• 제목/요약/키워드: oil leakage

검색결과 241건 처리시간 0.026초

ZnO양자점 기반 센서의 초고감도 수소 검지 특성 (Ultra Sensitive Detection of H2 in ZnO QD-based Sensors)

  • 이현숙;김원경;이우영
    • 센서학회지
    • /
    • 제29권2호
    • /
    • pp.105-111
    • /
    • 2020
  • Interest and demand for hydrogen sensors are increasing in the field of H2 leakage detection during storage/transport/use and detection of H2 dissolved in transformer oil for safety issues as well as in the field of breath analysis for non-invasively diagnosing a number of disease states for a healthy life. In this study, various ZnO-based sensors were synthesized by controlling the reduction in crystallite size, decoration of Pt nanoparticles, doping of electron donating atoms, and doping of various atoms with different ionic radii. The sensing response of the various prepared ZnO-based nanoparticles and quantum dots (QDs) for 10 ppm H2 was investigated. Among the samples, the smallest-sized (3.5 nm) In3+-doped ZnO QDs showed the best sensing response, which is superior to those in previously reported hydrogen sensors based on semiconducting metal oxides. The higher sensing response of In-doped ZnO QDs is attributed to the synergic effects of the increased number of oxygen vacancies, higher optical band gap, and larger specific surface area.

불순물 입자의 유형에 따른 내접기어 펌프에서의 마모열화 특성 연구 (A Study on the Effects of Contaminant Types on the Wear Degradation Characteristics in Internal Gear Pumps)

  • 신정훈;지경렬;김형의
    • Tribology and Lubricants
    • /
    • 제27권3호
    • /
    • pp.134-139
    • /
    • 2011
  • The mechanical equipments which are exposed to impure environment undergo significant reductions in their own lifetimes. Several environmental test procedures have been developed to analyze these phenomena. Moreover in the industry to require shorter development duration, accelerated life testers artificially add test containments into machines. In this research JIS Z 8901 test powder was added into internal gear pumps which are used as oil pumps in vehicles and thus the effects of the addition on the degradation of the pumps were examined. Three kinds of contaminants were selected. Two of the contaminants are identical in particle size but different in the composition of the ingredients. The other pair have identical ingredients and composition but different particle size. The quantity of contaminants was also an interesting factor in this study. The results show that each JIS contaminant caused notable degradation in the discharge flow characteristic of pumps while friction torque degradation did not have any tendency. Finally leakage rates were deduced and equivalent wear volume ratios were calculated.

가스배관과 철탑접지의 이격거리 관련 기준 (Standards of Distance between Gas Pipeline and Tower Ground)

  • 이현구;하태현;하윤철;배정효;김대경
    • 한국가스학회지
    • /
    • 제11권1호
    • /
    • pp.18-22
    • /
    • 2007
  • 전력선에 지락고장이 발생할 경우 대지로 유입된 고장전류에 의하여 인접한 배관에 아크 용융이 발생하면 가스폭발이나 기름유출과 같은 대형사고를 발생시킬 수 있으며, 배관의 유지 및 보수를 담당하는 작업자의 안전에도 위험을 초래할 수 있다. 본 논문에서는 대지를 통한 철탑과 배관 사이의 아크 발생에 대하여 알아보고, 국내외에서 사용되고 있는 철탑 인근에 매설된 배관의 이격거리 기준을 조사하였다.

  • PDF

CFD Approach on Gas Explosion for SIL in Gas Fuelled Ship

  • Kim, Ki-Pyoung;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.195-200
    • /
    • 2015
  • It is envisaged that the effect of increasingly stricter air emissions legislation implemented through IMO Annex VI and other local air quality controls, together with favorable financial conditions for the use of natural gas instead of liquid fuel oil as a bunker fuel, will see an increasing number of DF engine and single gas fuel engine applications to LNG carriers and other vessel types. As part of provision for the current international movements in the shipping industry to reduce GHG emission in air, new design concepts using natural gas as an alternative fuel source for propulsion of large commercial vessels, have been developed by shipyards and research institutes. In this study, an explosion analysis for a gas supply machinery room of LNG-fuelled container ship is presented. The gas fuel concept is employed for the high pressure ME-GI where a leakage in the natural gas double supply pipe to the engines is the subject of the present analysis. The consequences of a leak are simulated with computational fluid dynamics (CFD) tools to predict typical leak scenarios, gas cloud sizes and possible explosion pressures. In addition, capacity of the structure which is subject to explosion loads has been assessed.

