• 제목/요약/키워드: off-pump

검색결과 301건 처리시간 0.02초

고압콘덴서 개폐시 발생하는 써지의 특성 분석 (Property Analysis for On/Off Surge of High-Voltage Condenser)

  • 홍성택;이은춘;신강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.235-237
    • /
    • 2002
  • Whenever the large-capacitor and high-voltage pump motor is opened and closed, the power factor improvement condenser and the low-voltage equipment are often damaged by the sparking and the on-off power serge. In order to find the reason and resolve the problem, we have installed a transition wave recorder for obtaining the transient on-off power serge wave and a power disturbance analyzer for long-time monitoring. In this way we measured and analysed the condition of the high-voltage pump motor whenever it is opened and closed.

  • PDF

연료 송출용 제트펌프 3차원 전산해석 모델 (Three Dimensional Simulation Model of Fuel Delivery Jet Pump)

  • 박다인;윤진원;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제28권3호
    • /
    • pp.308-314
    • /
    • 2017
  • Jet pump in automotive fuel tank module is used to deliver fuel to fuel pump so that the pump is operated without aeration in suction side. In this study, three dimensional simulation model of jet pump is developed to understand performance variation over design parameters. Performance of jet pump is also investigated experimentally in terms of operating pressures. The experimental data is used to verify the three dimensional simulation model of jet pump. Verification results show that the three dimensional simulation model of jet pump is about 1% error with experiment. The simulations are conducted in terms of throat ratio and primary flow induction angle. As the throat ratio is increased, the flux ratio is trade-off at 3 times of throat diameter. On the other hand, as primary flow induction angle is increased, vapor pressure inside the nozzle is decreased. In summary, the results show that liquid jet pump has to be optimized over design parameters. Additionally, high velocity of induced flow is able to evolve cavitation phenomena inside the jet pump.

심폐바이패스하의 심박동상태에서 시행한 관상동맥우회로술 ("On-Pump" CABG on the Beating Heart - Two case report -)

  • 신종목;김기봉
    • Journal of Chest Surgery
    • /
    • 제32권5호
    • /
    • pp.480-483
    • /
    • 1999
  • 심폐바이패스와 심정지액을 이용하여 심장을 완전히 정지시킨 상태에서 원위부 관상동맥 문합을 시행하는 방법이 현재 관상동맥우회술에서 널리 사용되고 있다. 하지만, 심정지액을 이용한 심정지하의 관상동맥우회술은, 특히 고위험군 환자에서 수술중 심근의 허혈성 손상을 완전히 배제하지는 못하고 있다. 이런 측면에서 볼 때, 심폐바이패스를 사용치 않는 방법이 관상동맥우회술중 심근의 허혈성 손상을 방지하고 심폐바이패스의 합병증을 줄이기 위한 이상적인 방법이라 할 수 있겠지만, 이는 기술적으로 항상 가능한 것은 아니다. 이에 저자들은 좌심실 구출률이 25%로 좌심실 기능 저하가 심했던 경우와, 경피적 관상동맥확장술 중에 심인성 쇼크가 초래된 경우 등의 고위험군 환자에서 시행한 심폐바이패스하의 심박동상태에서의 관상동맥우회술 2례를 보고하는 바이다

  • PDF

Centrifugal biomedicus pump의 임상 응용 (Clinical use of Centrifugal Biomedicus Pump)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제25권12호
    • /
    • pp.1550-1555
    • /
    • 1992
  • From June 1989 to July 1992, we used centrifugal Biomedicus pump[CBP] in 20 patients In 9 cases, CBP was used as ventricular assistance after heart surgery for those who could not be weaned off bypass even with intra-aortic balloon counter-pulsation and with maximal inotropic support In 8 patients, CBP was used as partial left heart bypass during repair of aortic aneurysms or congenital aortic anomalies. And in 3 patients, CBP was used as vena caval bypass during resection of renal cell carcinoma with tumor extension into the inferior vena cava. In 2 of 9 patients with ventricular assistance, they were weaned off the device successfully after 16 hours and 7 days respectively. But the patients died of intracranial hemorrhage and sepsis, 7 and 29 days after weaning from cardiac support, respectively. In all the patients who underwent aortic of vena caval surgery using CBP as shunt, there were no complications such as postoperative bleeding necessitating reoperation, renal failure or neurologic sequelae. In conclusion, the centrifugal type of ventricular assistance may be potentially life saving treatment modality in patients with severe postoperative low cardiac output syndrome. The CBP can be safely employed for resection of renal cell carcinoma with vena caval tumor extension and for repair of aortic aneurysms.

