• Title/Summary/Keyword: off-time

Search Result 3,740, Processing Time 0.027 seconds

A Study on the MMPP Model Verification for the Real-time VBR Traffic of ATM Network (ATM망의 실시간 VBR 트래픽에 대한 MMPP 모델 적합성 검증 연구)

  • 정승국;이영훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8B
    • /
    • pp.699-706
    • /
    • 2003
  • This paper is to verify that 2-state MMPP Model conform to ATM VBR traffic characteristics by measuring and analyzing real-time VBR traffic in KT's ATM network. As a result, we validated the fact that real-time VBR traffic of ATM network cannot be apply to MMPP model and must be represented by previously general On-Off Model with characteristics as follows: arrival rate of On state (λ$_1$) is deterministic, arrival rate of Off state (λ$_2$) is zero, and two transition rate (T$_1$,T$_2$) is only random variable. As research results are to handle real traffic, these results can be used to all ATM network traffic model with traffic management function such as KT's ATM network.

Determination of Optimal Turn-off Angle for SRM Converter Using Self-Tuning Method (SRM 컨버터에서 자기동조 방식에 의한 턴오프 각의 결정)

  • 장도현;문진영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.418-425
    • /
    • 1998
  • In this paper. determination method of turn-off angle in the SRM drives is proposed to maintain the high torque at a any turn-on angle, which is realized by using selHuning control method, During the sampling time. a number of P pulses from encoder are checked by using one-chip microprocessor. and compared with pre-checked a number of pulses A After calculating difference between two data, the turn-off angle moves forward or backward direction by the self-tuning m method, As repeating such process, the optimal turn-off angle is determined and the maximum torque is maintained T Though experiments, it is observed that motor speed is almost maintained if turn-off angle is adjusted automatically by s selHuning method when turn-ηn angle is changed.

  • PDF

Real Time Temperature Distribution Measurement of a Microheater by Using Off-Axis Digital Holography (Off-Axis 디지털홀로그래피를 이용한 마이크로히터의 실시간 온도분포측정)

  • Tserendolgor, D.;Baek, Byung-Joon;Kim, Dae-Suk
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.106-113
    • /
    • 2011
  • We describe a single shot off-axis digital holography based on a Mach-Zehnder interferometic scheme for measuring temperature distribution of a microheater. The proposed scheme has the capability of reconstructing object phase image which is dependent of the temperature distribution in real time. Experimental results shows that there is a moderate linear relationship between the measured phase and temperature in the range of $20^{\circ}C$ to $60^{\circ}C$. We expect that the proposed system can provide a very reliable and fast solution in various surface temperature distribution measurement applications.

Control Signal Transmission Scheme Using OFDM PTS Embedded Side Information in Cognitive Radio System (무선 인지 시스템에서 OFDM PTS 임베디드 부가정보를 이용한 제어신호 전송 기법)

  • Jeong, Bong-Min;Sohn, Sung-Hwan;Jang, Sung-Jeen;Kim, Jae-Moung
    • Journal of Internet Computing and Services
    • /
    • v.12 no.2
    • /
    • pp.75-83
    • /
    • 2011
  • Wireless services and devices that use frequency increase more and more because of advancement of the industry. Therefore, the available spectrum band becomes increasingly insufficient. Cognitive Radio, which adaptively utilizes the vacant licensed spectrum band, is considered as an effective way to utilize the spectrum resource shortage. CR user should move from current allocated channel to vacant channel to avoid the interference to the primary user when the primary user appears in the current channel. In this case, CR system undergoes the break off time until handshake is completed. So, in order to guarantee the Quality of Service(QoS) of CR system, fast handshake method is required. In this paper, we propose the embedded control signal transmission technique to reduce the break off time. This method can transmit the control signals in data transmission period as well as the broadcasting period. Proposed method can improve the data throughput and decrease the break off time. Computer based simulation proves that our proposed scheme outperforms conventional one.

Characteristics of an 1.25 Gbps 850 nm Oxide VCSEL Transmitter Operating at Fixed Current over a Wide Temperature Range (넓은 온도 범위에서 고정 구동전류로 동작하는 1.25 Gbps 850 nm 산화형 VCSEL 송신기의 특성)

  • Kim, Tae-Ki;Kim, Tae-Yong;Kim, Sang-Bae;Kim, Sung-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.43-53
    • /
    • 2007
  • We have analyzed low current operation characteristics of a VCSEL transmitter operating at fixed Current over wide temperature range. Used 850 nm oxide VCSEL has low temperature dependence of the threshold current and $d^2I_{th}/dT^2$ is approximately $1.346\times10^{-4}mA/^{\circ}C^2$. We fixed on-current so that output power from the chip is 1 mW at $20^{\circ}C$ and investigated the turn-on, turn-off characteristics and eye-diagram of the 850 nm oxide VCSEL transmitter with varying ambient temperature and off-current. We measured rise time, fall time, extinction ratio and timing jitter by changing tile ambient temperature and off-current. With the fixed off-current of around $0.1\sim0.2mA$ lower than the lowest threshold current the transmitter successfully operated at 1.25 Gbps over a wide temperature range from $-20^{\circ}C$ to $80^{\circ}C$.