임해지역의 모의 지하 비축 시설 주변에서 해수 침투에 의한 지하수 유동 특성 (Groundwater Flow Characteristics Affected by the Seawater Intrusion near Simulated Underground Storage Caverns in the Coastal Area)

  • 황용수;배현숙;서동일;김경수;김천수
    • 지질공학
    • /
    • 제9권1호
    • /
    • pp.17-29
    • /
    • 1999
  • 임해지역에 건설되는 지하 비축 기지 주변에서의 지하수 유동에 영향을 미치는 주요 요인들로는, 지형적인 영향, 공동 굴착으로 인한 영향 및 해수 침투에 따른 영향으로 대별된다. 본 논문은 모의 지하 원유 비축 기지 지역을 대상으로 이러한 현상에 의한 지하수 유동 특성 변화를 2차원 수치 모델로 해석하였다. 해석 결과 상기 3가지 요인 중 공동 굴착에 의한 영향이 가장 중요한 것으로 판명되었다. 이와 같은 조건에서 저장 공동으로부터 외부로의 지하수 유동 경로 해석이 상세히 수행되었다. 수치 모델링 결과 공동 굴착으로 인하여 공동 주변 지하수압에 심각한 변화가 일어났으나 이에 따라 지하수 유동 경로도 바뀌었다. 수벽공을 이용한 적절한 운영압을 적용함으로서 저장 공동에 비축된 유류의 누출을 저감할 수 있음을 보였다.

  • PDF

FMEA를 이용한 건설현장 전력설비의 위험성에 대한 정성적 평가 (Qualitative Assessment for Hazard on the Electric Power Installations of a Construction Field using FMEA)

  • 김두현;이종호
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.36-41
    • /
    • 2004
  • This paper presents an qualitative assessment for hazard on the electric power installations of a construction field using FMEL The power installations have the mission to maintain the highest level of service reliability on the works. The more capital the electric power invest the higher service reliability they plausibly will achieve. However, because of limited resources, how effectively budgets can be allocated to achieve service reliability as high as possible. The assessment typically generates recommendations for increasing component reliability, thus improving the power installation safety. The FMEA tabulates the failure modes of components and how their failure affects the power installations being considered. Tn order to estimate the risks of a failures, the FMEA presents criticality estimation or risk priority number using the severity, occurrence, and detectability. The results showed that the highest components of the risk priority number among components were condenser, transformer, MCCB and LA. And In case of the criticality estimation, the potential failure modes were abnormal temperature rise, insulation oil leakage, deterioration for the transformer, overcurrent for the MCCB and operation outage fir the LA.

보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정 (Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit)

  • 장지팡;김춘택;정헌술
    • 유공압시스템학회논문집
    • /
    • 제4권4호
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF

로터리 댐퍼의 토오크 특성에 관한 연구 (A Study on the Torque Characteristics of Rotary Dampers)

  • 이춘태
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권4호
    • /
    • pp.87-92
    • /
    • 2019
  • Rotary dampers are damping devices which provide high resistance to shaft rotation. Rotary dampers are being used in various areas to enable the gentle opening and closing of the rotation motion relative to home furniture, industry machinery and automotive parts. Rotary dampers can be installed directly at the rotating point of a various part and can achieve uniform, gentle movement which increases quality and value of products. And generally, the silicone fluid is used as the damping medium because of its stable viscous properties. The movement of these little decelerators can be achieved with a high viscosity of working fluid and throttles installed in the body of the rotary damper. The damping force can be achieved clockwise, anti-clockwise or in both directions according to the structure of the orifices or throttles. In this paper, the torque performances of the rotary damper containing air in the working fluid were studied. For this purpose, the torque characteristic of the rotary damper according to the variation of various operating conditions such as clearance of leakage, dimensions of groove orifice, content ratio of air, etc., were simulated with AMEsim software.

크롬 도금한 유압 실린더 로드와 시일 사이의 미끄럼접촉 해석 (Sliding Contact Analysis between Chromium Plated Hydraulic Cylinder Rod and Seals)

  • 박태조;김민규
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권1호
    • /
    • pp.10-15
    • /
    • 2018
  • The hydraulic cylinder seals are used not only to protect leakage of the working fluids but also to prevent incoming of foreign particles into the system. Chromium plating is generally applied to improve corrosion and wear resistance. It has been noticed that sealing surface damage occurs due to the hard foreign/wear particles contained in the hydraulic oil. In this study, a three-bodied sliding contact problem related with a PTFE seal, a spherical particle and chrome-plated steel substrate is modeled to investigate the relations to wear mechanism. Using the nonlinear finite element software, MARC/MENTAT, the deformed shapes, the von Mises and first principal stress distributions with plating thickness were compared. The sealing surface was mainly abraded by hard particles embedded in the seal. The plastic deformation of the steel substrate decreased with thicker plating. Hence it could be more effective to coat the sealing surface of a hydraulic cylinder with a hard material such as TiN, TiC and DLC.

765kV 신가평, 신태백 변전소 예방진단시스템 (Preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations)

  • 권동진;심응보;정길조;김범진;김종화;유연표;은종영;신한철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1694-1697
    • /
    • 2002
  • KEPCO is planing to adopt a preventive diagnostic system to obtain the reliability of transformer and GIS in 765kV substation. KEPRI has developed the preventive diagnostic system for 765kV substation since 1997. We used various sensors and fault detecting devices such as a dissolved gas analyzer in oil, a ultrasonic detector and LA leakage current detector, etc., and carried out adaptation tests at the both a laboratory and a site. We developed a data acquisition system, a communication control unit and a server system as well. Furthermore, monitoring program and diagnostic expert system were also developed. This paper describes the preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations which will be operated from 2004.

  • PDF