  • PDF

인공심폐기를 이용하지 않는 관상동맥우회술 시 요골동맥을 이용한 Cabrol 술식의 응용 (Cabrol Technique Application in Off-pump Coronary Artery Bypass Grafting Using Radial Artery)

  • 나찬영;오삼세;김수철;김재현;조원민;서홍주;이철;장윤희;강창현;임청;백만종;황성욱;최인석;김웅한;박윤옥;문현수;박영관;김종환
    • Journal of Chest Surgery
    • /
    • 제36권8호
    • /
    • pp.630-632
    • /
    • 2003
  • 인공심폐기를 사용하지 않는 관상동맥우회술에서 이식편의 근위부 문합을 상행대동맥에 시행하는 경우 상행대동맥의 조작으로 인한 공기나 대동맥조직, 죽종(atheroma) 등으로 인한 색전증과 대동맥 손상으로 유발되는 대동맥박리, 가성동맥류 등의 합병증을 유발할 수 있다 대동맥근부치환술 시 양측관상동맥의 재이식 시 도관을 사용하는 Cabrol 술식을 관상동맥우회술 시 적용하였다. 요골동맥이식편은 복재정맥과 다르게 혈관 내 판막이 없다는 이점을 고려하여 근위부 문합을 상행대동맥에 평행하게(side to side) 문합하여 하나의 근위부 문합으로 요골동맥이식편의 양측으로 혈류를 공급하는 Cabrol 술식을 이용하여 근위부 문합 수를 줄일 수 있으며 상행대동맥의 조작 수를 줄여 대동맥의 외상을 줄일 수 있다고 생각한다.

고압 터보펌프용 연료펌프의 수력설계 및 성능 평가 (Hydraulic Design and Performance Evaluation of a Fuel Pump for a High Pressure Turbopump System)

  • 최범석;윤의수;오형우
    • 한국유체기계학회 논문집
    • /
    • 제8권2호
    • /
    • pp.31-38
    • /
    • 2005
  • A low NPSH and high pressure fuel pump has been designed for a turbopump system. The fuel pump has an axial inducer and a centrifugal impeller. A meanline method has been established for the preliminary design and performance prediction of pumps at design or off-design points. KeRC(Kelyish Research Center) carried out a model testing of the fuel pump with water as a working fluid at the reduced speed. Predicted performances by the method are shown to be in good agreement with experimental results for cavitating and non-cavitating conditions. The established meanline method can be used for the performance prediction and preliminary design of high speed pumps which have a inducer, impeller and volute. In the current study, the three dimensional viscous flow in the fuel pump was investigated through numerical computation. A modified design of the fuel pump was generated to improve pump performance by utilizing CFD results. The modified fuel pump was experimentally tested by ROTEM and KARI(Korea Aerospace Research Institute). The measured non-cavitating and cavitating performance showed a good agreement with designed performance.

듀얼 위상 주파수 검출기를 이용한 차지펌프 PLL 설계 (Design of the Charge pump PLL using Dual PFD)

  • 이준호;이근호;손주호;김선홍;유영규;김동용
    • 대한전자공학회논문지SD
    • /
    • 제38권8호
    • /
    • pp.20-26
    • /
    • 2001
  • 본 논문에서는 위상획득과정과 동기과정에서의 trade-off를 향상시킨 듀얼 위상 주파수 검출기를 이용하여 차지펌프 PLL을 설계하였다. 제안된 듀얼 위상 주파수 검출기는 상승에지에서 동작하는 POSITIVE 위상 주파수 검출기와 하강에지에서 동작하는 NEGATIVE 위상 주파수 검출기로 구성되어있다. 또한 PLL에 사용된 차지펌프는 전류뺄셈회로를 이용하여 전류 부정합을 감소시켰으며, reference spurs와 전압제어발진기의 변동을 감소시킬수 있도록 구현하였다. 제안된 PLL의 동작특성은 0.25${\mu}m$ CMOS 공종 파라미터를 이용하여 SPICE 시뮬레이션을 통해 검증되었다.

