• 제목/요약/키워드: on-off valves

검색결과 107건 처리시간 0.024초

고속 온.오프 전자밸브를 사용한 유압실린더 힘 제어계의 응답성 개선 (Response Improvement in Hydraulic Cylinder Force Control System by Using a High Speed On-Off Electro-Magnetic Valve)

  • 이일영;권정호;박정환
    • 유공압시스템학회논문집
    • /
    • 제1권4호
    • /
    • pp.15-21
    • /
    • 2004
  • High speed on-off electro-magnetic valves have been used for pressure control or flow control in automotive or construction machine servomechanisms. These systems require quicker valve switching speed to improve control preciseness. The authors designed and manufactured an electric valve driver with quick response characteristics by using 3 power source type valve driver concept. In experiments by using a hydraulic system incorporating the new valve driver, the new driver shortened the switching lag time from 5 ms to 1.3 ms. And also the new driver showed excellent position tracking control performances.

  • PDF

정밀 위치제어를 위한 공압 피스톤의 미소변위 이송방법 및 혼합 제어 알고리즘 개발 (Development of the Small-displacement-movement of a Pneumatic piston and the Hybrid Control Algorithm for Precision Position Control)

  • 노철하;김영식
    • 한국정밀공학회지
    • /
    • 제18권7호
    • /
    • pp.40-45
    • /
    • 2001
  • This paper proposes a methodology for the small-displacement-movement of a piston and develops a hybrid control algorithm for the precision position control of a pneumatic rodless cylinder. The pneumatic system uses the voltage-proportional solenoid valves to minimum valve switching since the on/off type valves are create diffculties for accurate position control and induce a lot of valve switching. For the accurate position control a methodology for the small-displacement-movement of the piston is developed and identified experimentally. The main consideration on the development of the hybrid control law is to eliminate a stick-slip phenomenon in the pneumatic control system. This paper addresses these critical issues and presents experimental results for the pneumatic control system.

  • PDF

Magnetoresistive and Pinning Direction Behaviors of Synthetic Spin Valves with Different Pinning Layer Thickness

  • Cho, Ho-Gun;Kim, Young-Keun;Lee, Seong-Rae
    • Journal of Magnetics
    • /
    • 제7권4호
    • /
    • pp.147-150
    • /
    • 2002
  • The pinning direction, the spin flop behaviors and the magnetoresistive properties in top synthetic spin valve structure [NiFe/CoFe/Cu/CoFe (t$_{p2}$)/Ru/CoFe (t$_{p1}$)/IrMn] were investigated. The magnetoresistive and pinning characteristics of synthetic spin valves strongly depended on the differences in the two pinning layer thickness, ${\Delta}t(=t_{p2}-t_{p1})$. In contrast to the conventional spin valves, the pinning direction (P1) was canted off with respect to the growth field axis with ${\Delta}t$. We found that the canting angle ${\Phi}$ had different values according to the annealing field direction and ${\Delta}t$. When the samples were annealed at above the blocking temperature of IrMn with zero fields, the canted pinned layer could be set along the growth field axis. Because the easy axis which was induced by the growth field during deposition is still active in all ferromagnetic layers except the IrMn at $250{^{\circ}C}$, the pinning direction could be aligned along the growth field axis, even in 0 field annealing.

차동PWM방식에 의한 유압실린더의 위치제어 (Position Control of a Hydraulic Cylinder by a Differential PWM Method)

  • 권기수;이창돈;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권4호
    • /
    • pp.54-69
    • /
    • 1991
  • This study deals with the position control of a hydraulic cylinder system operated by two port 3-way high speed solenoid valve in Pulse-Width-Modulation mode, instead of using conventional electro-hydraulic servovalve. Due to the complexity and the relatively poor reliability of the servovalve, an actuator using simpler and more study high speed solenoid valve will be presented. The high speed solenoid valve acts as converters of electronic pulse signal to hydraulic ones. It has been pointed out that there are practical problems to be solved in the PWM system, that is (1) accuracy of positioning control becomes considerably insufficient because the system is affected by on/off action of the solenoid valves, and (2) serious nonlinerality appears in the valve characteristics as a result of the switching behavior of the valves. As a method to overcome these defects, the differential PWM driving method of a hydraulic cylinder that improved the steady-state-error, flow rate nonlinearity in simple PWM, and the hydraulic hunting of dead time compensated-PWM driving is proposed in this study.

