decade in urban area. This study was carried out to examine contamination level for purpose of preservation of the pleasant underground environment. Three subway stations and three underground shopping centers in Seoul and two underground shopping centers in Busan were selected and surveyed by measuring gaseous pollutants $(SO_2,\; NO_2,\;CO,\;HC,\; HCHO,\;CO_2)$, dust, airborne microbes, and the other air condtions (temperature, humidity, air pressure, air flow, kata cooling power). These examined data were compared with four kinds of standard (building sanitation management, room air quality standards, occupational safety and health standards, ventilation equipment) as environmental hygiene.

  • PDF