  • PDF

Analysis of Risk Factors for Conversion from Off-Pump to On-Pump Coronary Artery Bypass Graft

  • Lim, Junghyeon;Lee, Won Yong;Ra, Yong Joon;Jeong, Jae Han;Ko, Ho Hyun
    • Journal of Chest Surgery
    • /
    • 제50권1호
    • /
    • pp.14-21
    • /
    • 2017
  • Background: Off-pump coronary artery bypass (OPCAB) is performed worldwide, but significant risks are associated with conversion to on-pump surgery. Therefore, we evaluated the composite outcomes between an OPCAB group and a conversion group. Methods: From January 2008 to December 2012, 100 consecutive patients underwent OPCAB at Hallym University Sacred Heart Hospital, of whom 84 underwent OPCAB without adverse events (OPCAB group), and 16 were converted to on-pump surgery (conversion group). Early morbidity, early and long-term mortality, and major adverse cardiac and cerebrovascular events (MACCEs) were the primary and long-term composite endpoints. Results: The mean follow-up period was $55{\pm}26months$, with 93% of the patients completing follow-up. The composite outcomes in the OPCAB and conversion groups were as follows: early morbidity, 2.3% versus 12.5%; early mortality, 4.7% versus 0%; long-term mortality, 14.3% versus 25.0%; and MACCEs, 14.3% versus 18.8%, respectively. No composite endpoints showed statistically significant differences. Preoperative acute myocardial infarction (AMI) was identified as an independent risk factor for conversion (p=0.025). Conclusion: The conversion group showed no statistically significant differences in early mortality and morbidity, MACCEs, or long-term mortality compared with the OPCAB group. The preoperative diagnosis of AMI was associated with an increased number of conversions to on-pump surgery.

아스피린과 플라빅스의 수술 전 지속적 사용이 무심폐기 하 관상동맥우회술에 미치는 영향 (Effects of Preoperative Continuous Use of Aspirin and Plavix in off-pump Coronary Artery Bypass Surgery)

  • 이기종;이교준;양홍석;안지영;유경종
    • Journal of Chest Surgery
    • /
    • 제39권1호
    • /
    • pp.48-55
    • /
    • 2006
  • 배경: 아스피린과 플라빅스는 관상동맥 환자들에게 가장 흔히 사용하는 항혈소판 제제이나 수술 후 출혈 성향의 증가에 대한 우려 때문에 수술 5일에서 7일 전에 복용을 중단하는 것이 일반적이다. 본 연구에서는 이들 약제들의 지속적 사용이 무심폐기 하 관상동맥우회 술(Off pump coronary artery bypass grafting, Off pump CABG) 후의 결과에 어떤 영향을 미치는지에 관하여 조사하였다. 대상 및 방법: 2004년 3월부터 2005년 2월까지 Off pump CABG를 시행 받은 123명의 환자들을 대상으로 하여 수술 전후에 아스피린과 플라빅스를 끊지 않고 지속적으로 사용한 군(n=45, 36.6$\%$)과 적어도 수술 1일 이전에 끊은 군(n=78, 63.4$\%$) 사이에 수술 전후 혈소판, 헤모글로빈/헤마토크리트 수치, 수술 후 출혈량, 도관 개통률, 수술 시간 등을 비교하였다. 또한 대상환자들을 수술 전에 아스피린을 1달 이상 사용했던 장기 사용군과 그렇지 않은 군으로 구분하여 상기 요소들을 비교하였다. 결과: 수술에 의한 사망은 없었으며 출혈에 관한 합병증으로는 출혈에 의한 재수술과 상부 소화관 출혈이 각각 1예씩 있었다. 지속적으로 사용한 군과 그렇지 않은 군의 비교에 있어서는 수술 직후와 수술 후 1, 2일의 혈소판 수치가 지속적 사용군에서 유의하게 낮았으나(p=0.02, p=0.002, p=0.021) 수술 후 출혈량, 수혈 빈도, 출혈 관련 합병증 및 도관의 개통률에는 차이가 없었다 아스피린을 1달 이상 사용한 장기 사용군의 경우 그렇지 않은 군에 비하여 수술 전후의 혈소판 수치가 지속적으로 낮았으나 출혈량, 수혈 빈도, 합병증 및 도관의 개통률에는 차이가 없었다. 결론: 아스피린과 플라빅스의 Off pump CABG 전후의 지속적 사용은 수술 후 일시적인 혈소판 수치의 감소를 초래할 수 있으나 수술 후 출혈량, 수혈 여부, 수술 시간, 출혈과 관련된 합병증 및 도관의 개통률에는 영향을 주지 않았다. 그러므로 Off pump CABG에 있어서 아스피린과 플라빅스는 수술 전까지 지속적으로 사용하여도 될 것으로 생각한다.

유량제어방식에 따른 태양열 급탕시스템의 열성능 평가 (Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.