• Title/Summary/Keyword: oil drop

Search Result 222, Processing Time 0.026 seconds

The Study of Characteristics Evaluation for Bimorph PZT Cantilever and its Application (바이몰프 PZT 캔틸레버 특성평가 및 응용연구)

  • 김석삼;채영훈;권현규
    • Tribology and Lubricants
    • /
    • v.19 no.3
    • /
    • pp.133-138
    • /
    • 2003
  • The characteristics for bimorph PZT cantilever of laboratory-fabricated have been evaluated experimentally. The deflections of cantilever with PZT are result from a capillary force between a water drop and a tip of cantilever. The output voltage due to deflect cantilever are depend on the tip shape and thickness of cantilever. We applied a bimorph PZT cantilever to oil thickness measurement. This reasonable concept is that the output voltage be caused by different defected characteristics between oil and surface. Experimental results demonstrated that the high measurement accuracy of the oil film thickness is obtained from the probe.

A Study On the Application of VHVI Base Oil - Hydraulic Fluid for Construction Equipment (VHVI 기유의 제품 적용 기술에 관한 연구 - 건설 중장비용 유압유)

  • 권완섭;문우식;윤한희;김경웅
    • Tribology and Lubricants
    • /
    • v.20 no.1
    • /
    • pp.33-40
    • /
    • 2004
  • This study represents the newly advanced formulation of hydraulic fluids for extended drain interval and introduces the performance results of used oil samples from various excavators. The used oil samples, in this paper, show that there is a sharp change in viscosity drop and moderate additive depletion when viscosity index of hydraulic oil is very high. For the extension of hydraulic fluid life, it is necessary to improve the stability of viscosity and oxidation. New target properties from the used oil analysis were proposed for extended life. Performance of newly developed hydraulic oil based on used oil analysis is compared with previously used one. The properties of new formulation are the viscosity index of 140 and improved thermal stability consists of VHVI base oil. Field test results showed the possibility of extension of fluid life. Additionally, for development of high performance product, new required propertied and performances were discussed.

Air Jet Effect on Performance Improvement of Non-Contact Type Seals for Oil Mist Lubrication Systems (공기분사가 오일미스트 윤활 시스템용 비접촉 시일의 성능 향상에 미치는 영향)

  • Na, Byeong-Cheol;Jeon, Gyeong-Jin;Han, Dong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2159-2166
    • /
    • 2000
  • Recently, high performance machining center requires special type of sealing mechanism that prevent a leakage of oil jet or oil mist lubrication system. Sealing of oil-air mixture plays important r oles to have an enhanced lubrication for performance machining center. Current work emphasizes on investigations of the air jet effect on the protective collar type labyrinth seal. To improve sealing capabilities of conventional labyrinth seals, air jet is injected against the leakage flow. In this study, an adapted model is introduced to improve sealing capability of conventional non-contact type seals. It has a combined geometry of a protective collar type and an air jet type. Both of a numerical analysis by CFD (Computational Fluid Dynamics) and experimental measurements are carried out to verify sealing improvement. The sealing effects of the leakage clearance and the air jet magnitude aic studied in various parameters. Gas or liquid has been used as a working fluid for most of nori-contact types seals including the labyrinth seal. However, it is more reasonable to regard two-phase flows because oil mist or oil jet are used for high performance spindle's lubrication. In this study, working fluid is regarded as two phases that are mixed flow of oil and air phase. Both of turbulence and compressible flow model are also introduced in a CFD analysis to represent an isentropic process. Estimation of non-leaking property is determined by amount of pressure drop in the leakage path. Results of pressure drop in the experiment match reasonably to those of the simulation by introducing a flow coefficient. Effect of the sealing improvement is explained as decreasing of leakage clearance by air jetting. Thus, sealing effect is improved by amount of air jetting even though clearance becomes larger

Design and Performance Test of Plate Type ER-Valve (평판형 ER-Valve의 제작 및 성능실험)

  • 장성철;염만오
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.29-35
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-valves are measured with varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. If we allow the same electric field in the ER-Valve, we came to how that the pressure drop is effected by the electrode length and electrode width. When the strength of the electric field increased, the pressure drop happened big and the flow rate decreased.

A Study on Effects of Oil Aeration Level on Engine Lubrication System by using Computer Program (컴퓨터 프로그램을 이용한 엔진오일 내 공기함량 변화가 엔진윤활시스템에 미치는 영향 연구)

  • 전상명;박영환;장시열
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.198-208
    • /
    • 2001
  • A Parametric study based on a computer analysis of the lubrication system of a four-cylinder gasoline engine is illustrated. Through the parametric study, the effects of various aeration levels on the change of oil flow rate and pressure are investigated. Also, at high oil temperature and low engine speed, the effect of oil aeration level on oil flow characteristics in lubrication system is investigated. The illustrated results may give to designers the guide lines of oil aeration level for the safe design of engine lubrication systems in terms of minimum pressure at crank oil bore.

