• Title/Summary/Keyword: off-pump

Search Result 301, Processing Time 0.021 seconds

Voltage Sags Impact on CAR and SOR of HANARO

  • Kim, Hyung-Kyoo;Jung, Hoan-Sung;Wu, Jong-Sup
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.657-658
    • /
    • 2004
  • The reactor protection system (RPS) of HANARO is a safety class system. The reactor is tripped by dropping four shut off rods (SOR). The SOR system consists of a SOR, hydraulic pump, hydraulic cylinder, solenoid valves and a power supply unit which has the AC coil contactor as a switching component. The hydraulic pump lifts up the SOR. The SOR drops by loss of the hydraulic pressure in the hydraulic circuit at the occurrence of voltage sags or interruptions. From this experiment, we knew that the magnitude of the voltage sag which impacts on this system is 70V, 500msec. The reactor regulation system (RRS) of HANARO has four CARs which are connected to the driver through a magnetic clutch. The CAR drops by loss of electromagnetic force of the magnetic clutch when the deeper voltage sags to lower than 10V, 500msec.

  • PDF

Development of Stand-Alone Underground Water Pumping System using Photovoltaics System (태양광발전을 이용한 독립형 지하수 양수 시스템 개발)

  • Lee, Seung-Hun;Hwang, Jung-Hoon;Cho, Woon-Sik;Kim, Man-Il;Lee, Joon-Gee;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF

Design of CMOS RF Charge-Pump PLL using Dual PFD (듀얼 위상 주파수 검출기를 이용한 CMOS RF Charge-Pump PLL 설계)

  • 최현승;김종민;박창선;이준호;이근호;김동용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.10B
    • /
    • pp.1353-1359
    • /
    • 2001
  • 본 논문에서는 위상획득과정과 동기과정에서 trade-off 현상을 향상시킨 듀얼 위상 주파수 검출기를 제안하여 차지펌프 PLL을 설계하였다. 듀얼 위상 주파수 검출기는 상승에지에서 동작하는 POSITIVE 위상 주파수 검출기와 하강에지에서 동작하는 NEGATIVE 위상 주파수 검출기로 구성되어 있다. 제안한 차지펌프는 전류뺄셈회로를 이용하여 전류 부정합을 감소시켰으며, reference spurs와 전압제어발진기의 변동을 감소시킬 수 있도록 구현하였다. 제안한 차지펌프 PLL은 0.25$\mu\textrm{m}$ CMOS 공정을 사용하여 SPICE로 시뮬레이션 하였으며, 그 결과 1.6~1.85GHz의 넓은 동기범위를 나타내었다.

  • PDF

Experimental Study for the Prevention of Cavitation Damage in the Diesel Fuel Injection Pumps (디젤엔진 연료분사펌프 캐비테이션 손상 방지를 위한 실험적 연구)

  • Kim, Dong-Hun;Park, Tae-Hyung;Heo, Jeong-Yun;Ryu, Seung-Hyup;Kang, Sang-Lip
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.61-61
    • /
    • 2011
  • Cavitation phenomena during the injection process of the conventional fuel injection pump for a medium-speed diesel engine can cause surface damage with material removal or round-off on the plunger and barrel port and may shorten their expected life time. An experiment of flow visualization was carried out to investigate the main cause of these cavitation damages and find the prevention method. Experimental results of flow visualization show that these damages are mainly affected by fountain-like cavitation and jet-type cavitation generated before and after the end of fuel delivery process and therefore the prevention method was designed to control these cavitation flows. From the visualization and endurance test, it was proved that this method can effectively prevent cavitation damages by controlling cavitation flows.

  • PDF

A Study on the computer aided design for flow control valve of vane pump (베인 펌프용 유량 제어부의 전산설계에 관한 연구)

  • 이윤태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.555-560
    • /
    • 2000
  • The modeling and the numerical analysis are done so as to develop the Computer Aided Design program for the design of flow control valve attached to the vane pump. The factors affecting the flow rate characteristics, are analyzed by the experiments and the numerical methods. It is shown that the main factor affecting to the first control flow is the diameter of small rod of the spool, the main factor affecting to the second control flow is the diameter of big rod of the spool, the main factors affecting to the cut off are the main spring constant, the initial displacement of main spring and small diameter of the spool, and the dropping slope characteristics of flow rate are decided by the chamfer of spool and the dynamic characteristics of the spool.

  • PDF

A Study on the Reversal Flow Time due to Blackout (펌프장 정전시 역류발생시간에 관한 연구)

  • Park, Jong-Ho;Park, Han-Yung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.26-34
    • /
    • 2011
  • Waterhammer and slamming phenomena can occur when power is cut off due to reversal flow in pipeline and sudden close of check valve. Therefore analysis of reversal flow time, which means the time of reversal flow in pipeline due to pumping station blackout, is needed to protect facilities from waterhammer economically and efficiently. However systematic study on reversal flow time has not been done yet. So theory of reversal flow time analysis is proposed and verified with experiment using several parameters like pump specific speed, motor pole number, and characteristic curve of pipeline in this study.

Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas (혹한기 지역에서의 자연순환형 태양열 시스템 동파방지)

  • Kwon, Jae-Wook;Kim, Jong-Hyun;Hong, Hi-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

Effects of Preoperative Combined Antiplatelet Agents on the Postoperative Bleeding that Occurs during Off-pump Coronary Artery Bypass Surgery (무심폐기하 관상동맥우회수술에서 아스피린과 Clopidogrel의 수술 전 병합투여가 수술 후 출혈에 미치는 영향)

  • Choi, Kang-Joo;Seong, Hoo-Sik;Kae, Yoe-Kon
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.605-609
    • /
    • 2008
  • Background: It is well known that preoperative administration of combined antiplatelet agents can have an impact on the postoperative bleeding, the requirement for transfusion and the need for reexploration during on-pump coronary artery bypass surgery. Yet its effects have not been well evaluated in the case of off-pump coronary artery bypass surgery. Material and Method: We performed a retrospective study of nineteen patients who underwent OPCAB from March 2003 to December 2004. All the patients had taken antiplatelet agents until 12 hours before operation. The patients were divided into bo groups as an aspirin group and a combined (aspirin+clopidogrel) group. The perioperative platelet count, the hemoglobin level, the hematocrit, the prothrombin time and the aPTT were compared between both groups. The amount of postoperative bleeding, the transfusion requirement and the need for re-exploration to control bleeding were also compared between both groups. Result: There was no difference of operation time and the intraoperative ACT between the aspirin group and the combined group. The amount of blood loss through the chest tube for 24 hours was not different between the aspirin group $(697{\pm}271mL)$ and the combined group $(944{\pm}432mL)$. The number of patients who received blood transfusion was also not different between both groups. There was no patient who required reexploration for bleeding control in both groups. The perioperative hemoglobin level and hematocrit were also not different between both groups, but the postoperative hemoglobin level and hematocrit were decreased significantly in the group. Conclusion: The Preoperative combined antiplatelet (aspirin+clopidogrel) therapy group was not different from the aspirin group for the amount of postoperative bleeding, the amount of blood transfusion and the need for reexploration during off-pump coronary artery bypass grafting. This subject needs further evaluation because of small population in our study.

Oxygen Transfer Efficiencies of A Single Spiral Roll Aeration System by the Off-gas Method (Off-gas Analyzer를 이용한 하수처리장 단일선회류 방식 포기시스템 산소전달 효율의 평가)

  • Park, Bo Hwa;Ko, Kwang Baik;Park, Jae Han;Lim, Se Ho;Shin, Dong Rok;Yun, Hye Jung;Lee, Ji Young;Moon, Tae Hoon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.534-539
    • /
    • 2006
  • The supply of oxygen for aeration is the largest energy consumer at activated sludge wastewater treatment plants. Replacement of less efficient aeration systems with fine pore aeration devices can save up to 50 percent of aeration energy costs. The purpose of this study was the diagnosis and evaluation of a domestic wastewater aeration system by the off-gas method which had been studied by US EPA and ASCE. For this study, an off-gas analyzer and its hood were made to collect off-gas. Also, a vacuum pump was connected to the analyzer to make suction of off-gas. Experiments were conducted at a domestic activated sludge wastewater treatment plant which had a single spiral roll aeration system installed with P.E tube diffuser. Data on OTE(f), SOTE(pw), OUR, and air flow rate were obtained from these experiments. In case of replacing an aeration system, it is recommended that it should be replaced with perforated membrane disc or ceramic disc fine bubble diffusers installed in a full floor coverage or grid pattern.

Impact of High-Dose Statin Pretreatment in Patients with Stable Angina during Off-Pump Coronary Artery Bypass

  • Youn, Young-Nam;Park, Seong-Yong;Hwang, Yoo-Hwa;Joo, Huyn-Chul;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.44 no.3
    • /
    • pp.208-214
    • /
    • 2011
  • Background: Periprocedural treatment with high-dose statins is known to have cardioprotective and pleiotropic effects, such as anti-thrombotic and anti-inflammatory actions. We aimed to assess the efficacy of high-dose rosuvastatin loading in patients with stable angina undergoing off-pump coronary artery bypass grafting (OPCAB). Materials and Methods: A total of 142 patients with stable angina who were scheduled to undergo surgical myocardial revascularization were randomized to receive either pre-treatment with 60-mg rosuvastatin (rosuvastatin group, n=71) or no pre-treatment (control group, n=71) before OPCAB. The primary endpoint was the 30-day incidence of major adverse cardiac events (MACEs). The secondary endpoint was the change in the degree of myocardial ischemia as evaluated with creatine kinase-myocardial band (CK-MB) and troponin T (TnT). Results: There were no significant intergroup differences in preoperative risk factors or operative strategy. MACEs within 30 days after OPCAB occurred in one patient (1.4%) in the rosuvastatin group and four patients (5.6%) in the control group, respectively (p=0.37). Preoperative CK-MB and TnT were not different between the groups. After OPCAB, the mean maximum CK-MB was significantly higher in the control group (rosuvastatin group $10.7{\pm}9.75$ ng/mL, control group $14.6{\pm}12.9$ ng/mL, p=0.04). Furthermore, the mean levels of maximum TnT were significantly higher in the control group (rosuvastatin group $0.18{\pm}0.16$ ng/mL, control group $0.39{\pm}0.70$ ng/mL, p=0.02). Conclusion: Our findings suggest that high-dose rosuvastatin loading before OPCAB surgery did not result in a significant reduction of 30-day MACEs. However, high-dose rosuvastatin reduced myocardial ischemia after OPCAB.