• Title/Summary/Keyword: off angles

Search Result 216, Processing Time 0.023 seconds

Low-noise VLSI Implementation of Pipelined IIR Filters (파이프라인된 IIR 필터의 저잡음 VLSI구현)

  • 태기철;최정필;신승철;정진균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4B
    • /
    • pp.788-795
    • /
    • 2000
  • Scattered look-ahead pipelining method can be efficiently used for high sample rate or low-power applications of digital recursive filters. Although the pipelined filters are guaranteed to be stable by this method, these filters suffer from large round off noise when the poles are crowed within some critical regions. To avoid this problem, a low-noise implementation technique was proposed using constrained Remez exchange algorithm. By the constrained filter design approach, the desired filter spectrum is satisfied while some of the pole angles are constrained to avoid pole crowding within critical regions. In the proposed approach, to obtain improved spectrum characteristics or better round off noise properties, the radius of the angle-constrained pole is optimized depending on the direction of the pole movement.

  • PDF

Distribution of the Reynolds Stress Tensor Inside Tip Leakage Vortex of a Linear Compressor Cascade (I) - Effect of Inlet Flow Angle - (선형 압축기 익렬에서 발생하는 익단 누설 와류내의 레이놀즈 응력 분포 (I) -입구 유동각 변화의 영향-)

  • Lee, Gong-Hee;Park, Jong-Il;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.902-909
    • /
    • 2004
  • A steady-state Reynolds averaged Navier-Stokes simulation was conducted to investigate the distribution of the Reynolds stress tensor inside tip leakage vortex of a linear compressor cascade. Two different inlet flow angles ${\beta}=29.3^{\circ}$(design condition) and $36.5^{\circ}$(off-design condition) at a constant tip clearance size of $1\%$ blade span were considered. Classical methods of solid mechanics, applied to view the Reynolds stress tensor in the principal direction system, clearly showed that the high anisotropic feature of turbulent flow field was dominant at the outer part of tip leakage vortex near the suction side of the blade and endwall flow separation region, whereas a nearly isotropic turbulence was found at the center of tip leakage vortex. There was no significant difference in the anisotropy of the Reynolds normal stresses inside tip leakage vortex between the design and off-design condition.

Subspace-Based Adaptive Beamforming with Off-Diagonal Elements (비 대각요소를 이용한 부공간에서의 적응 빔 형성 기법)

  • Choi Yang-Ho;Eom Jae-Hyuck
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1A
    • /
    • pp.84-92
    • /
    • 2004
  • Eigenstructure-based adaptive beamfoming has advantages of fast convergence and the insentivity to errors in the arrival angle of the desired signal. Eigen-decomposing the sample matrix to extract a basis for the Sl (signal plus interference) subspace, however, is very computationally expensive. In this paper, we present a simple subspace based beamforming which utilizes off-diagonal elements of the sample matrix to estimate the Sl subspace. The outputs of overlapped subarrays are combined to produce the final adaptive output, which improves SINR (signal-to-interference-plus-noise ratio) comapred to exploiting a single subarray. The proposed adaptive beamformer, which employs an efficient angle estimation is very roubust to errors in both the arrival angles and the number of the incident signals, while the eigenstructure-based beamforer suffers from severe performance degradation.

Noise Reduction of a Underexpanded Supersonic Jet via Steady Blowing with Microjets (소형제트를 이용한 과소팽창 음속 제트에서의 소음저감)

  • Kim Jin-Hwa;Kim Jung Hoon;Yoo Jung Yul
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.747-750
    • /
    • 2002
  • An attempt to reduce supersonic Jet noise is carried out by using two steady microjets in a round jet. The jet is issued from a round sonic nozzle with an exit diameter of 10mm. Two micro-nozzles with an inside diameter of 1mm each are installed on the exit plane with an off-axis angle of $45^{\circ}$. Far-field noise was measured at a location 40 diameters off the jet axis. The angles between a microphone and the jet axis are $45^{\circ}\;and\;90^{\circ}$. For an injection rate less than $1{\%}$ of the main jet, screech tones were completely suppressed by the microjets. The reduction in the ovelall sound pressure levels were $2.4\;and\;2.7\;dB\;for\;90^{\circ}\;and\;45^{\circ}$ directions, respectively. The enhancement of mixing/spreading of the jet by the microjet was negligible. The reduction of noise is probably due to distorted shock cell structures and/or broken large scale vortical structures by the microjets.