Experimental study on Effects of POE oil on R134a Evaporation Heat Transfer in Plate Heat Exchanger (판형열교환기에서 POE오일이 R134a 증발 열전달에 미치는 영향에 대한 실험적 연구)

  • Chang, Young Soo;Jang, Jae Kyoo;Kang, Byung Ha;Kim, Sukhyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.3
    • /
    • pp.255-262
    • /
    • 2014
  • To investigate the effect of oil on evaporation heat transfer of plate heat exchanger, evaporation heat transfer experiment was carried out using experimental apparatus for micro gear pumped R134a-oil circulation. By varying oil circulation rate of POE oil from 0 to 5%, evaporation heat transfer performance of plate heat exchanger was investigated. As OCR(Oil Circulation Ratio) increases, the evaporation heat transfer coefficient of R134a decreases and pressure drop increases. When the evaporating temperature is $30^{\circ}C$ and the refrigerant mass flow rate is 80 g/s, evaporation heat transfer rate decreases by 10 % and pressure drop increases by 10% at 2% of OCR condition.

Effects of Microstructure and Surface Oil Film on the Welding in Zr Electroplated steel (전기아연도금 강에서 미세조직 및 표면유막이 용접 spatter에 미치는 영향)

  • 최한철;최수찬;김광연;안덕수;김영우
    • Journal of the Korean institute of surface engineering
    • /
    • v.30 no.1
    • /
    • pp.13-22
    • /
    • 1997
  • In order to investigate the effects of microstructure Oil film on the welding spatter in Zn electroplated steel, Zn electroplated surface and layer structure with USS-Paddition was observed using XRD, XPS and optical microscopy. Wettability of water drop on the Zn electroplated steel surface was measured using Z.Mei model. Oil absorption test was carried out using Oil pen. Morphology of spot welding and spatter with USS-P addition, applied current, and oil-spray or oil-without was observed using SEM and optical microscopy. Surface morphology of Zn electroplated steel showed finer structure as USS-P content increased. Wettabiliy on the Zn electroplated surface decreased with increasing USS-P content. Size of welding trace increased and spatter occured arround the welding part as applied current increased, whereas spatter disappeared as USS-P content increased and disappeared in case of oil spraying on the Zn electroplated surface.

  • PDF

Effect of the lubrication oil on heat transfer and pressure drop characteristics of supercritical carbon dioxide in a microfin tube (마이크로핀관내 냉동기유가 초임계 이산화탄소의 열전달과 압력강하에 미치는 영향)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1440-1446
    • /
    • 2012
  • This paper presents an experimental study of heat transfer and pressure drop characteristics of supercritical carbon dioxide with PAG inside a horizontal microfin tube. Heat transfer coefficient and pressure drop gradients were measured at 10 MPa in pressure and 520 kg/$m^2s$ in mass flux with variation of PAG mass concentration from 0.06% to 2.26%. The tendencies of both heat transfer and frictional pressure drop characteristics show the same as those of pure $CO_2$ up to 0.3% in PAG mass concentration. In case of 2.26% in PAG mass concentration, measured heat transfer coefficients showed 50% lower than those of pure $CO_2$ near the pseudocritical temperature and measured frictional pressure drop gradients show 1.6 times higher in comparison with those of pure $CO_2$ at $60^{\circ}C$ in $CO_2$ bulk temperature.

Study on Performance Test of Plate Type ER-Valves (평판형 ER-Valve의 성능실험에 관한 연구)

  • Jang S.C.;Yum M.O.;Kim D.T.;Park J.B.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.321-324
    • /
    • 2002
  • Hydraulic valve control the pressure and the How of fluid by the hydraulic oil transfered from pump but the ER fluid consists of solid particles of micrometer in size and insulating oil so in the general hydraulic valve. We invented ER-Valve using ER fluid as working fluid. The ER fluid, working fluid of ER-Valve is a functional fluid to represent the feature of fluid according to strength of electric field. In this research we made our own 4 types of plate type ER-Valve which has same surface but different width and length and then we conducted performance test. We measured flow rate and pressure drop of fluid which is flowing in the ER-Valve according to the electric field strength to conduct this test. We modeling ER-Valve relating to ER-Valve system and yield shear stress according to the strength of electric field. We used the pressure drop according to the strength of electric field by differential pressure gauge in the our own made ER-Valve. This test reviewed experimental the special changes of ER-Fluid in the steady flow condition.

  • PDF

Emission Characteristics of Fine Particles, Vanadium and Nickel from Heavy Oil Combustion (중유 연소 시 발생하는 미세입자 및 니켈과 바나듐의 대기 중 배출특성)

  • Jang, Ha-Na;Kim, Sung-Heon;Lee, Ju-Hyung;Hwang, Kyu-Won;Yoo, Jong-Ik;Sok, Chong-Hui;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.353-360
    • /
    • 2006
  • This study identified a particle size distribution (PSD) of fine particulate matter and emission characteristics of V and Ni by the comparison between anthropogenic sources of oil combustion (industrial boiler, oil power plant, etc.) and lab-scale combustion using a drop-tube furnace. In oil combustion source, the mass fraction of fine particles (less than 2.5 micrometers in diameter) was higher than that of coarse particles (larger than 2.5 micrometers in diameter) in $PM_{10}$ (less than 10 micrometers in diameter) as like in lab-scale oil combustion. In addition to this, it was identified that ultra-fine particles (less than 0.1 micrometers in diameter) had a large distribution in fine particles. Toxic metals like V and Ni had large mass fractions in fine particles, and most of all was distributed in ultra-fine particles. Most of ultra-fine particles containing toxic metals have been emitted into ambient by combustion source because it is hard to control by the existing air pollution control device. Hence, we must be careful on these pollutants because it is obvious that these are associated with adverse health and environmental effect.