Seismic vulnerability and preservation of historical masonry monumental structures

  • Dogangun, Adem;Sezen, Halil
    • Earthquakes and Structures
    • /
    • v.3 no.1
    • /
    • pp.83-95
    • /
    • 2012
  • Seismic damage and vulnerability of five historical masonry structures surveyed after the 1999 Kocaeli and Duzce, Turkey earthquakes are discussed in this paper. The structures are located in two neighboring cities that have been struck by five very large ($M_s{\geq}7.0$) earthquakes during the $20^{th}$ century alone. Older masonry mosques with arches and domes and their masonry minarets (slender towers) were among the most affected structures in this highly seismic region. While some of the religious and historical structures had virtually no damage, most structures suffered significant damage or collapsed. In the city of Bolu, for example, approximately 600-year-old Imaret, 500-year-old Kadi, 250-year-old Sarachane, and 100-year-old Yildirim Bayezid mosques suffered substantial structural damage after the 1999 earthquakes. Another historical mosque surveyed in Duzce partially collapsed. Most common factors contributing to deterioration of historical structures are also presented. Furthermore, a brief overview of issues associated with analysis and modeling of historical masonry structures is provided.

Evaluation of Vibrations and Displacements of an Old Masonry Wall Induced by Soil-Cement Construction (소일-시멘트 시공 시 인접 석축 성벽 문화재에 발생한 진동 및 변위 평가)

  • Kim, Young-Seok;Choo, Jin-Hyun;Cho, Yong-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.957-962
    • /
    • 2010
  • Foundation systems in urban sites are often necessary to be constructed with little vibrations and displacements to surroundings. In order to assess applicability of a new foundation system for urban sites based on soil-cement mixing technique, vibrations and displacements induced by soil-cement construction process is evaluated. Soil-cement columns were constructed to reinforce soft ground near an old masonry wall in an urban redevelopment site, and the vibrations and displacements of the old masonry wall during construction were measured. Results indicate that the vibrations and displacements induced by soil-cement construction were little and not critical to the stability of the masonry wall.

  • PDF

Structural evaluation of Aspendos (Belkis) Masonry Bridge

  • Turker, Temel
    • Structural Engineering and Mechanics
    • /
    • v.50 no.4
    • /
    • pp.419-439
    • /
    • 2014
  • In this study, the structural performance of a seven span masonry arch bridge was evaluated. Investigations were performed on Aspendos (Belkis) Masonry Arch Bridge which was located on road of Aspendos Acropolis City in Antalya, Turkey. The old bridge was constructed in the early of fourth century AD, but it was exposed to the earthquakes in this region and the overloading by the river water. The old bridge was severely damaged and collapsed by probably an earthquake many years ago and a new bridge was then reconstructed on the remains of this old bridge by Seljuk in the 13th century. The bridge has also been affected from overflowing especially in the spring of each year, so some protective measures should be taken for this monumental bridge. Therefore, the structural performance under these loading has to be known. For this purpose, an initial finite element model was developed for the bridge and it was calibrated according to ambient vibration test results. After that, it was analyzed for different load cases such as dead, live, earthquake and overflow. Three load combinations were taken into account by deriving from these load cases. The displacements and the stresses for these combination cases were attained and compared with each other. The structural performance of Aspendos Masonry Arch Bridge was determined by considering the demand-capacity ratio for the tensile stress of the mortar used in Aspendos Masonry Arch Bridge. After these investigations, some concluding remarks and offers were presented at the end of this study.

Experimental and numerical analysis of the global behaviour of the 1:9 scale model of the Old Bridge in Mostar

  • Kustura, Mladen;Smoljanovic, Hrvoje;Nikolic, Zeljana;Krstevska, Lidija
    • Coupled systems mechanics
    • /
    • v.10 no.1
    • /
    • pp.1-19
    • /
    • 2021
  • Composite nature of the masonry structures in general causes complex and non-linear behaviour, especially in intense vibration conditions. The presence of different types and forms of structural elements and different materials is a major problem for the analysis of these type of structures. For this reason, the analysis of the behaviour of masonry structures requires a combination of experimental tests and non-linear mathematical modelling. The famous UNESCO Heritage Old Bridge in Mostar was selected as an example for the analysis of the global behaviour of reinforced stone arch masonry bridges. As part of the experimental research, a model of the Old Bridge was constructed in a scale of 1:9 and tested on a shaking table platform for different levels of seismic excitation. Non-linear mathematical modelling was performed using a combined finite-discrete element method (FDEM), including the effect of connection elements. The paper presents the horizontal displacement of the top of the arch and the failure mechanism of the Old Bridge model for the experimental and the numerical phase, as well as the comparison of the results. This research provided a clearer insight into the global behaviour of stone arch masonry structures reinforced with steel clamps and steel dowels, which is significant for the structures classified as world cultural heritage.

Modeling of Old Masonry Lining in Railroad Tunnels (철도터널내 조적식 라이닝의 모형화에 관한 연구)

  • Lee, J.S.;Shin, H.K.;Kim, M.I.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.3
    • /
    • pp.3-13
    • /
    • 2001
  • The behavior of the masonry lining is studied to gain basic information on how to reinforce the masonry tunnels. Apart from the previous works on the masonry structures, the multi-course masonry structure, realistic in field condition, is considered and the constitutive relationship of the masonry is, therefore, established. The design charts of the orthotropic material properties are proposed according to the stiffness ratio and the crack initiation and subsequent propagation model is also considered to model the brittle nature of the masonry. A numerical analysis on the masonry panel is investigated to verify the proposed model and future works of the masonry lining are briefly explained.

