• Title/Summary/Keyword: on-line test

Search Result 3,408, Processing Time 0.044 seconds

Evaluation of Flow Characteristics within In-Line Mixer for Water Treatment using CFD Technique (CFD모사 기법을 이용한 관내 혼화장치내 흐름 특성 평가)

  • Park, Dae-Jin;Park, Young-Oh;Park, No-Suk;Kim, Seong-Su;Wang, Chang-Kuen
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.351-358
    • /
    • 2008
  • The modified in-line mixer which was suggested in this study for small water treatment facilities was evaluated on the performance of coagulation. For the objectives of this research, computational fluid dynamics(CFD) simulation was applied for analysis of flow characteristics within the modified in-line mixer. For verifying the results of CFD simulation, wet tests for the pilot plant were conducted. The wet test was to measure the actual coagulant dispersion distribution on the overall cross-section at a distance of 5.5D from the chemical injection point. From the results of CFD simulation and wet test, it was shown that the coagulant dispersion within the modified in-line mixer was occurred more uniformly than within the existing PDM(Pump diffusion Mixer). The results have confirmed the modified in-line mixer had several advantages compared with the existing PDM in terms of dispersion efficiency.

Ultimate Strength of Concrete Barrier by the Yield Line Theory

  • Jeon, Se-Jin;Choi, Myoung-Sung;Kim, Young-Jin
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.1
    • /
    • pp.57-62
    • /
    • 2008
  • When the yield line theory is used to estimate the ultimate strength of a concrete barrier, it is of primary importance that the correct assumption is made for the failure mode of the barrier. In this study, a static test was performed on two full-scale concrete barrier specimens of Korean standard shape that simulate the actual behavior of a longitudinally continuous barrier. This was conducted in order to verify the failure mode presented in the AASHTO LRFD specification. The resulting shape of the yield lines differed from that presented in AASHTO when subjected to an equivalent crash load. Furthermore, the ultimate strengths of the specimens were lower than the theoretical prediction. The main causes of these differences can be attributed to the characteristics of the barrier shape and to a number of limitations associated with the classical yield line theory. Therefore, a revised failure mode with corresponding prediction equations of the strength were proposed based on the yield lines observed in the test. As a result, a strength that was more comparable to that of the test could be obtained. The proposed procedure can be used to establish more realistic test levels for barriers that have a similar shape.

Study on Development & Implementation of Online Generator Frequency Response Test (On-line 발전기 주파수응답시험 개발 및 적용에 관한 연구)

  • Oh, Chang-Soo;Kwak, Wol-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.48-49
    • /
    • 2006
  • Recently, Importance of Generator's Active/Reactive Power Control Capability is highly emphasized for prevention of Large Blackout. Especially, Generator's frequency Response Capability is important to the Power System Frequency Stability. This paper deals with the Development & Implementation of Each Generator Frequency Response Capability Test via the Injection of Artificial Frequency to the Online Generator. Actual On-line Generator's frequency Response Test was successfully implemented to 13 Generator having various fuel source.

  • PDF

A Study on the Stress Corrosion Cracking Behaviors for Weld Joint of Steel with Various pH Values in Synthetic Sea Water (인공해수의 pH에 따른 강 용접부의 응력 부식균열거동에 관한 연구)

  • 유효선;나의균;정세희
    • Journal of Welding and Joining
    • /
    • v.13 no.1
    • /
    • pp.78-88
    • /
    • 1995
  • This paper was performed to study the utility of the SP(small punch) test and the AE(acoustic emission) test in the evaluation of SCC(stress corrosion cracking) susceptibility for parent metal and bond line of HT80 steel-weld joint by SAW(submerged arc welding) with the various pH values. The loading rate used was 3*10$^{-4}$ mm/min and the corrosive environment used was synthetic sea water during the SP test and the AE test. According to the test results, the SCC susceptibility of the parent metal was increased in the order of pH6.0, pH8.2 and pH10.0. On the other hand, the bond line showed almost the same high SCC susceptibility in all pH concentrations. Synthetically, from the results of the SCC susceptibility, the macro- and micro-SEM observation, the microfracture behaviors by AE test and the relationship between SCC susceptibility and displacement at incipient failure, .delta.$_{i.f-AE}$, it can be concluded that the SP test and the AE test are the good test methods to evaluate the SCC susceptibility for parent metal and bond line of the weld joint with the change of environmental factors.