  • PDF

비례 모듈레이터 특성 (Experimental Characteristics of the Electro-Pneumatic Proportional Modulator)

  • 윤소남;최병오;김찬용;박평원;이경우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1784-1787
    • /
    • 2005
  • In this paper, proportional modulator which controls the second pressure of the pneumatic system was studied and proportional operating of modulator was gotten by two digital valves that have a fast dynamic characteristics and were controlled by PWM operating method. In order to more precision pressure control, this modulator consist of not only high speed two digital valves but also pressure sensor, measurement equipment and controller having a microprocessing function. In this study, for the development of the new proportional modulator, various research such as PWM control method, test equipment manufacturing, testing and evaluation were accomplished.

  • PDF

마이크로 솔레노이드의 해석 및 설계 (Analysis and Design of Micro Solenoid)

  • 전용식;배상규;김동수
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.14-20
    • /
    • 2006
  • Recently, the on-off solenoid valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for on-off solenoid valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate on-off solenoid valve using the analogy of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, flow field characteristics was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D simulation using distribution curve of the force by working the front poppet.

  • PDF

소형 어로 크레인의 동적 거동 특성에 관한 연구 (A Study on the Dynamic Behavior Characteristics of a Small Fishing Crane)

  • 이원섭;이대재
    • 수산해양기술연구
    • /
    • 제37권3호
    • /
    • pp.163-173
    • /
    • 2001
  • 연근해 어업의 조업 시스템을 개선하기 위한 연구의 일환으로 소형 어로 크레인을 설계, 제작하고, 크레인 암(arm)의 앙각 및 선회 조작에 따른 부하의 전후 및 좌우 흔들림과 부하장력의 변동을 측정하여 크레인의 동적 응답특성을 분석, 고찰한 결과는 다음과 같다. 1. 본 연구에서 설계, 제작한 어로 크레인의 능력은 2 T-M. 최대 작업 반경은 3.7m이고, 조작 방식으로 솔레노이드 밸브에 의한 수동 및 원격조작, 비례제어밸브에 의한 수동 및 비례조작, 컴퓨터에 의한 제어조작이 가능하여 어로작업을 효율적으로 수행하는데 널리 활용될 수 있을 것으로 판단된다. 2. 크레인의 앙각 제어 실린더(lifting control cylinder)의 단위 스트로크(stroke) 변화에 대한 크레인 암의 앙각 변화량은 약 $1.2^\circ$/cm이었고, 측정치와 계산치는 일치하는 경향 나타내었다. 3. 크레인 암의 전방에 위치한 부하를 솔레노이드 밸브 조작에 의해 수직으로 인양할 때, 맨 처음 나타나는 부하의 전후방향에 대한 흔들림 주기와 각도 변동폭은 각각 3.0sec, $\pm17.2^\circ$이었다. 또한, 크레인 암에 현수되어 있는 부하를 솔레노이드 밸브 조작에 의해 수평으로 이동시킬 때. 맨 처음 나타나는 부하의 좌우방향에 대한 흔들림 주기와 각도 변동폭은 각각 2.9 sec, $\pm11.0^\circ$이었다. 4. 크레인 암에 현수되어 있는 부하를 솔레노이드 밸브 조작에 의해 동시에 수직 및 수평으로 이동시킬 때, 크레인 암의 상승속도 및 선회속도는 각각 $4.46^\circ$/sec, $6.4^\circ$/sec이었다. 5. 크레인 암의 전방에 위치한 부하를 비례제어밸브 조작에 의해 수직으로 인양할 때, 맨 처음 나타나는 부하의 전후방향에 대한 흔들림 주기와 각도 변동폭은 각각 2.9sec,$\pm8.4^\circ$이었다. 또한, 크레인 암에 현수되어 있는 부하를 비례제어밸브의 조작에 의해 수평으로 이동시킬 때, 부하의 전후 및 좌우방향에 대한 흔들림이 거의 없어 비례제어밸브의 조작 변위량과 조작 속도를 적절히 조절하면 부하의 흔들림 현상을 대폭 감소시킬 수 있음을 알 수 있었다.