Real-time model updating for magnetorheological damper identification: an experimental study

  • Song, Wei;Hayati, Saeid;Zhou, Shanglian
    • Smart Structures and Systems
    • /
    • v.20 no.5
    • /
    • pp.619-636
    • /
    • 2017
  • Magnetorheological (MR) damper is a type of controllable device widely used in vibration mitigation. This device is highly nonlinear, and exhibits strongly hysteretic behavior that is dependent on both the motion imposed on the device and the strength of the surrounding electromagnetic field. An accurate model for understanding and predicting the nonlinear damping force of the MR damper is crucial for its control applications. The MR damper models are often identified off-line by conducting regression analysis using data collected under constant voltage. In this study, a MR damper model is integrated with a model for the power supply unit (PSU) to consider the dynamic behavior of the PSU, and then a real-time nonlinear model updating technique is proposed to accurately identify this integrated MR damper model with the efficiency that cannot be offered by off-line methods. The unscented Kalman filter is implemented as the updating algorithm on a cyber-physical model updating platform. Using this platform, the experimental study is conducted to identify MR damper models in real-time, under in-service conditions with time-varying current levels. For comparison purposes, both off-line and real-time updating methods are applied in the experimental study. The results demonstrate that all the updated models can provide good identification accuracy, but the error comparison shows the real-time updated models yield smaller relative errors than the off-line updated model. In addition, the real-time state estimates obtained during the model updating can be used as feedback for potential nonlinear control design for MR dampers.

Determining the Optimal Cooking Time for Cooking Loss, Shear Force, and Off-Odor Reduction of Pork Large Intestines

  • Kim, Sung-Su;Lee, Yee Eun;Kim, Cho Hyun;Min, Joong-Seok;Yim, Dong Gyun;Jo, Cheorun
    • Food Science of Animal Resources
    • /
    • v.42 no.2
    • /
    • pp.332-340
    • /
    • 2022
  • The objective of this study was to determine the optimal cooking time by considering the cooking loss, shear force, and off-odor reduction of pork large intestines. Commercial pork large intestines were purchased, quartered perpendicularly, and cooked in boiling water for 40, 120, 180, and 240 min. Cooking loss of the samples increased after 240 min of cooking (10.92, p<0.05) while shear force value was lower at 240 min (4.45) compared to that at other cooking times (p<0.001). The amount of major volatile organic compounds showed a decreasing trend with increasing cooking time. In particular, the amount of methyl pentanoate (17,528.71) and methyl isobutyrate (812.51), compounds with a relatively low odor threshold, decreased significantly after 120 min of cooking and no change was observed thereafter (p<0.05). In addition, the amount of 2-pentanol (3,785.65) and 1-propanol (622.26), possibly produced by lipid oxidation, significantly decreased at the same cooking time (p<0.001). In the principal component analysis, only the 40 min cooking time was significantly different from other cooking time by high amounts of 1-propanol, 2-pentanol, and methyl isobutyrate. In conclusion, in the present study, the optimal cooking time for pork large intestines was 120 min in terms of off-odor reduction, cooking loss, and shear force.

Designing for the Off-line UPS using SMB Flywheel Energy Storage System (초고속 플라이휠 에너지 저장시스템을 이용한 Off-line UPS 제작)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.689-692
    • /
    • 2000
  • This paper presents a designing for the Off-line UPS usig SMB Flywheel Energy Storage System. This described flywheel energy storage system is designed to replace of the conventional EMB(Electro Mechanical Battery) system. To realize the high efficiency and to minimize the torque ripple the waveform of the inverter output current is controlled to be sinusoidal. The actual performance of the Off-line UPS using flywheel energy storage system is described. The prototype device was manufactured, The experimental result has good characteristics at a time of power transition region and regeneration modes,

  • PDF

Off-line Visual Feedback Control of SCARA Robot Using Off Line Programming (오프라인 프로그래밍을 이용한 스카라 로봇의 비쥬얼 피드백제어)

  • 신행봉;이우송;이현철;한성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.235-240
    • /
    • 2004
  • The equipment of industrial robot in manufacturing and assembly lines has rapidly increased. In order to achieve high productivity and flexibility, it becomes very important to develop the visual feedback control system with Off-Line Programming System(OLPS). We can save much efforts and time in adjusting robots to newly defined workcells by using OLPS. A proposed visual calibration scheme is based on position-based visual feedback. The calibration program firstly generates predicted images of objects in an assumed end-effector position. The process to generate predicted images consists of projection to screen-coordinates, visible range test and construction of simple silhouette figures. Then camera images acquired are compared with predicted ones for updating position and orientation data. Computation of error is very simple because the scheme is based on perspective projection which can be also expanded to experimental results. Computation time can be extremely reduced because the proposed method does not require the precise calculation of tree-dimensional object data and image Jacobian.

  • PDF

Performance Analysis of the Multiplexer for Shaped Video Traffic Sources (쉐이퍼를 사용한 비디오 트래픽원의 다중화기 성능 분석)

  • Lee, S.C.;Hong, J.W.;Kim, C.S.
    • IE interfaces
    • /
    • v.18 no.4
    • /
    • pp.494-503
    • /
    • 2005
  • This paper considers the problem of performance analysis for the multiplexer, when homogeneous periodic on-off sources are statistically multiplexed. Periodic on-off source model is defined that on-period and off-period are repeated by once in a deterministic periodic time and in on-period, cell arrives with deterministic time interval. In order to reflect periodicity of source model, we consider two multiplexing situation, such as random multiplexing and synchronized multiplexing. In both case, we obtain the overload-period distribution in the multiplexer, and an approximate method using the overload period distribution is suggested for obtaining the CLP(Cell Loss Probability) in the buffer of the multiplexer. A numerical example using MPEG-I real traffic samples and the results are also presented.