  • PDF

Informativeness and Consumer Misleading Potentialities on the Internet Shopping Mall Sites -The Study of Comparison between On-line Market Place and Integrated Internet Stores- (인터넷 쇼핑몰 사이트에서의 정보성과 소비자 오도가능성 - 온라인 마켓 플레이스와 인터넷 종합쇼핑몰의 비교 -)

  • Kim, So-Ra
    • Journal of Families and Better Life
    • /
    • v.26 no.1
    • /
    • pp.15-29
    • /
    • 2008
  • The study examined the characteristics of internet shopping mall sites including on-line market places and integrated internet stores from a perspective of consumer protection. Specifically, the study investigated 1) whether sufficient information is provided on the internet shopping mall sites, 2) whether shopping mall sites abide by internet advertising principles, and 3) specific examples of consumer misleading potentialities from internet shopping sites. Further, on-line market places and integrated internet stores were compared based on their informativeness and potential consumer misleading factors. Total 50 shopping mall sites were analyzed for examining the types of information provided and consumer misleading factors. To verify study questions, descriptive statistics were used. For comparison between on-line market places and integrated internet stores, Chi-square test and independent-sample t-test were employed. The results of this study were as the following: First, not a few of the internet shopping mall sites did not provided important information such as safety and warrantees. Second, important disclosures were not noticeable on the web pages and distracting factors were frequently used. Third, integrated internet stores were desirable compared to on-line marketplaces based on informativeness and consumer misleading potentialities. As the result of this study, internet shopping malls need to advised to provide sufficient information and reduce potential misleading factors.

Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility

  • Bae, Byoung-Uhn;Lee, Jae Bong;Park, Yu-Sun;Kim, Jongrok;Kang, Kyoung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2477-2487
    • /
    • 2021
  • To improve safety analysis technology for a nuclear reactor containment considering an interaction between a reactor coolant system (RCS) and containment, this study aims at an experimental investigation on the integrated simulation of the RCS and containment, with an integral effect test facility, ATLAS-CUBE. For a realistic simulation of a pressure and temperature (P/T) transient, the containment simulation vessel was designed to preserve a volumetric scale equivalently to the RCS volume scale of ATLAS. Three test cases for a steam line break (SLB) transient were conducted with variation of the initial condition of the passive heat sink or the steam flow direction. The test results indicated a stratified behavior of the steam-gas mixture in the containment following a high-temperature steam injection in prior to the spray injection. The test case with a reduced heat transfer on the passive heat sink showed a faster increase of the P/T inside the containment. The effect of the steam flow direction was also investigated with respect to a multi-dimensional distribution of the local heat transfer on the passive heat sink. The integral effect test data obtained in this study will contribute to validating the evaluation methodology for mass and energy (M/E) and P/T transient of the containment.

Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line (초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석)

  • Lim, Jae-Seop;Shin, Koo-Yong;Lee, Dong-Il;Ju, Mun-No;Yang, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

On-Line System for Partial Monitoring Discharge (온라인 부분방전 감시 시스템)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

Safety Assurance of Dropper Clamp in Overhead Catenary System(I) (전차선로 드롭바 클램프 안전성 확보(I))

  • Lee, Ki-Won;Cho, Yong-Hyeon;Park, Young;Min, Byung-Il;Kwon, Sam-Young;Seok, Chang-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.223-226
    • /
    • 2007
  • In the electrical railway, for the improvement of a train speed, it is necessary to study not only the dynamic behaviors of overhead catenary system but the fatigue behaviors of components for a safety assurance according to the increase of vibration level. One of the critical components in the system is a dropper. Therefore, the dynamic force acting on a dropper was measured in the Chungbuk Line and analyzed to figure out the dynamic characteristics the dropper. And in order to assure the safety of dropper clamp and cable, we proposed a test facility as well as test method based on the test results For the further study, we will measure the dynamic forces in the conventional line and high-speed line and make up the test condition, so that the safety of dropper clamps can be assured.

  • PDF

3-Dimensional Contour Line Algorithm (3차원 등가속도 처리에 관한 연구)

  • Choe, Heon-O;Lee, Seok-Sun
    • 한국기계연구소 소보
    • /
    • s.20
    • /
    • pp.13-20
    • /
    • 1990
  • An algorithm is presented for 3-dimensional contour lines with a hidden line removal ~technique developed by T.L. Janssen(l). Contour line algorithm on any 3-dimensional plane cutting solid body is also shown. NUFIG(2) algorithm is adopted for searching contour lines. Test problems show well-established contour lines on the surface and also on the cutting plane of the structure.

  • PDF