  • PDF

On-Line Aircraft Parameter Identification Using Fourier Transform Regression With an Application to NASA F/A-18 Harv Flight Data

  • Song, Yongkyu;Song, Byungheum;Seanor, Brad;Napolitano, Marcello R.
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.327-337
    • /
    • 2002
  • This paper applies a recently developed on-line parameter identification (PID) technique to sets of real flight data and compares the results with those of a state-of-the-art off-line PID technique. The on-line PID technique takes Linear Regression from Fourier Transformed equations and the off-line PID is based on the traditional Maximum Likelihood method. Sets of flight data from the NASA F/A-18 High Alpha research Vehicle (HARV) circraft, which has been recorded from specifically designed maneuvers and used for our line parameter estimation, are used for this study. The emphasis is given on the accuracy and on-line measure of reliability of the estimates. The comparison is performed for both longitudinal and lateral-directional dynamics for maneuvers at angles of attack ranging u=20°through $\alpha$=40°. Results of the two estimation processes are also compared with baseline wind tunnel estimates whenever possible.

Study on performance prediction of centrifugal compressor with diffuser angle and rotational speed change (원심압축기의 디퓨져 각도조절과 회전수변경에 따른 성능예측에 관한 연구)

  • Park, Y.H.;Shim, Y.H.;Kim, C.S.;Cho, S.Y.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.55-62
    • /
    • 2012
  • Centrifugal compressors are widely used and each operating condition is different. However, it cannot be manufactured according to the every operating condition. In the this study, performance of compressor was evaluated with various rotational speeds of impeller and various stagger angles of diffuser in order to apply a typical model widely. A centrifugal compressor was designed and manufactured based on the design point. On this machines, an experiment was conducted and the performance was predicted at off-design point. The performance prediction was validated with the experimental result and the numerical result. Although the isentropic efficiency on the prediction was slightly lower than that on the experimental result due to the heat loss in the experiment, the pressure ratio was predicted well and also the predicted results were matched well with the numerical results. When the rotational speed of the impeller and the stagger angle of the diffuser were changed together, the compressor can be worked in the high efficiency region and avoided operating in the stall region.

Realization of Alignment-Free WPT System

  • Park, Byung-Chul;Son, Yong-Ho;Jang, Byung-Jun;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.329-331
    • /
    • 2014
  • A simple realization of an alignment-free wireless power transmission (WPT) system is presented in this letter. The WPT system consists of a transmitter with three reconfigurable modes corresponding to various controllable magnetic field directions in the azimuthal plane and an algorithm for the optimum mode selection carried by sensing the reflected voltage of the system. Twelve light emitting diodes (LEDs) are used to confirm the on- and off-state of LEDs powered wirelessly by the transmitter at every $15^{\circ}$ of the azimuthal plane. A criterion voltage from the reflected power of the system is found by using the correlation between the reflected voltage and the on- and off-state of the LEDs. Simply by continuous; monitoring of the voltage from the system, the system maintains power to the LEDs. The system is realized by MATLAB/Simulink and a National Instrument data acquisition device (DAQ) board. Measurements using the system show on-state LEDs in the azimuthal plane except at the angles of $60^{\circ}$, $75^{\circ}$, $180^{\circ}$, and $300^{\circ}$.

Detection of Intersection Points of Handwritten Hangul Strokes using Run-length (런 길이를 이용한 필기체 한글 자획의 교점 검출)

  • Jung, Min-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.887-894
    • /
    • 2006
  • This paper proposes a new method that detects the intersection points of handwritten Hangul strokes using run-length. The method firstly finds the strokes' width of handwritten Hangul characters using both horizontal and vertical run-lengths, secondly extracts horizontal and vertical strokes of a character utilizing the strokes' width, and finally detects the intersection points of the strokes exploiting horizontal and vertical strokes. The analysis of both the horizontal and the vertical strokes doesn't use the strokes' angles but both the strokes' width and the changes of the run-lengths. The intersection points of the strokes become the candidated parts for phoneme segmentation, which is one of main techniques for off-line handwritten Hangul recognition. The segmented strokes represent the feature for handwritten Hangul recognition.

  • PDF

Machinability in Oblique Powder Blasting of Glass (유리의 경사 미립분사가공시 가공성)

  • 박동삼;서태일
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.28-34
    • /
    • 2004
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for brittle materials such as glass, silicon and ceramics, capable of producing micro structures larger than 100${\mu}{\textrm}{m}$. In this study, we introduced oblique powder blasting, and investigated the effect of the impacting angle of particles, the scanning times and the stand-off distance on the surface roughness and the weight-loss rate of samples with no mask, and the wall profile and overetching of samples with different mask pattern in powder blasting of soda-lime glass. The varying parameters were the different impact angles between 50$^{\circ}$ and 90$^{\circ}$, scanning times of nozzle up to 40 and the stand-off distances 70mm and 100mm. The widths of mask pattern were 0.2mm, 0.5mm and 1mm. The powder was alumina sharp particles, WA #600. The mass flow rate of powder during the erosion test was fixed constant at 175g/min and the blasting pressure of powder at 0.2Mpa.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.