  • PDF

Effectiveness of steel wire mesh as a strengthening material for masonry walls: A review

  • Richard Badonbok Lyngkhoi;Teiborlang Warjri;Wanraplang Warlarpih;Comingstarful Marthong
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.2
    • /
    • pp.117-132
    • /
    • 2023
  • The most prevalent and oldest type of structure is unreinforced masonry (URM) structures; URM walls are still a widely used construction material in India and many other developing countries due to their simplicity, ease of construction, economic sustainability, and ability to be built with locally available materials. URM walls are significantly weak while carrying lateral loads. The poor performance of URM walls during earthquakes has necessitated investigating an effective method for strengthening a newly built masonry building or retrofitting an old structure. Wire mesh, being cost-effective and easily available, satisfies the requirements to strengthen new and old URM buildings. The use of wire mesh to strengthen and retrofit the URM structure is simple to use, quick to construct, and inexpensive, especially in developing nations where heavy machinery and highly qualified labour are lacking. The current paper reviews the effectiveness of steel wire mesh as a reinforcing material for enhancing masonry strength. The finding gave encouraging results for the field application of wire mesh.

A Study on Reinforcement Effect of Face Wall with Opening using Spiral Anchor (나선형철물을 사용한 치장벽체 개구부 보강 효과에 관한 연구)

  • Jung, Won-Chul;Hwang, Wan-Seon;Kwon, Ki-Hyuk
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.37-40
    • /
    • 2007
  • Although masonry buildings fell into disfavour in the 1990's because of factors such ac bricklayers' high labor costs, bad reputation of poorly constructed masonry, masonry face wall is still preferred in korea as well as in other countries for its decorative value. Recently may problems with masonry face wall with opening have been reported, including cracks, deflection, swelling and even wall collapse in old masonry buildings, that mainly induced from the corrosion of connecting materials. So, it is necessary to develop the effective and uncorrosion connector. Therefore, this study aims to investigate the structural performance of masonry face walls with opening constructed by new connectors, spiral stainless anchors and to provide basic data for the field application of this method. The specimen reinforced bed joint has maximum load and displacement any other specimens.

  • PDF

Seismic vulnerability assessment of masonry facade walls: development, application and validation of a new scoring method

  • Ferreira, Tiago M.;Vicentea, Romeu;Varum, Humberto
    • Structural Engineering and Mechanics
    • /
    • v.50 no.4
    • /
    • pp.541-561
    • /
    • 2014
  • This paper approaches the issue of seismic vulnerability assessment strategies for facade walls of traditional masonry buildings through the development of a methodology and its subsequent application to over 600 building facades from the old building stock of the historic city centre of Coimbra. Using the post-earthquake damage assessment of masonry buildings in L'Aquila, Italy, an analytical function was developed and calibrated to estimate the mean damage grade for masonry facade walls. Having defined the vulnerability function for facade walls, damage scenarios were calculated and subsequently used in the development of an emergency planning tool and in the elaboration of an access route proposal for the case study of the historic city centre of Coimbra. Finally, the methodology was pre-validated through the comparison of a set of results obtained from its application and also resourcing to a widely accepted mechanical method on the description of the out-of-plane behaviour of facade walls.

Nonlinear earthquake capacity of slender old masonry structures prestressed with steel, FRP and NiTi SMA tendons

  • Preciado, Adolfo;Ramirez-Gaytan, Alejandro;Gutierrez, Nayar;Vargas, David;Falcon, Jose Manuel;Ochoa, Gil
    • Steel and Composite Structures
    • /
    • v.26 no.2
    • /
    • pp.213-226
    • /
    • 2018
  • This paper focuses on the seismic protection of slender old masonry structures by the implementation of prestressing devices at key locations. The devices are vertically and externally located inside the towers in order to be reversible and calibrated. An extensive parametric study on a selected slender tower is carried out based on more than 100 nonlinear static simulations aimed at investigating the impact of different parameters on the seismic performance: (i) different prestressing levels; (ii) shape memory alloy superelasticity and (iii) changes in prestressing-forces in all the stages of the analysis until failure and masonry toe crushing. The tendon materials under analysis are conventional prestressing steel, fiber-reinforced polymers of different fibers and shape memory alloys. The parametric study serves to select the most suitable prestressing device and optimal prestressing level able to dissipate more earthquake energy. The seismic energy dissipation is evaluated by comparing the structural capacity curves in original state and retrofitted.

Stability Analysis and Design of Reinforced Masonry Walls (보강석축의 안정해석 및 설계)

  • Kim, Hong Taek;Kang, In Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.239-253
    • /
    • 1992
  • The masonry walls, having the characters of cheap construction materials and relatively easy construction, have been widely used in supporting slopes. However, the necessity of reinforcing methods to improve the stability of masonry walls has been continuously required due to the collapses taken place quite often. In the present study, a new method to improve the stability of masonry walls was developed based on the soil nailing system proven effective in strengthening the surrounding soils. The developed method could be used in reinforcing the old masonry walls structually unsafe as well as in constructing new masonry walls. The effects of pore water pressures due to heavy rainfalls were included in the developed method and also the chart practically applicable to design was presented, together with a design example.

  • PDF