  • PDF

7mm폭의 Micro Valve 자장 및 유동특성 고찰 (An Investigation into Micro Valve Field and Flow Field Characteristic of 7mm Width)

  • 전용식;김동수;신동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.657-658
    • /
    • 2006
  • Recently, the micro on-off valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for micro valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate micro on-off valve using the analogy of equivalent magnetic circuit and Finite Element Method(FEM) respectively. In case of poppet, flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

양압측정 및 화학탐지 모듈을 적용한 화생방 방호시설의 가스차단밸브에 관한 연구 (Study on the Gas Tight Shut-off Valve of NBC Shelter using Positive Pressure Measurement and Chemical Detection Module)

  • 박형근
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.417-422
    • /
    • 2017
  • 대량살상무기를 이용한 전쟁 발발 시 가장 위협적인 것은 일반적으로 눈에는 보이지 않으면서 극소량으로도 사망에 이를 수 있다는 것이다., 군 당국은 화생방 오염상황 발생 시 전투원의 생존성을 보장하기 위해 개인 및 화생방대피분야에 대해 상당한 노력을 투입하고 있다. 따라서 본 논문에서는 화생방 방호시설에 사용되는 각종 차단밸브의 제어에 이용되는 양압측정을 위한 모듈과 화학탐지 모듈을 개발하였다. 또한, 수작업에 의한 제조 공정으로 품질의 균일성이 부족하고, 불량품 과다 및 제조 원가가 높은 단점을 개선할 수 있는 고성능 가스차단밸브를 개발하였으며, 여기에 양압측정 및 화학탐지 모듈을 적용하여 화생방방호시설의 제어에 사용하였다. 개발된 가스차단밸브는 규정풍속에서의 압력손실 28[Pa] 및 내부압력 30[kPa]에서 기밀특성을 유지하였다. 원격에서 측정된 양압에 따라 가스차단밸브의 제어가 가능하므로 향후 수입대체 및 국방관련 기술의 대외 독립성 확보가 가능할 것으로 기대된다. 또한 재래식 무기 및 핵폭발에 의한 폭풍압의 급격한 유입으로 인한 피해를 예방하기 위하여 화생방 방호시설의 외부와 연결된 모든 흡기구나 배기구에 설치하여 시설내의 인명 및 장비 등을 보호할 수 있다.

상수관 파괴시 관망의 부분적 격리를 고려한 피해범위 산정 (An evaluation of the pipe failure impact in a water distribution system considering subsystem isolation)

  • 전환돈
    • 한국수자원학회논문집
    • /
    • 제39권2호
    • /
    • pp.89-98
    • /
    • 2006
  • 기존의 상수관 파괴로 인한 피해 영역의 산정에서는 파괴된 관만을 피해영역으로 고려하였으나 이는 파괴된 관만이 차폐되었을 경우에만 정확하다 할 수 있다. 차폐에 이용되는 밸브의 배치에 따라 추가로 더 많은 관들이 파괴된 관과 함께 차폐가 될 수 있으며 Walski에 의하여 제안된 segment 개념으로 이러한 추가적인 관의 차폐를 고려할 수 있는 방법이 Jun에 의해서 개발되었다. 그러나, segment 개념으로 찾아질 수 있는 피해영역보다 더 많은 부분이 관 파괴의 영향을 받을 수 있으며, 이는 관들의 연결형상에 의한 차폐와 용수 수요지점에서 적정한 압력수두를 확보하지 못하여 발생하는 추가적인 피해에 기인한다 본 연구에서는 밸브의 위치에 따른 추가적인 피해영역과 함께 관들의 연결형상 그리고 압력수두에 따른 피해를 순차적으로 고려할 수 있는 방법을 제안하여 제안된 방법을 실제 상수관망에 적용하여 적용성을 검토한다 실제 상수관망에 적용한 결과 한 개의 상수관 파괴에 의한 피해 영역이 밸브위치와 용수노선의 설계에 따라 많은 지역에 피해를 발생시킬 수 있음을 보여 주고 있다. 따라서 본 연구에서 제안된 방법을 적용하여 산정된 상수관 파괴에 따른 피해영역이 현실을 정확히 반영함을 알 수 있었다.